docs(changelog): Unreleased -- monitor logs (.MLG) and each unit's timeline

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R9LdWawLzUxwewZGA1
This commit is contained in:
serversdownandClaude Opus 5.5 committed 2026-11-16 11:08:30 -05:00
1 parent 03c272316f
commit ed4f3d2213
2 files changed
+70 -1

No files matched your search

+69
View File
@@ -135,6 +135,68 @@ All notable changes to seismo-relay are documented here.
- No schema change. - No schema change.
- The over-range flags are on the decoded event only: not stored in the - The over-range flags are on the decoded event only: not stored in the
DB, sidecar or `.h5` yet. DB, sidecar or `.h5` yet.
- **Monitor logs (.MLG): SFM reads them and keeps each unit's monitoring
timeline** (`feat/mlg-import`, merged 2026-11-16). Spec
`docs/superpowers/specs/2026-11-09-mlg-unit-timeline-design.md`.
- **Why (Brian, 2026-11-09):** every unit sends an `.MLG` at every call-in,
whatever its mode. A continuous-mode unit sends no event file on a quiet
day, so its `.MLG` is the only proof it was monitoring. That proof is what
a shot report attaches for a unit that did not trigger. Outage history is
the second use.
- **The format, measured** (reference D.4, rewritten):
- an 18-byte prefix, then length-led 292-byte records
- each record ends in a CRC-16/AUG-CCITT over `[0:288]`, little-endian:
3,329 / 3,329 records
- `minimateplus/mlg_file.py` reads it, checking every record's checksum,
and writes it: 16 / 16 real files rebuilt byte for byte
- the old unused writer in `blastware_file.py` (big-endian, a zero CRC
at the wrong end) is removed
- `minimateplus/crc.py` is the one CRC, now used by
`micromate/setup_block.py` too
- **Storage:** new tables `mlg_files` (one row per file received) and
`mlg_records` (one row per record, stored once). The original file is kept
under `<store>/<serial>/mlg/`.
- An empty file has no serial inside. It takes the longest known serial
its `<serial><counter>` name starts with, or is stored as unresolved,
never guessed.
- Only plain serials become directories.
- **The timeline** (`sfm/mlg_timeline.py`):
- **sessions:** how each ended, its events, and its trigger level as
logged
- **gaps and what each means:** call-in, scheduled off, lost power,
stopped by a person, memory full, no restart after a call-in, records
missing
- **clock steps:** the unit's clock steps back an hour at its first
call-in after daylight saving ends
- **call-ins:** delivered, no_file (a Modem Exit that left no file) and
nothing_new (an empty file)
- **"Was it monitoring at T"** answers monitoring / not_monitoring / unknown,
naming the records and file behind the answer. It never claims more than
the records show: a gap across a missing call-in number (files are
numbered) reads unknown.
- **Routes:** `POST /db/import/mlg_file`; `GET /db/units/{serial}/timeline`,
`/db/units/{serial}/monitoring_at`, `/db/mlg_records` and
`/db/mlg_files/{id}` (the original, for printing).
- **Tools:** `scripts/import_mlg_dir.py` (bulk import, with a dry run) and
`scratch/check_mlg_vs_events.py` (cross-check against the event files'
footers).
- **Measured on DL2's 1,273-file sample** (BE6907 and BE12844 from 2026,
BE8081 from 2018–19):
- 0 errors, 0 unresolved
- BE8081's 785 Event Recorded records match its 785 event files, both ways
- every recorded event falls inside a session
- two real outages: BE6907 recorded nothing for 14 days from 2026-10-07,
and BE8081 didn't restart after a failed call over Labor Day 2019
- ⚠ **Operational:**
- Two new tables are created on first start: no migration, no backfill,
no `TOOL_VERSION` bump (the event decode and the `.h5` files are
unchanged).
- Nothing arrives until `.MLG`s are imported. The watcher does not forward
them yet (`../series3-watcher`, Brian's call).
- DL2's full set (~86,000 files) loads with `scripts/import_mlg_dir.py`.
Load it from a robocopy copy: a Windows zip shifts summer file dates by
an hour.
- Terra-View shows none of it yet.
### Fixed ### Fixed
- **The mic's own range: a range-1 mic reads an eighth.** - **The mic's own range: a range-1 mic reads an eighth.**
@@ -236,6 +298,13 @@ All notable changes to seismo-relay are documented here.
- **Reference D.6, "Reading a mismatch":** 256, 4,096 and 65,536 mean a number - **Reference D.6, "Reading a mismatch":** 256, 4,096 and 65,536 mean a number
outgrew its 8-, 12- or 16-bit box. Every case so far is listed (Brian's outgrew its 8-, 12- or 16-bit box. Every case so far is listed (Brian's
observation, 2026-11-05). observation, 2026-11-05).
- **Reference D.4, rewritten:** the `.MLG` format, measured.
- Its framing, CRC and fields.
- How Blastware writes the files: one per call-in, no record repeated, and
a Modem Exit that is not a file's last record was a call that left no file.
- How a session appears, and the cross-check against the event files.
- The old D.4.1–D.4.3 (a 308-byte header, a CRC at each record's start) are
kept, marked retracted.
## v0.34.0 — 2026-11-04 ## v0.34.0 — 2026-11-04
+1 -1
View File
@@ -31,7 +31,7 @@ Read this first when picking the project back up.
3. switch ingest so reports are kept only for checking (retire the overlay) 3. switch ingest so reports are kept only for checking (retire the overlay)
4. stop the watchers forwarding reports 4. stop the watchers forwarding reports
- Until step 3, prod keeps the report as truth wherever one exists. - Until step 3, prod keeps the report as truth wherever one exists.
- **🔑 Monitor logs (.MLG) and each unit's timeline (2026-11-13, `feat/mlg-import`).** - **🔑 Monitor logs (.MLG) and each unit's timeline (merged to `dev` 2026-11-16; next release).**
- **What:** every unit sends an `.MLG` at every call-in, in every mode. SFM reads it - **What:** every unit sends an `.MLG` at every call-in, in every mode. SFM reads it
(`minimateplus/mlg_file.py`, reference D.4) and keeps each unit's monitoring timeline: (`minimateplus/mlg_file.py`, reference D.4) and keeps each unit's monitoring timeline:
sessions, gaps and what they mean, clock steps, and the call-ins, including calls that sessions, gaps and what they mean, clock steps, and the call-ins, including calls that