feat(sfm): Series-4 call-home state and audited enable/disable (phase 4)

- micromate: ENABLEABLE_WRITES gains 0x7E/0x7F (the call-home write and its
  confirm; spec row 9, enable/disable only); MicromateClient.get_call_home_content()
  returns the 126-byte 0x2C content.
- sfm/device_access: CallHomeState (serial, series, enabled, dial_string, detail
  with byte5 and the whole block); s4_call_home_state reads bit 0 of [5] and the
  dial string at [6:46]; s4_change_call_home runs the shared change core with
  micromate.writes.plan_call_home_enabled -- built from the read run_change made
  just before, and that same plan is the one sent.  A unit calling home (run
  state 0x03) is refused, nothing sent.  The read-back judges the edited bit
  only; the snapshot records both blocks and every changed offset -- [118:120]
  is unit-maintained and always moves.
- The write-ceiling tests take 0x71 (the setup write, phase 5) as their
  over-the-ceiling example now that 0x7E is enableable.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
This commit is contained in:
serversdownandClaude Opus 5.5 committed 2026-11-02 16:56:04 -05:00
1 parent 1dd5bfa464
commit eeb55effe9
7 files changed
+213 -13

No files matched your search

+5
View File
@@ -388,6 +388,11 @@ class MicromateClient:
# Anything else reads unknown(0x..): the safe default, which the change path refuses. # Anything else reads unknown(0x..): the safe default, which the change path refuses.
_RUN_STATES = {0x00: "idle", 0x02: "monitoring", 0x03: "calling_home"} _RUN_STATES = {0x00: "idle", 0x02: "monitoring", 0x03: "calling_home"}
def get_call_home_content(self) -> bytes:
"""The `0x2C` call-home block's 126-byte content (bit 0 of [5] is the
enable, [6:46] the dial string; [118:120] is unit-maintained)."""
return _content(self.protocol.read_call_home_config())
def read_run_state(self) -> MicromateRunState: def read_run_state(self) -> MicromateRunState:
"""`SUB 0x49` -> the unit's run state, with the in-call-home value kept """`SUB 0x49` -> the unit's run state, with the in-call-home value kept
(connect()'s `monitoring` bool flattens 0x03 into True).""" (connect()'s `monitoring` bool flattens 0x03 into True)."""
+3 -2
View File
@@ -84,8 +84,9 @@ READ_SUBS: Mapping[int, str] = MappingProxyType(_READ_SUBS)
# The write SUBs any code may transmit at all -- through MicromateProtocol.execute, # The write SUBs any code may transmit at all -- through MicromateProtocol.execute,
# one call at a time. Raising this is a spec change, reviewed like one: delete # one call at a time. Raising this is a spec change, reviewed like one: delete
# (0xA8/0xAA), raw file writes (0x8D/0x8E -- they could reach the modem # (0xA8/0xAA), raw file writes (0x8D/0x8E -- they could reach the modem
# settings) and 0xA2 never belong here without one. # settings) and 0xA2 never belong here without one. Phase 4 (2026-11-02) added
ENABLEABLE_WRITES = frozenset({0x96, 0x97}) # the call-home write and its confirm (spec row 9: enable/disable only).
ENABLEABLE_WRITES = frozenset({0x96, 0x97, 0x7E, 0x7F})
class OpcodeRefused(RuntimeError): class OpcodeRefused(RuntimeError):
+12
View File
@@ -69,6 +69,18 @@ class UnitSettings:
detail: Dict[str, Any] = field(default_factory=dict) detail: Dict[str, Any] = field(default_factory=dict)
@dataclass
class CallHomeState:
"""A unit's call-home switch, read by serial (phase 4). `enabled` is None when
the enable byte is not a value ever measured; `detail` keeps `byte5` and the
whole `block` (hex) as read."""
