feat(sfm): Series-4 call-home state and audited enable/disable (phase 4)

- micromate: ENABLEABLE_WRITES gains 0x7E/0x7F (the call-home write and its
  confirm; spec row 9, enable/disable only); MicromateClient.get_call_home_content()
  returns the 126-byte 0x2C content.
- sfm/device_access: CallHomeState (serial, series, enabled, dial_string, detail
  with byte5 and the whole block); s4_call_home_state reads bit 0 of [5] and the
  dial string at [6:46]; s4_change_call_home runs the shared change core with
  micromate.writes.plan_call_home_enabled -- built from the read run_change made
  just before, and that same plan is the one sent.  A unit calling home (run
  state 0x03) is refused, nothing sent.  The read-back judges the edited bit
  only; the snapshot records both blocks and every changed offset -- [118:120]
  is unit-maintained and always moves.
- The write-ceiling tests take 0x71 (the setup write, phase 5) as their
  over-the-ceiling example now that 0x7E is enableable.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
This commit is contained in:
serversdownandClaude Opus 5.5 committed 2026-11-02 16:56:04 -05:00
1 parent 1dd5bfa464
commit eeb55effe9
7 files changed
+213 -13

No files matched your search

+24 -1
View File
@@ -8,6 +8,7 @@ from __future__ import annotations
import copy
import datetime
import json
from pathlib import Path
from micromate.models import MicromateDeviceInfo, MicromateEventRef, MicromateState
@@ -16,6 +17,14 @@ from minimateplus.models import ComplianceConfig, DeviceInfo, Event, MonitorStat
SETUP_FIXTURE = Path(__file__).parent / "fixtures" / "micromate-setup" / "um20147_baseline.bin"
THOR_IDF = Path(__file__).parent / "fixtures" / "thor-idf"
THOR_WRITES = Path(__file__).parent / "fixtures" / "micromate-writes"
def um12947_call_home(enabled: bool = True) -> bytes:
"""UM12947's own 126-byte call-home content, as THOR read it (0x05 on, 0x04 off)."""
ex = json.loads((THOR_WRITES / "call-home-enable-disable.json").read_text())["exchanges"]
reads = [bytes.fromhex(e["response_data"])[11:] for e in ex if e["sub"] == 0x2C]
return next(r for r in reads if r[5] == (0x05 if enabled else 0x04))
from minimateplus.protocol import TimeoutError as mmp_TimeoutError # noqa: E402
@@ -237,15 +246,25 @@ class _FakeProtocol:
self._owner.executed.append(plan)
if self._owner.execute_error is not None:
raise self._owner.execute_error
for st in plan.steps:
if st.sub == 0x7E: # the unit stores the block and moves [118:120] itself
old = self._owner.call_home
self._owner.call_home = bytes(st.data[:118]) + bytes(~b & 0xFF for b in old[118:120]) \
+ bytes(st.data[120:])
return [type("Ack", (), {"sub": s.ack_sub, "data": bytes(11)})() for s in plan.steps]
def read_call_home_config(self):
self._owner._step("read_call_home_config")
return bytes(11) + self._owner.call_home
class FakeMicromateClient(_Base):
def __init__(self, serial="UM20147", *, monitoring=False, events=5,
unsolicited=b"", event_refs=None, run_states=None,
serial_reported=None, execute_error=None, **kw):
serial_reported=None, execute_error=None, call_home=None, **kw):
super().__init__(**kw)
self.unit_serial = serial # not `serial`: that is the client's method
self.call_home = um12947_call_home() if call_home is None else call_home
self.run_states = list(run_states) if run_states else [0x00]
self.serial_reported = serial if serial_reported is None else serial_reported
self.execute_error = execute_error
@@ -272,6 +291,10 @@ class FakeMicromateClient(_Base):
self._step("serial")
return self.serial_reported if refresh else self.unit_serial
def get_call_home_content(self) -> bytes:
self._step("get_call_home_content")
return self.call_home
def read_run_state(self):
from micromate.models import MicromateRunState
self._step("read_run_state")