Brings the checker's file-only decode work onto the parity branch so the phase-5 bench runs on the code that will ship. One conflict, the CRLF Series-III reference changelog: both kept, phase 5's row numbered '2026-11-03 (5)' above dev's (4)/(3)/(2). test_event_ingest's live- histogram dedup test asserted the stored row sits a second off the 0C time -- the #51 bug, fixed on dev -- so its premise now reads the event's own second; the dedup it tests still holds. Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com> Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
This commit is contained in:
commit
f24913189b
31 files changed
+9577
-127
No files matched your search
+132
-16
@@ -13,13 +13,16 @@ Pure: no I/O, and no import from `sfm/`.
|
||||
"""
|
||||
from __future__ import annotations
|
||||
|
||||
import datetime
|
||||
import math
|
||||
import re
|
||||
from dataclasses import dataclass
|
||||
from dataclasses import dataclass, field
|
||||
from typing import Callable, Optional, Sequence
|
||||
|
||||
from .bw_xml_report import XmlReport
|
||||
from .event_file_io import (_GEO_FS_BY_RANGE, _GEO_INT16_FS, _GEO_NORMAL_FS_INS, _MIC_PSI_PER_COUNT,
|
||||
from .event_file_io import (interval_times, _GEO_FS_BY_RANGE, _GEO_INT16_FS, _GEO_NORMAL_FS_INS, _MIC_PSI_PER_COUNT,
|
||||
decode_blastware_bytes)
|
||||
from .histogram_codec import half_period_to_hz
|
||||
from .models import Event
|
||||
from .waveform_codec import mic_count_to_db
|
||||
|
||||
@@ -30,6 +33,50 @@ GEO_IPS_PER_COUNT: float = _GEO_NORMAL_FS_INS / _GEO_INT16_FS
|
||||
_CHANNELS = ("Tran", "Vert", "Long", "MicL")
|
||||
_EVENT_TYPE = {"Waveform": "Full Waveform", "Histogram": "Full Histogram"}
|
||||
|
||||
# How Blastware prints the setup fields SFM reads (measured 2026-11-03).
|
||||
_MONTHS = ("January", "February", "March", "April", "May", "June", "July",
|
||||
"August", "September", "October", "November", "December")
|
||||
_TRIGGERED_BY = {0x0001: "Tran", 0x0002: "Vert", 0x0004: "Long", 0x0008: "MicL", 0x0200: "Manual"}
|
||||
_STOP_MODES = {0: "Fixed"}
|
||||
_MIC_TYPES = {2: "Linear Weighting"}
|
||||
_GEO_TRIGGERS, _MIC_TRIGGER = 0x07, 0x08
|
||||
# Blastware turns the mic trigger level from psi to dB with 6895 Pa per psi, not
|
||||
# 6894.757: 4,272 / 4,272 DL2 levels against 4,271 (the odd one 0.01 psi,
|
||||
# printed 130.8 dB(L), is 130.7498 at the exact constant).
|
||||
_TRIGGER_PA_PER_PSI = 6895.0
|
||||
|
||||
|
||||
def _setup_values(ev: Event) -> dict[str, object]:
|
||||
out: dict[str, object] = {}
|
||||
di = ev.device_info
|
||||
if di is not None:
|
||||
out["SerialNumber"] = di.serial
|
||||
fw = di.firmware_version or ""
|
||||
if di.dsp_version and fw.startswith("S33") and di.model:
|
||||
# "V 10.72-8.17 MiniMate Plus" from "10.72", "S338.17" and the model --
|
||||
# the only version in DL2, so the rule is proven for it alone.
|
||||
out["Version"] = f"V {di.dsp_version}-{fw[3:]} {di.model}"
|
||||
if di.calibration_date and di.calibrated_by:
|
||||
c = di.calibration_date
|
||||
out["Calibration"] = f"{_MONTHS[c.month - 1]} {c.day}, {c.year} by {di.calibrated_by}"
|
||||
out["BatteryLevel"] = ev.battery_volts
|
||||
out["Trigger"] = _TRIGGERED_BY.get(ev.triggered_by)
|
||||
out["RecordStopMode"] = _STOP_MODES.get(ev.record_stop_mode)
|
||||
out["Microphone"] = _MIC_TYPES.get(ev.mic_type)
|
||||
# dB or psi is Blastware's preference, not the unit's (carve-out
|
||||
# units-is-a-display-preference); SFM reports dB, the default.
|
||||
out["Units"] = "in/s and dB(L)" if ev.mic_type is not None else "in/s"
