merge: dev 9b458b5 into the parity branch (group A/B, #51 histogram timing)

Brings the checker's file-only decode work onto the parity branch so the
phase-5 bench runs on the code that will ship.  One conflict, the CRLF
Series-III reference changelog: both kept, phase 5's row numbered
'2026-11-03 (5)' above dev's (4)/(3)/(2).  test_event_ingest's live-
histogram dedup test asserted the stored row sits a second off the 0C
time -- the #51 bug, fixed on dev -- so its premise now reads the event's
own second; the dedup it tests still holds.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
This commit is contained in:
serversdownandClaude Opus 5.5 committed 2026-11-04 12:31:21 -05:00
commit f24913189b
31 files changed
+9577 -127

No files matched your search

+5 -4
View File
@@ -647,18 +647,19 @@ Implementation steps (concrete):
3. flip ingest so reports are kept only for checking (retire the overlay)
4. stop the watchers forwarding reports
**Done so far: 18 of 88 report fields match on every DL2 event.**
**Done so far: 47 of 88 report fields match on every DL2 event.**
- In v0.33.0: setup fields, notes, event type, histogram PVS, mic.
- On `dev`:
- the geophone range
- the job number
- histograms that decoded wrongly
- the footer: no more day-late histograms; every waveform time exact
- serial, version, calibration, battery, trigger source and levels, stop mode, mic type
- histogram interval detail: frequencies (#50 fixed), per-interval PVS, interval size, stop
- histogram start, stop, interval and peak times (#51 fixed); events keyed unit + time + type
- A Blastware report's dB/psi is its PC's preference, not anything in the event file: a carve-out.
**Next:**
- setup fields still unread: trigger, stop mode, units, serial, calibration, battery
- histogram interval detail: frequencies (#50), per-interval PVS, interval size, stop time
- histogram start times (#51)
- the values Blastware computes itself: ZC frequency, acceleration, displacement, time of peak
- the sensor check results
- the monitor log