serial: str
series: int
enabled: Optional[bool]
dial_string: Optional[str]
detail: Dict[str, Any] = field(default_factory=dict)
@dataclass @dataclass
class EventRef: class EventRef:
"""One stored event, as listed. `event_id` is opaque: pass it back to """One stored event, as listed. `event_id` is opaque: pass it back to
+65 -3
View File
@@ -19,16 +19,17 @@ from typing import Any, Callable, Optional, TypeVar
from micromate.client import MicromateClient from micromate.client import MicromateClient
from micromate.opcodes import OpcodeRefused from micromate.opcodes import OpcodeRefused
from micromate.protocol import THOR_CHUNK_SIZE from micromate.protocol import THOR_CHUNK_SIZE
from micromate.writes import plan_start_monitoring, plan_stop_monitoring from micromate.writes import plan_call_home_enabled, plan_start_monitoring, plan_stop_monitoring
from minimateplus.transport import BaseTransport, SerialTransport, TcpTransport from minimateplus.transport import BaseTransport, SerialTransport, TcpTransport
from .errors import ( from .errors import (
AuditIncomplete, CallHomeInProgress, ChangeUnconfirmed, DeviceError, EventNotFound, AuditIncomplete, CallHomeInProgress, ChangeUnconfirmed, DeviceError, EventNotFound,
MalformedReply, StaleEvent, WrongUnit, translate, MalformedReply, StaleEvent, WrongUnit, translate,
) )
from .change import CALL_HOME_MESSAGE, monitoring_change, run_change from .change import CALL_HOME_MESSAGE, call_home_change, monitoring_change, run_change
from .events import iso_of, make_event_id, stamp_of from .events import iso_of, make_event_id, stamp_of
from .models import ChangeResult, DownloadedEvent, EventList, EventRef, UnitAddress, UnitInfo, UnitSettings, UnitStatus from .models import (CallHomeState, ChangeResult, DownloadedEvent, EventList, EventRef, UnitAddress,
UnitInfo, UnitSettings, UnitStatus)
from .series import normalise_serial from .series import normalise_serial
log = logging.getLogger("sfm.device_access") log = logging.getLogger("sfm.device_access")
@@ -370,3 +371,64 @@ def s4_change_monitoring(client: Any, serial: str, *, start: bool, dry_run: bool
# out. One transport read: RingWatchTransport over Tcp/SerialTransport, # out. One transport read: RingWatchTransport over Tcp/SerialTransport,
# each with a 10 ms read timeout, so it returns at once on a quiet line. # each with a 10 ms read timeout, so it returns at once on a quiet line.
pre_send=lambda: client.read_unsolicited()) pre_send=lambda: client.read_unsolicited())
def _dial_string(block: bytes) -> Optional[str]:
raw = bytes(block[6:46]).split(b"\x00", 1)[0]
return raw.decode("ascii", errors="replace") or None
def _changed_offsets(before: bytes, after: bytes) -> list:
return [i for i in range(max(len(before), len(after)))
if (before[i] if i < len(before) else None) != (after[i] if i < len(after) else None)]
def s4_call_home_state(client: Any, serial: str) -> CallHomeState:
"""Bit 0 of content[5] is the enable (UM12947 reads 0x05 / 0x04, UM20147 0x01)."""
block = client.get_call_home_content()
return CallHomeState(serial=serial, series=4, enabled=bool(block[5] & 0x01),
dial_string=_dial_string(block),
detail={"byte5": f"0x{block[5]:02X}", "block": block.hex()})
def s4_change_call_home(client: Any, serial: str, *, enabled: bool, dry_run: bool,
even_if_already: bool, audit: Any, address: UnitAddress,
caller: str, sleep: Callable[[float], None],
verify_timeout_s: float, verify_interval_s: float) -> ChangeResult:
"""Series-4 pieces for the shared core: read 0x2C, flip bit 0 of [5], send the
rest back byte for byte, re-read. The plan is built from the read run_change
made just before it (spec: build the plan on the same line, right before
sending), and that same plan is the one sent."""