|
||||
# Blastware prints a trigger level only for a channel that is a trigger
|
||||
# source, and none for a Manual trigger.
|
||||
src, manual = ev.trigger_sources or 0, ev.triggered_by == 0x0200
|
||||
if src & _GEO_TRIGGERS and not manual:
|
||||
out["GeoTriggerLevel"] = ev.trigger_level_geo
|
||||
if src & _MIC_TRIGGER and not manual and ev.trigger_level_mic_psi:
|
||||
psi = ev.trigger_level_mic_psi
|
||||
out["MicTriggerLevel psi(L)"] = psi
|
||||
out["MicTriggerLevel dB(L)"] = 20 * math.log10(psi * _TRIGGER_PA_PER_PSI / 2e-5)
|
||||
return out
|
||||
|
||||
|
||||
@dataclass
|
||||
class SfmSide:
|
||||
@@ -40,6 +87,27 @@ class SfmSide:
|
||||
channels: list[str] # channels with decoded data, in Tran/Vert/Long/MicL order
|
||||
counts: dict[str, list[int]] # waveform samples or histogram interval peaks
|
||||
geo_ips_per_count: float = GEO_IPS_PER_COUNT # at the event's range, as SFM read it
|
||||
# interval column -> SFM's value per interval (a number, or Blastware's word)
|
||||
interval_values: dict[str, list[object]] = field(default_factory=dict)
|
||||
interval_times: Optional[list[str]] = None # each interval's printed time
|
||||
|
||||
|
||||
def interval_frequency(halfp: int, sample_rate: int) -> object:
|
||||
"""An interval's frequency as Blastware prints it: "N/A" for a half-period
|
||||
of 0, ">100" (">200" at 2048 sps) at 5 samples or fewer, "<1.0" below 1 Hz,
|
||||
else (sample rate / 2) / half-period in Hz. Measured on ~3.1 M DL2 cells,
|
||||
2026-11-03 (#50: the rate, not a fixed 512)."""
|
||||
if halfp == 0:
|
||||
return "N/A"
|
||||
hz = half_period_to_hz(halfp, sample_rate)
|
||||
if hz is None:
|
||||
return f">{round(100 * sample_rate / 1024)}"
|
||||
return "<1.0" if hz < 1.0 else hz
|
||||
|
||||
|
||||
def _interval_size(seconds: int) -> str:
|
||||
n, unit = (seconds // 60, "minute") if seconds % 60 == 0 else (seconds, "second")
|
||||
return f"{n} {unit}{'' if n == 1 else 's'}"
|
||||
|
||||
|
||||
def sfm_side(raw: bytes) -> SfmSide:
|
||||
@@ -72,6 +140,32 @@ def sfm_side(raw: bytes) -> SfmSide:
|
||||
if counts["MicL"]:
|
||||
values["MicLPSPL dB(L)"] = mic_count_to_db(max(abs(c) for c in counts["MicL"]))
|
||||
values["MicLPSPL psi(L)"] = pv.micl if pv is not None else None
|
||||
values.update(_setup_values(ev))
|
||||
if ev.stop_time is not None:
|
||||
values.update(HistogramStopDate=ev.stop_time.strftime("%Y-%m-%d"),
|
||||
HistogramStopTime=ev.stop_time.strftime("%H:%M:%S"))
|
||||
if ev.histogram_interval_sec:
|
||||
values["IntervalSize"] = _interval_size(ev.histogram_interval_sec)
|
||||
interval_values: dict[str, list[object]] = {}
|
||||
if ev.interval_half_periods and ev.sample_rate:
|
||||
for ch, hps in ev.interval_half_periods.items():
|
||||
interval_values[f"{ch} Freq Hz"] = [interval_frequency(h, ev.sample_rate) for h in hps]
|
||||
if ev.interval_pvs:
|
||||
interval_values["Geo PVS in/s"] = list(ev.interval_pvs)
|
||||
times = None
|
||||
n = len(counts["Tran"])
|
||||
if ev.record_type == "Histogram" and ts is not None and ev.histogram_interval_sec and n:
|
||||
start = datetime.datetime(ts.year, ts.month, ts.day, ts.hour, ts.minute, ts.second)
|
||||
ends = interval_times(start, ev.histogram_interval_sec, ev.stop_time, n)
|
||||
times = [t.strftime("%Y-%m-%d %H:%M:%S") for t in ends]
|
||||
# A peak's date and time are those of the interval holding it (first).
|
||||
for tag, series in (("TranPeak", counts["Tran"]), ("VertPeak", counts["Vert"]),
|
||||
("LongPeak", counts["Long"]), ("MicL", counts["MicL"]),
|
||||
("PeakVectorSum", ev.interval_pvs)):
|
||||
if series and len(series) == n:
|
||||
j = max(range(n), key=lambda q: abs(series[q]))
|
||||
values[f"{tag}Date"] = ends[j].strftime("%Y-%m-%d")
|
||||
values[f"{tag}Time"] = ends[j].strftime("%H:%M:%S")
|
||||
|
||||
return SfmSide(
|
||||
event=ev,
|
||||
@@ -82,6 +176,8 @@ def sfm_side(raw: bytes) -> SfmSide:
|
||||
channels=[ch for ch in _CHANNELS if counts[ch]],
|
||||
counts=counts,
|
||||
geo_ips_per_count=_GEO_FS_BY_RANGE.get(ev.geo_range, _GEO_NORMAL_FS_INS) / _GEO_INT16_FS,
|
||||
interval_values=interval_values,
|
||||
interval_times=times,
|
||||
)
|
||||
|
||||
|
||||
@@ -144,10 +240,12 @@ def _mic_converter(ref: XmlReport) -> Optional[Callable[[int], float]]:
|
||||
def _compare_scalar(tag: str, printed: str, sfm: SfmSide, ref: XmlReport) -> FieldResult:
|
||||
if not printed.strip() or printed.strip() == "N/A":
|
||||
return FieldResult(tag, "no_reference", printed, None)
|
||||
if tag == "MicLPSPL":
|
||||
units = ref.event_units or ""
|
||||
key = ("MicLPSPL dB(L)" if "dB(L)" in units else
|
||||
"MicLPSPL psi(L)" if "psi(L)" in units else None)
|
||||
if tag in ("MicLPSPL", "MicTriggerLevel"):
