feat(sfm): Series-4 call-home state and audited enable/disable (phase 4)

- micromate: ENABLEABLE_WRITES gains 0x7E/0x7F (the call-home write and its
  confirm; spec row 9, enable/disable only); MicromateClient.get_call_home_content()
  returns the 126-byte 0x2C content.
- sfm/device_access: CallHomeState (serial, series, enabled, dial_string, detail
  with byte5 and the whole block); s4_call_home_state reads bit 0 of [5] and the
  dial string at [6:46]; s4_change_call_home runs the shared change core with
  micromate.writes.plan_call_home_enabled -- built from the read run_change made
  just before, and that same plan is the one sent.  A unit calling home (run
  state 0x03) is refused, nothing sent.  The read-back judges the edited bit
  only; the snapshot records both blocks and every changed offset -- [118:120]
  is unit-maintained and always moves.
- The write-ceiling tests take 0x71 (the setup write, phase 5) as their
  over-the-ceiling example now that 0x7E is enableable.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
This commit is contained in:
serversdownandClaude Opus 5.5 committed 2026-11-02 16:56:04 -05:00
1 parent 1dd5bfa464
commit eeb55effe9
7 files changed
+213 -13

No files matched your search

+5
View File
@@ -388,6 +388,11 @@ class MicromateClient:
# Anything else reads unknown(0x..): the safe default, which the change path refuses.
_RUN_STATES = {0x00: "idle", 0x02: "monitoring", 0x03: "calling_home"}
def get_call_home_content(self) -> bytes:
"""The `0x2C` call-home block's 126-byte content (bit 0 of [5] is the
enable, [6:46] the dial string; [118:120] is unit-maintained)."""
return _content(self.protocol.read_call_home_config())
def read_run_state(self) -> MicromateRunState:
"""`SUB 0x49` -> the unit's run state, with the in-call-home value kept
(connect()'s `monitoring` bool flattens 0x03 into True)."""
+3 -2
View File
@@ -84,8 +84,9 @@ READ_SUBS: Mapping[int, str] = MappingProxyType(_READ_SUBS)
# The write SUBs any code may transmit at all -- through MicromateProtocol.execute,
# one call at a time. Raising this is a spec change, reviewed like one: delete
# (0xA8/0xAA), raw file writes (0x8D/0x8E -- they could reach the modem
# settings) and 0xA2 never belong here without one.
ENABLEABLE_WRITES = frozenset({0x96, 0x97})
# settings) and 0xA2 never belong here without one. Phase 4 (2026-11-02) added
# the call-home write and its confirm (spec row 9: enable/disable only).
ENABLEABLE_WRITES = frozenset({0x96, 0x97, 0x7E, 0x7F})
class OpcodeRefused(RuntimeError):