reads: list = []
planned: list = []
def read_state() -> str:
if client.read_run_state().name == "calling_home":
return "calling_home"
block = client.get_call_home_content()
reads.append(block)
return "enabled" if block[5] & 0x01 else "disabled"
def describe_plan() -> dict:
planned[:] = [plan_call_home_enabled(reads[-1], enabled)]
return planned[0].describe()
def send() -> dict:
acks = client.protocol.execute(planned[0])
return {"subs": [f"0x{a.sub:02X}" for a in acks], "data": [bytes(a.data).hex() for a in acks]}
def snapshot() -> dict:
before, after = reads[0], reads[-1]
return {"before": before.hex(), "after": after.hex(),
"changed_offsets": _changed_offsets(before, after)}
return run_change(
kind=call_home_change(enabled), serial=serial, series=4, dry_run=dry_run,
even_if_already=even_if_already, audit=audit, address=address, caller=caller, sleep=sleep,
verify_timeout_s=verify_timeout_s, verify_interval_s=verify_interval_s,
read_serial=lambda: client.serial(refresh=True),
read_state=read_state, describe_plan=describe_plan, send=send,
is_refusal=lambda e: isinstance(e, OpcodeRefused),
is_ring=lambda e: isinstance(e, RingDetected),
pre_send=lambda: client.read_unsolicited(),
snapshot=snapshot)
+24 -1
View File
@@ -8,6 +8,7 @@ from __future__ import annotations
import copy import copy
import datetime import datetime
import json
from pathlib import Path from pathlib import Path
from micromate.models import MicromateDeviceInfo, MicromateEventRef, MicromateState from micromate.models import MicromateDeviceInfo, MicromateEventRef, MicromateState
@@ -16,6 +17,14 @@ from minimateplus.models import ComplianceConfig, DeviceInfo, Event, MonitorStat
SETUP_FIXTURE = Path(__file__).parent / "fixtures" / "micromate-setup" / "um20147_baseline.bin" SETUP_FIXTURE = Path(__file__).parent / "fixtures" / "micromate-setup" / "um20147_baseline.bin"
THOR_IDF = Path(__file__).parent / "fixtures" / "thor-idf" THOR_IDF = Path(__file__).parent / "fixtures" / "thor-idf"
THOR_WRITES = Path(__file__).parent / "fixtures" / "micromate-writes"
def um12947_call_home(enabled: bool = True) -> bytes:
"""UM12947's own 126-byte call-home content, as THOR read it (0x05 on, 0x04 off)."""
ex = json.loads((THOR_WRITES / "call-home-enable-disable.json").read_text())["exchanges"]
reads = [bytes.fromhex(e["response_data"])[11:] for e in ex if e["sub"] == 0x2C]
return next(r for r in reads if r[5] == (0x05 if enabled else 0x04))
from minimateplus.protocol import TimeoutError as mmp_TimeoutError # noqa: E402 from minimateplus.protocol import TimeoutError as mmp_TimeoutError # noqa: E402
@@ -237,15 +246,25 @@ class _FakeProtocol:
self._owner.executed.append(plan) self._owner.executed.append(plan)
if self._owner.execute_error is not None: if self._owner.execute_error is not None:
raise self._owner.execute_error raise self._owner.execute_error
for st in plan.steps:
if st.sub == 0x7E: # the unit stores the block and moves [118:120] itself
old = self._owner.call_home
self._owner.call_home = bytes(st.data[:118]) + bytes(~b & 0xFF for b in old[118:120]) \
+ bytes(st.data[120:])
return [type("Ack", (), {"sub": s.ack_sub, "data": bytes(11)})() for s in plan.steps] return [type("Ack", (), {"sub": s.ack_sub, "data": bytes(11)})() for s in plan.steps]
def read_call_home_config(self):
self._owner._step("read_call_home_config")
return bytes(11) + self._owner.call_home
class FakeMicromateClient(_Base): class FakeMicromateClient(_Base):
def __init__(self, serial="UM20147", *, monitoring=False, events=5, def __init__(self, serial="UM20147", *, monitoring=False, events=5,
unsolicited=b"", event_refs=None, run_states=None, unsolicited=b"", event_refs=None, run_states=None,
serial_reported=None, execute_error=None, **kw): serial_reported=None, execute_error=None, call_home=None, **kw):
super().__init__(**kw) super().__init__(**kw)
self.unit_serial = serial # not `serial`: that is the client's method self.unit_serial = serial # not `serial`: that is the client's method
self.call_home = um12947_call_home() if call_home is None else call_home
self.run_states = list(run_states) if run_states else [0x00] self.run_states = list(run_states) if run_states else [0x00]
self.serial_reported = serial if serial_reported is None else serial_reported self.serial_reported = serial if serial_reported is None else serial_reported
self.execute_error = execute_error self.execute_error = execute_error
@@ -272,6 +291,10 @@ class FakeMicromateClient(_Base):
self._step("serial") self._step("serial")
return self.serial_reported if refresh else self.unit_serial return self.serial_reported if refresh else self.unit_serial
def get_call_home_content(self) -> bytes:
self._step("get_call_home_content")
return self.call_home
def read_run_state(self): def read_run_state(self):
from micromate.models import MicromateRunState from micromate.models import MicromateRunState
self._step("read_run_state") self._step("read_run_state")
+96
View File
@@ -0,0 +1,96 @@
"""Series 4 call-home: read the enable bit and dial string, and change it through
the audited path (phase 4). The frames are micromate.writes' (equal to THOR's
for UM12947); [118:120] is unit-maintained and moves after any config write."""