|
||||
# A printed value that states its unit is compared in that unit:
|
||||
# K441LA17.IN0W's Units say psi(L), its MicTriggerLevel "125.0 dB(L)".
|
||||
units = printed if ("dB(L)" in printed or "psi(L)" in printed) else (ref.event_units or "")
|
||||
key = (f"{tag} dB(L)" if "dB(L)" in units else
|
||||
f"{tag} psi(L)" if "psi(L)" in units else None)
|
||||
value = sfm.values.get(key) if key else None
|
||||
else:
|
||||
value = sfm.values.get(tag)
|
||||
@@ -166,9 +264,11 @@ def _compare_scalar(tag: str, printed: str, sfm: SfmSide, ref: XmlReport) -> Fie
|
||||
return FieldResult(tag, "match" if ok else "mismatch", printed, _render(value, printed))
|
||||
|
||||
|
||||
def _cell_diff(value: float, printed: str) -> Optional[float]:
|
||||
def _cell_diff(value: object, printed: str) -> Optional[float]:
|
||||
"""|value - printed| when the cell disagrees, else None; inf for a cell that
|
||||
is not a number."""
|
||||
is not a number. A word on SFM's side (">100", "N/A") must be printed."""
|
||||
if isinstance(value, str):
|
||||
return None if _same_text(value, printed) else float("inf")
|
||||
p = _printed_number(printed)
|
||||
if p is None:
|
||||
return float("inf")
|
||||
@@ -237,14 +337,19 @@ def series_pairs(sfm: SfmSide, ref: XmlReport,
|
||||
if field.startswith("intervals."):
|
||||
title = field[len("intervals."):]
|
||||
columns = ref.interval_columns or []
|
||||
convert = _interval_converter(title, sfm)
|
||||
counts = sfm.counts.get(title.partition(" ")[0], [])
|
||||
if convert is None or not counts or title not in columns:
|
||||
if title not in columns:
|
||||
return None
|
||||
i = columns.index(title)
|
||||
cells = [row[i] if i < len(row) else "" for _, row in (ref.intervals or [])]
|
||||
pairs = [(j, cell, convert(c)) for j, (cell, c) in enumerate(zip(cells, counts))]
|
||||
return pairs, abs(len(cells) - len(counts))
|
||||
values = sfm.interval_values.get(title)
|
||||
if values is None:
|
||||
convert = _interval_converter(title, sfm)
|
||||
counts = sfm.counts.get(title.partition(" ")[0], [])
|
||||
if convert is None or not counts:
|
||||
return None
|
||||
values = [convert(c) for c in counts]
|
||||
pairs = [(j, cell, v) for j, (cell, v) in enumerate(zip(cells, values))]
|
||||
return pairs, abs(len(cells) - len(values))
|
||||
return None
|
||||
|
||||
|
||||
@@ -254,7 +359,9 @@ def _compare_series(field: str, n_bw: int, sfm: SfmSide, ref: XmlReport) -> Fiel
|
||||
return FieldResult(field, "sfm_blank", f"{n_bw} rows", None)
|
||||
pairs, row_len = got
|
||||
diffs = [(j, d) for j, cell, v in pairs if (d := _cell_diff(v, cell)) is not None]
|
||||
n_sfm = len(sfm.counts.get(field.split(".", 1)[1].partition(" ")[0], []))
|
||||
title = field.split(".", 1)[1]
|
||||
n_sfm = (len(sfm.interval_values[title]) if title in sfm.interval_values
|
||||
else len(sfm.counts.get(title.partition(" ")[0], [])))
|
||||
return _series_result(field, n_bw, n_sfm, diffs, row_len)
|
||||
|
||||
|
||||
@@ -265,12 +372,21 @@ def _compare_samples(sfm: SfmSide, ref: XmlReport) -> list[FieldResult]:
|
||||
|
||||
|
||||
def _compare_intervals(sfm: SfmSide, ref: XmlReport) -> list[FieldResult]:
|
||||
"""One result per column, plus the interval times, which SFM does not keep."""
|
||||
"""One result per column, plus the interval times."""
|
||||
n = len(ref.intervals or [])
|
||||
return ([FieldResult("intervals.Time", "sfm_blank", f"{n} rows", None)]
|
||||
return ([_compare_interval_times(sfm, ref, n)]
|
||||
+ [_compare_series(f"intervals.{t}", n, sfm, ref) for t in ref.interval_columns or []])
|
||||
|
||||
|
||||
def _compare_interval_times(sfm: SfmSide, ref: XmlReport, n: int) -> FieldResult:
|
||||
if sfm.interval_times is None:
|
||||
return FieldResult("intervals.Time", "sfm_blank", f"{n} rows", None)
|
||||
diffs = [(j, float("inf")) for j, ((t, _), s) in enumerate(zip(ref.intervals or [], sfm.interval_times))
|
||||
if not _same_text(s, t)]
|
||||
return _series_result("intervals.Time", n, len(sfm.interval_times), diffs,
|
||||
abs(n - len(sfm.interval_times)))
|
||||
|
||||
|
||||
def compare(sfm: SfmSide, ref: XmlReport, carveouts: Sequence["Carveout"] = ()) -> list[FieldResult]:
|
||||
"""Every field Blastware's report carries, set against what SFM produced.
|
||||
A mismatch a carve-out covers and applies to becomes `accepted`."""
|
||||
|
||||
@@ -68,6 +68,21 @@ def _saturation(sfm: SfmSide, ref: XmlReport, res: FieldResult) -> bool:
|
||||
got = series_pairs(sfm, ref, res.field)
|
||||
if got is None or got[1]:
|
||||
return False
|
||||
if res.field == "intervals.Geo PVS in/s":
|
||||
# Per interval, as PeakVectorSum: an OORANGE vector sum, SFM's sum within
|
||||
# three channels at the ceiling, and a channel Blastware itself clamped in
|
||||
# that interval. 17 / 17 DL2 cells, SFM 10.01 .. 17.33 (2026-11-03).
|
||||
cols = ref.interval_columns or []
|
||||
peaks = [cols.index(c) for c in ("Tran Peak in/s", "Vert Peak in/s", "Long Peak in/s")
|
||||
if c in cols]
|
||||
rows = ref.intervals or []
|
||||
differing = [(j, cell, v) for j, cell, v in got[0]
|
||||
if isinstance(v, str) or not matches_printed(v, cell)]
|
||||
return bool(differing) and all(
|
||||
cell.strip() == "OORANGE" and not isinstance(v, str)
|
||||
and r - _TOL <= v <= 3 ** 0.5 * r * 1.01
|
||||
and any(_clamped(rows[j][1][p], r) for p in peaks if p < len(rows[j][1]))
|
||||
for j, cell, v in differing)
|
||||
differing = [(cell, v) for _, cell, v in got[0] if not matches_printed(v, cell)]
|
||||
return bool(differing) and all(
|
||||
_clamped(cell, r) and _at_ceiling(v, r)
|
||||
@@ -79,10 +94,13 @@ SATURATION = Carveout(
|
||||
id="saturation",
|
||||
fields=("TranPPV", "VertPPV", "LongPPV", "PeakVectorSum",
|
||||
"samples.Tran", "samples.Vert", "samples.Long",
|
||||
"intervals.Tran Peak in/s", "intervals.Vert Peak in/s", "intervals.Long Peak in/s"),
|
||||
"intervals.Tran Peak in/s", "intervals.Vert Peak in/s", "intervals.Long Peak in/s",
|
||||
"intervals.Geo PVS in/s"),
|
||||
evidence=("Blastware clamps a clipped channel to the range maximum and prints OORANGE; "
|
||||
"the file holds counts past full scale (32016 counts = 10.005 in/s observed). "
|
||||
"scratch/verify_against_ascii.py, 2026-08-28."),
|
||||
"scratch/verify_against_ascii.py, 2026-08-28. An interval's vector sum prints "
|
||||
"OORANGE when it exceeds the range in an interval with a clamped channel: 17 / 17 "
|
||||
"DL2 cells, 2026-11-03."),
|
||||
applies=_saturation,
|
||||
)
|
||||
|
||||
@@ -106,4 +124,29 @@ INTERVAL_COUNT_IS_DURATION = Carveout(
|
||||
applies=_interval_count_is_duration,
|
||||
)
|
||||
|
||||
CARVEOUTS: tuple[Carveout, ...] = (SATURATION, INTERVAL_COUNT_IS_DURATION)
|
||||
_MIC_UNITS = ("in/s and dB(L)", "in/s and psi(L)")
|
||||
|
||||
|
||||
def _units_is_a_display_preference(sfm: SfmSide, ref: XmlReport, res: FieldResult) -> bool:
|
||||
"""Both sides say the event has a mic; they differ only in dB against psi."""
|
||||
return (" ".join((res.bw or "").split()) in _MIC_UNITS
|
||||
and sfm.values.get("Units") in _MIC_UNITS)
|
||||
|
||||
|
||||
UNITS_IS_A_DISPLAY_PREFERENCE = Carveout(
|
||||
id="units-is-a-display-preference",
|
||||
fields=("Units",),
|
||||
evidence=("dB(L) or psi(L) is Blastware's display preference on the PC when it wrote the "
|
||||
"report, not the unit's: in report-write order (the _XML.XML mtimes) DL2's 70,034 "
|
||||
"reports switch fleet-wide in 61 clean runs, every unit at once, and no byte or "
|
||||
"bit of the event file separates the two (k-240 .. k+520, nor the 1.2 KB before "
|
||||
"the footer). Instantel documents both settings: the unit's own Microphone "
|
||||
"Units (MiniMate Plus manual 716U0101 Rev 15 §3.9.7: psi(L), dB(L) or Pa(L), "
|
||||
"keypad Right Arrow + Setups) and Blastware's report preference (Blastware "
|
||||
"manual 714U0301 Rev 22 §4, Preferences > Units and Channel: Show Mic in dB / "
|
||||
"in Linear Units). 2026-11-03."),
|
||||
applies=_units_is_a_display_preference,
|
||||
)
|
||||
|
||||
CARVEOUTS: tuple[Carveout, ...] = (SATURATION, INTERVAL_COUNT_IS_DURATION,
|
||||
UNITS_IS_A_DISPLAY_PREFERENCE)
|
||||
+195
-27
@@ -19,18 +19,19 @@ import datetime
|
||||
import hashlib
|
||||
import json
|
||||
import logging
|
||||
import math
|
||||
import os
|
||||
import re
|
||||
import struct
|
||||
from pathlib import Path
|
||||
from typing import Optional, Union
|
||||
|
||||
from .models import Event, PeakValues, ProjectInfo, Timestamp
|
||||
from .models import DeviceInfo, Event, PeakValues, ProjectInfo, Timestamp
|
||||
from . import blastware_file as _bw # avoid circular reference at module load
|
||||
from .bw_ascii_report import BwAsciiReport
|
||||
from . import waveform_codec as _wc
|
||||
from .waveform_codec import decode_waveform_v2, decoded_to_adc_counts
|
||||
from .histogram_codec import decode_histogram_body, interval_pvs
|
||||
from .histogram_codec import channels_from_records, decode_histogram_body, decode_histogram_body_full