from __future__ import annotations
import os
import sys
import pytest
sys.path.insert(0, os.path.dirname(os.path.dirname(os.path.abspath(__file__))))
from device_access_fakes import FakeMicromateClient, um12947_call_home # noqa: E402
from micromate.opcodes import ENABLEABLE_WRITES # noqa: E402
from micromate.writes import plan_call_home_enabled # noqa: E402
from sfm.device_access.errors import CallHomeInProgress # noqa: E402
from sfm.device_access.models import UnitAddress # noqa: E402
from sfm.device_access.s4 import s4_call_home_state, s4_change_call_home # noqa: E402
ADDR = UnitAddress(host="10.0.0.5", tcp_port=9034, port=None, baud=None)
class Audit:
def __init__(self):
self.rows = {}
def begin(self, **f):
cid = f"c{len(self.rows) + 1}"
self.rows[cid] = dict(f, outcome="pending")
return cid
def finish(self, cid, **f):
self.rows[cid].update(f)
def change(fake, *, enabled, dry_run=False, even_if_already=False):
return s4_change_call_home(fake, "UM20147", enabled=enabled, dry_run=dry_run,
even_if_already=even_if_already, audit=Audit(), address=ADDR,
caller="test", sleep=lambda s: None,
verify_timeout_s=3.0, verify_interval_s=1.0)
def test_call_home_writes_are_now_enableable():
assert {0x7E, 0x7F} <= ENABLEABLE_WRITES
def test_s4_call_home_state_reads_the_enable_bit_and_dial_string():
st = s4_call_home_state(FakeMicromateClient(), "UM20147")
assert (st.serial, st.series, st.enabled, st.dial_string) == ("UM20147", 4, True, "RADIO RING")
assert st.detail["byte5"] == "0x05"
assert st.detail["block"] == um12947_call_home().hex()
assert s4_call_home_state(FakeMicromateClient(call_home=um12947_call_home(False)), "UM20147").enabled is False
def test_s4_dry_run_shows_thors_frames():
fake = FakeMicromateClient()
r = change(fake, enabled=False, dry_run=True)
assert r.outcome == "dry_run"
assert r.plan["steps"] == plan_call_home_enabled(um12947_call_home(), False).describe()["steps"]
assert fake.executed == []
def test_s4_disable_sends_7e_7f_and_verifies():
fake = FakeMicromateClient()
r = change(fake, enabled=False)
assert (r.outcome, r.verified, r.state_after, r.action) == ("sent", "ok", "disabled", "disable call-home")
assert [st.sub for st in fake.executed[0].steps] == [0x7E, 0x7F]
assert fake.call_home[5] == 0x04
def test_s4_unit_maintained_bytes_do_not_make_a_mismatch():
r = change(FakeMicromateClient(), enabled=False)
assert r.verified == "ok"
snap = r.detail["snapshot"]
assert snap["changed_offsets"] == [5, 118, 119]
assert snap["before"] == um12947_call_home().hex() and snap["after"] != snap["before"]
def test_s4_no_change_while_calling_home():
fake = FakeMicromateClient(run_states=[0x03])
with pytest.raises(CallHomeInProgress):
change(fake, enabled=False)
assert fake.executed == []
def test_s4_already_enabled_is_skipped():
fake = FakeMicromateClient()
r = change(fake, enabled=True)
assert r.outcome == "skipped" and fake.executed == []
def test_s4_even_if_already_sends_the_no_op_write():
fake = FakeMicromateClient()
r = change(fake, enabled=True, even_if_already=True)
assert len(fake.executed) == 1