|
||||
|
||||
# Reference pressure for dB(L) → psi conversion (20 µPa expressed in psi).
|
||||
# Same constant as sfm/sfm_webapp.html so server-side and browser-side
|
||||
@@ -862,6 +863,7 @@ _RECTIME_OFFSET_BEFORE_MARKER = 30
|
||||
# 2026-10-29). Offsets are from the first byte of the name.
|
||||
_SETUP_NAME_RE = re.compile(rb"\x1c\x08([\x20-\x7e]{1,40})\x00")
|
||||
_SAMPLE_RATE_BEFORE_NAME = 42 # uint16 BE, samples per second
|
||||
_INTERVAL_BEFORE_NAME = 40 # uint16 BE, histogram interval in seconds (2 / 5 / 15 / 60 / 300)
|
||||
_PRETRIG_BEFORE_NAME = 36 # float32 BE, seconds, negative (-0.25, -0.0625 ...)
|
||||
_RECTIME_BEFORE_NAME = 30 # float32 BE, seconds (the marker's offset above)
|
||||
_SAMPLE_RATES = (1024, 2048, 4096)
|
||||
@@ -895,17 +897,22 @@ def _ts8(b: bytes) -> Optional[datetime.datetime]:
|
||||
def _embedded_event_record(
|
||||
raw: bytes, end: int, start: Optional[datetime.datetime],
|
||||
stop: Optional[datetime.datetime], record_time: Optional[float],
|
||||
) -> tuple[Optional[datetime.datetime], str]:
|
||||
"""The trigger time from the instrument's embedded event record, or (None, why).
|
||||
) -> tuple[Optional[datetime.datetime], str, Optional[int]]:
|
||||
"""The trigger time and trigger source from the instrument's embedded event
|
||||
record, or (None, why, None).
|
||||
|
||||
Every `fe 80` before `end` (the footer) is a candidate. One counts only if
|
||||
its lead bytes match, both its times are well formed, the footer's session
|
||||
start <= trigger <= its stop, its stop is the footer's stop or a second
|
||||
before it, and its length agrees with the record time. Exactly one may
|
||||
pass: none, or more than one, is reported rather than guessed between.
|
||||
|
||||
The two bytes between the lead and `fe 80` are the trigger source, a uint16
|
||||
BE bitmask: 0x01 Tran, 0x02 Vert, 0x04 Long, 0x08 MicL, 0x200 Manual --
|
||||
Blastware's Trigger on 6,493 / 6,493 DL2 waveforms (2026-11-03).
|
||||
"""
|
||||
if start is None or stop is None:
|
||||
return None, "the footer has no start and stop to check one against"
|
||||
return None, "the footer has no start and stop to check one against", None
|
||||
found, rejected = [], 0
|
||||
i = raw.find(_EVENT_RECORD_MARKER, 6)
|
||||
while 0 <= i and i + 18 <= end:
|
||||
@@ -921,15 +928,62 @@ def _embedded_event_record(
|
||||
<= _EVENT_RECORD_SLACK_S[1])
|
||||
)
|
||||
if valid:
|
||||
found.append(trig)
|
||||
found.append((trig, int.from_bytes(raw[i - 2:i], "big")))
|
||||
else:
|
||||
rejected += 1
|
||||
i = raw.find(_EVENT_RECORD_MARKER, i + 1)
|
||||
if len(found) == 1:
|
||||
return found[0], ""
|
||||
return found[0][0], "", found[0][1]
|
||||
if found:
|
||||
return None, f"{len(found)} candidates validate"
|
||||
return None, (f"{rejected} candidate(s), none valid" if rejected else "no candidate")
|
||||
return None, f"{len(found)} candidates validate", None
|
||||
return None, (f"{rejected} candidate(s), none valid" if rejected else "no candidate"), None
|
||||
|
||||
|
||||
# A histogram's event record: the same lead, the source 0x0400, marker fe f5,
|
||||
# then its start and stop -- Blastware's Histogram Start / Stop on 63,490 /
|
||||
# 63,490 DL2 histograms. On all 63,500 its start is 0 or 1 s after the footer's
|
||||
# start and its stop 0 or 1 s before the footer's stop (2026-11-03).
|
||||
_HISTOGRAM_RECORD_MARKER = b"\xfe\xf5"
|
||||
_HISTOGRAM_RECORD_SOURCE = b"\x04\x00"
|
||||
|
||||
|
||||
def interval_times(start: datetime.datetime, interval_sec: int,
|
||||
stop: Optional[datetime.datetime], n: int) -> list[datetime.datetime]:
|
||||
"""Each histogram interval's time as Blastware prints it: the interval's
|
||||
end, start + (i + 1) x interval, capped at the stop. 2,308,524 / 2,308,524
|
||||
DL2 rows; and an event's peak date and time are its interval's (2026-11-03)."""
|
||||
out = []
|
||||
for i in range(n):
|
||||
t = start + datetime.timedelta(seconds=interval_sec * (i + 1))
|
||||
out.append(min(t, stop) if stop is not None else t)
|
||||
return out
|
||||
|
||||
|
||||
def _histogram_event_record(
|
||||
raw: bytes, end: int, start: Optional[datetime.datetime],
|
||||
stop: Optional[datetime.datetime],
|
||||
) -> tuple[Optional[datetime.datetime], Optional[datetime.datetime], str]:
|
||||
"""(start, stop) from a histogram's own event record, or (None, None, why).
|
||||
Exactly one record may validate against the footer's start and stop."""
|
||||
if start is None or stop is None:
|
||||
return None, None, "the footer has no start and stop to check one against"
|
||||
found, rejected = [], 0
|
||||
i = raw.find(_HISTOGRAM_RECORD_MARKER, 6)
|
||||
while 0 <= i and i + 18 <= end:
|
||||
a, b = _ts8(raw[i + 2:i + 10]), _ts8(raw[i + 10:i + 18])
|
||||
if (raw[i - 6:i - 2] == _EVENT_RECORD_LEAD and raw[i - 2:i] == _HISTOGRAM_RECORD_SOURCE
|
||||
and a is not None and b is not None and a <= b
|
||||
and 0 <= (a - start).total_seconds() <= 1
|
||||
and 0 <= (stop - b).total_seconds() <= 1):
|
||||
found.append((a, b))
|
||||
elif raw[i - 6:i - 2] == _EVENT_RECORD_LEAD:
|
||||
rejected += 1
|
||||
i = raw.find(_HISTOGRAM_RECORD_MARKER, i + 1)
|
||||
if len(found) == 1:
|
||||
return found[0][0], found[0][1], ""
|
||||
if found:
|
||||
return None, None, f"{len(found)} candidates validate"
|
||||
return None, None, (f"{rejected} candidate(s), none valid" if rejected else "no candidate")
|
||||
|
||||
|
||||
def _parse_record_time_seconds(raw: bytes) -> Optional[float]:
|
||||
@@ -1047,6 +1101,83 @@ def _setup_geo_range(raw: bytes) -> tuple[Optional[int], Optional[str]]:
|
||||
return None, f"geophone range not read: channel range bytes {found}"
|
||||
|
||||
|
||||
# The identity block before the setup: what the live read gets from SUB FE
|
||||
# (DeviceInfo). Offsets back from k, the setup name; matched against every DL2
|
||||
# report 2026-11-03 -- serial, version and calibration 69,983 / 69,983, the
|
||||
# battery 69,729 plus 254 that Blastware rounds half up (6.25 -> "6.3 Volts").
|
||||
_SERIAL_BEFORE_NAME = 202 # ASCII, NUL-terminated
|
||||
_BATTERY_BEFORE_NAME = 190 # uint16 BE, hundredths of a volt
|
||||
_FIRMWARE_MINOR_BEFORE_NAME = 193 # 0x11 = 17 for S338.17, as SUB EA
|
||||
_FIRMWARE_BEFORE_NAME = 147 # "S338.17"
|
||||
_DSP_BEFORE_NAME = 138 # "10.72"
|
||||
_CALIBRATION_BEFORE_NAME = 132 # dd mm yyyy (BE)
|
||||
_CALIBRATED_BY_BEFORE_NAME = 128 # "Instantel"
|
||||
_MANUFACTURER_BEFORE_NAME = 94 # "Instantel"
|
||||
_MODEL_BEFORE_NAME = 72 # "MiniMate Plus" / "BlastMate III"
|
||||
|
||||
|
||||
def _cstr(raw: bytes, i: int, limit: int = 40) -> Optional[str]:
|
||||
if i < 0:
|
||||
return None
|
||||
j = raw.find(b"\x00", i, i + limit)
|
||||
s = raw[i:j if j >= 0 else i + limit].decode("ascii", errors="replace").strip()
|
||||
return s or None
|
||||
|
||||
|
||||
def _setup_identity(raw: bytes, k: int) -> tuple[Optional[DeviceInfo], Optional[float]]:
|
||||
"""(the unit's identity, the battery in volts) from the block before the
|
||||
setup name at k."""
|
||||
if k < _SERIAL_BEFORE_NAME:
|
||||
return None, None
|
||||
serial = _cstr(raw, k - _SERIAL_BEFORE_NAME, 16)
|
||||
if not serial:
|
||||
return None, None
|
||||
c = k - _CALIBRATION_BEFORE_NAME
|
||||
try:
|
||||
cal = datetime.date(int.from_bytes(raw[c + 2:c + 4], "big"), raw[c + 1], raw[c])
|
||||
except ValueError:
|
||||
cal = None
|
||||
info = DeviceInfo(
|
||||
serial=serial,
|
||||
firmware_minor=raw[k - _FIRMWARE_MINOR_BEFORE_NAME],
|
||||
firmware_version=_cstr(raw, k - _FIRMWARE_BEFORE_NAME, 9),
|
||||
dsp_version=_cstr(raw, k - _DSP_BEFORE_NAME, 6),
|
||||
manufacturer=_cstr(raw, k - _MANUFACTURER_BEFORE_NAME),
|
||||
model=_cstr(raw, k - _MODEL_BEFORE_NAME),
|
||||
calibration_date=cal,
|
||||
calibrated_by=_cstr(raw, k - _CALIBRATED_BY_BEFORE_NAME, 32),
|
||||
)