assert any("changes nothing" in w for w in r.plan["warnings"])
+8 -7
View File
@@ -16,7 +16,7 @@ from micromate.framing import FLAGS_THOR, build_request # noqa:
from micromate.opcodes import ENABLEABLE_WRITES, OpcodeRefused # noqa: E402 from micromate.opcodes import ENABLEABLE_WRITES, OpcodeRefused # noqa: E402
from micromate.protocol import ACK_DATA_LEN, TimeoutError as MmTimeout, UnexpectedResponse # noqa: E402 from micromate.protocol import ACK_DATA_LEN, TimeoutError as MmTimeout, UnexpectedResponse # noqa: E402
from micromate.writes import ( # noqa: E402 from micromate.writes import ( # noqa: E402
WritePlan, WriteStep, plan_call_home_enabled, plan_start_monitoring, WritePlan, WriteStep, plan_start_monitoring,
plan_stop_monitoring, plan_stop_monitoring,
) )
from test_micromate_protocol import frame, proto # noqa: E402 from test_micromate_protocol import frame, proto # noqa: E402
@@ -33,8 +33,9 @@ def _ready(responses):
return p, t return p, t
def test_the_ceiling_is_start_and_stop_only(): def test_the_ceiling_is_start_stop_and_call_home():
assert ENABLEABLE_WRITES == frozenset({0x96, 0x97}) # Phase 4 (2026-11-02) added the call-home write and its confirm.
assert ENABLEABLE_WRITES == frozenset({0x96, 0x97, 0x7E, 0x7F})
def test_execute_sends_exactly_the_plans_frame_and_returns_the_ack(): def test_execute_sends_exactly_the_plans_frame_and_returns_the_ack():
@@ -53,10 +54,10 @@ def test_permission_ends_with_the_call():
def test_a_plan_beyond_the_ceiling_is_refused_and_nothing_is_sent(): def test_a_plan_beyond_the_ceiling_is_refused_and_nothing_is_sent():
content = bytes(5) + b"\x05" + bytes(120) # 0x71 (the setup-block write) stays above the ceiling until phase 5.
p, t = _ready([]) p, t = _ready([])
with pytest.raises(OpcodeRefused, match="ceiling"): with pytest.raises(OpcodeRefused, match="ceiling"):
p.execute(plan_call_home_enabled(content, False)) p.execute(WritePlan("setup push", (WriteStep(0x71, 0x0000, bytes(4)),)))
assert t.written == [] assert t.written == []
@@ -110,7 +111,7 @@ def test_a_duck_typed_plan_is_refused():
def test_a_forged_step_in_a_real_plan_is_refused_at_the_step(): def test_a_forged_step_in_a_real_plan_is_refused_at_the_step():
p, t = _ready([]) p, t = _ready([])
plan = plan_start_monitoring() plan = plan_start_monitoring()
object.__setattr__(plan, "steps", (WriteStep(0x7E, 0),)) # subs now reads 0x7E too object.__setattr__(plan, "steps", (WriteStep(0x71, 0),)) # subs now reads 0x71 too
with pytest.raises(OpcodeRefused): with pytest.raises(OpcodeRefused):
p.execute(plan) p.execute(plan)
assert t.written == [] assert t.written == []
@@ -121,7 +122,7 @@ def test_a_forged_step_hidden_behind_a_good_plan_is_refused():
@property @property
def subs(self): def subs(self):
return frozenset({0x96}) return frozenset({0x96})
plan = Lying("x", (WriteStep(0x96, 0xFFFF), WriteStep(0x7E, 0))) plan = Lying("x", (WriteStep(0x96, 0xFFFF), WriteStep(0x71, 0)))
p, t = _ready([ACK_START]) p, t = _ready([ACK_START])
with pytest.raises(OpcodeRefused): with pytest.raises(OpcodeRefused):
p.execute(plan) p.execute(plan)