|
||||
b = k - _BATTERY_BEFORE_NAME
|
||||
return info, int.from_bytes(raw[b:b + 2], "big") / 100
|
||||
|
||||
|
||||
# Trigger settings, in Series IV's 0x1A layout again: the trigger-source bitmask
|
||||
# at k - 19 ([29]: 0x07 geophones, 0x08 mic), the stop mode at k - 31 ([17],
|
||||
# 0 = Fixed), and each channel block's trigger level, a float32 at label + 30 --
|
||||
# in/s for a geophone, psi for the mic. The mic block's type code at label + 4
|
||||
# is Series IV's (2 = linear). Against every DL2 waveform (2026-11-03): the geo
|
||||
# level 6,447 / 6,447, the mic level 4,403 / 4,403, and Blastware prints a level
|
||||
# exactly when its channel is a trigger source and the event was not Manual.
|
||||
_TRIGGER_SOURCES_BEFORE_NAME = 19
|
||||
_STOP_MODE_BEFORE_NAME = 31
|
||||
_TRIGGER_LEVEL_AFTER_LABEL = 30
|
||||
_MIC_TYPE_AFTER_LABEL = 4
|
||||
|
||||
|
||||
def _setup_trigger(raw: bytes, k: int) -> dict:
|
||||
out = {"trigger_sources": raw[k - _TRIGGER_SOURCES_BEFORE_NAME],
|
||||
"record_stop_mode": raw[k - _STOP_MODE_BEFORE_NAME]}
|
||||
t = raw.find(b"\x00\x00\x01Tran", k, k + _CHANNEL_BLOCK_SPAN)
|
||||
if t >= 0:
|
||||
p = t + 3 + _TRIGGER_LEVEL_AFTER_LABEL
|
||||
out["trigger_level_geo"] = struct.unpack_from(">f", raw, p)[0]
|
||||
m = raw.find(b"MicL", k, k + _CHANNEL_BLOCK_SPAN)
|
||||
if m >= 0:
|
||||
out["trigger_level_mic_psi"] = struct.unpack_from(">f", raw, m + _TRIGGER_LEVEL_AFTER_LABEL)[0]
|
||||
out["mic_type"] = int.from_bytes(raw[m + _MIC_TYPE_AFTER_LABEL:m + _MIC_TYPE_AFTER_LABEL + 4], "big")
|
||||
return out
|
||||
|
||||
|
||||
def read_blastware_file(path: Union[str, Path], *, name: Optional[str] = None) -> Event:
|
||||
"""Parse a Blastware event file into an Event: `decode_blastware_bytes` on its
|
||||
bytes, `name` defaulting to the file's own (see there -- never a time source)."""
|
||||
@@ -1195,8 +1326,10 @@ def decode_blastware_bytes(raw: bytes, *, name: Optional[str] = None) -> Event:
|
||||
problems = []
|
||||
if record_type is None:
|
||||
problems.append(f"unknown record type byte 0x{type_byte:02x} at STRT[18]")
|
||||
hist_records = None
|
||||
if record_type == "Histogram":
|
||||
decoded = decode_histogram_body(body)
|
||||
hist_records = decode_histogram_body_full(body)
|
||||
decoded = channels_from_records(hist_records)
|
||||
is_waveform_body = False
|
||||
elif record_type == "Waveform":
|
||||
decoded = decode_waveform_v2(body)
|
||||
@@ -1205,7 +1338,8 @@ def decode_blastware_bytes(raw: bytes, *, name: Optional[str] = None) -> Event:
|
||||
decoded = decode_waveform_v2(body)
|
||||
is_waveform_body = decoded is not None
|
||||
if decoded is None:
|
||||
decoded = decode_histogram_body(body)
|
||||
hist_records = decode_histogram_body_full(body)
|
||||
decoded = channels_from_records(hist_records)
|
||||
if decoded is None:
|
||||
log.warning(
|
||||
"%s: body codec failed to decode (body starts %s) — "
|
||||
@@ -1236,6 +1370,11 @@ def decode_blastware_bytes(raw: bytes, *, name: Optional[str] = None) -> Event:
|
||||
ev.geo_range, range_problem = _setup_geo_range(raw)
|
||||
if range_problem:
|
||||
ev.decode_problems.append(range_problem + "; peaks assume the Normal range")
|
||||
k = _setup_name_at(raw)
|
||||
if k is not None:
|
||||
ev.device_info, ev.battery_volts = _setup_identity(raw, k)
|
||||
for attr, value in _setup_trigger(raw, k).items():
|
||||
setattr(ev, attr, value)
|
||||
if is_waveform_body:
|
||||
ev.rectime_seconds = _setup_record_time(raw)
|
||||
ev.total_samples = len(samples["Tran"]) or None
|
||||
@@ -1266,17 +1405,19 @@ def decode_blastware_bytes(raw: bytes, *, name: Optional[str] = None) -> Event:
|
||||
# embedded in the 5A stream (_embedded_event_record), so a waveform takes
|
||||
# it from there. Without a validated one the estimate stands, reported as a
|
||||
# decode problem -- never a filename's time, which is only a cross-check.
|
||||
# Histograms stay on ts1 although it runs a second early on 97% (their
|
||||
# record, marker fe f5, holds the exact start): in Blastware's timing a
|
||||
# waveform and its histogram share a second 209 times in prod's store, and
|
||||
# events is unique on (serial, timestamp) -- #51.
|
||||
# A histogram's footer start runs a second early on 97%. Its own event
|
||||
# record (marker fe f5) holds Blastware's exact start and stop, so it takes
|
||||
# them from there (#51); events are keyed unit + time + type, so a waveform
|
||||
# and its histogram may share a second.
|
||||
# ⚠ RETRACTED 2026-11-03: "histograms stay on ts1" -- that held only while
|
||||
# events were unique on (serial, timestamp).
|
||||
if is_waveform_body and ts2 is not None:
|
||||
_stop = datetime.datetime(ts2.year, ts2.month, ts2.day,
|
||||
ts2.hour, ts2.minute, ts2.second)
|
||||
_rt = _parse_record_time_seconds(raw)
|
||||
_start = (datetime.datetime(ts1.year, ts1.month, ts1.day, ts1.hour, ts1.minute, ts1.second)
|
||||
if ts1 is not None else None)
|
||||
_trig, _why = _embedded_event_record(raw, footer_pos, _start, _stop, _rt)
|
||||
_trig, _why, ev.triggered_by = _embedded_event_record(raw, footer_pos, _start, _stop, _rt)
|
||||
if _trig is not None:
|
||||
ev.timestamp_source = "event_record"
|
||||
else:
|
||||
@@ -1298,13 +1439,25 @@ def decode_blastware_bytes(raw: bytes, *, name: Optional[str] = None) -> Event:
|
||||
hour=_trig.hour, minute=_trig.minute, second=_trig.second,
|
||||
)
|
||||
elif ts1 is not None:
|
||||
_start, _hstop, _why = (_histogram_event_record(raw, footer_pos, ts1, ts2)
|
||||
if record_type == "Histogram" else (None, None, ""))
|
||||
if _start is not None:
|
||||
ev.timestamp_source = "event_record"
|
||||
ev.stop_time = _hstop
|
||||
else:
|
||||
_start = ts1
|
||||
ev.timestamp_source = "footer"
|
||||
if record_type == "Histogram":
|
||||
_problem = (f"no validated histogram event record ({_why}); the start is the "
|
||||
"footer's, a second early on 97% of measured files")
|
||||
ev.decode_problems.append(_problem)
|
||||
log.warning("%s: %s", label, _problem)
|
||||
ev.timestamp = Timestamp(
|
||||
raw=footer[2:10],
|
||||
flag=0x10,
|
||||
year=ts1.year, unknown_byte=0, month=ts1.month, day=ts1.day,
|
||||
hour=ts1.hour, minute=ts1.minute, second=ts1.second,
|
||||
year=_start.year, unknown_byte=0, month=_start.month, day=_start.day,
|
||||
hour=_start.hour, minute=_start.minute, second=_start.second,
|
||||
)
|
||||
ev.timestamp_source = "footer"
|
||||
|
||||
ev.project_info = _setup_notes(raw)
|
||||
ev.raw_samples = samples
|
||||
@@ -1327,14 +1480,29 @@ def decode_blastware_bytes(raw: bytes, *, name: Optional[str] = None) -> Event:
|
||||
# The geophone full scale is the file's range; Normal when it wasn't read.
|
||||
geo_fs = _GEO_FS_BY_RANGE.get(ev.geo_range, _GEO_NORMAL_FS_INS)
|
||||
ev.peak_values = _peaks_from_samples(samples, geo_fs) if has_samples else None
|
||||
if not is_waveform_body and ev.peak_values is not None:
|
||||
# A histogram stores each interval's vector sum (squared); the event's
|
||||
# is the largest. Combining the channel peaks instead read high on 86%
|
||||
# of DL2's histograms -- they can come from different moments.
|
||||
pvs = interval_pvs(body)
|
||||
if pvs:
|
||||
ev.peak_values.peak_vector_sum = (
|
||||
max(pvs) * _HIST_GEO_COUNTS_PER_UNIT * geo_fs / _GEO_INT16_FS)
|
||||
if ev.stop_time is None: # a histogram's record stop, else the footer's
|
||||
ev.stop_time = ts2
|
||||
if hist_records:
|
||||
# A histogram stores each interval's vector sum (squared), and each
|
||||
# channel's half-period: Blastware's per-interval Geo PVS (771,354 /
|
||||
# 771,354 DL2 cells) and frequency, (sample rate / 2) / half-period.
|
||||
unit_ins = _HIST_GEO_COUNTS_PER_UNIT * geo_fs / _GEO_INT16_FS
|
||||
ev.interval_pvs = [math.sqrt(r["pvs_sq"]) * unit_ins for r in hist_records]
|
||||
ev.interval_half_periods = {
|
||||
ch: [r[key] for r in hist_records if r[key] is not None]
|
||||
for ch, key in (("Tran", "t_halfp"), ("Vert", "v_halfp"),
|
||||
("Long", "l_halfp"), ("MicL", "m_halfp"))}
|
||||
if not ev.interval_half_periods["MicL"]:
|
||||
del ev.interval_half_periods["MicL"]
|
||||
k = _setup_name_at(raw)
|
||||
if k is not None and k >= _INTERVAL_BEFORE_NAME:
|
||||
ev.histogram_interval_sec = int.from_bytes(
|
||||
raw[k - _INTERVAL_BEFORE_NAME:k - _INTERVAL_BEFORE_NAME + 2], "big") or None
|
||||
if not is_waveform_body and ev.peak_values is not None and ev.interval_pvs:
|
||||
# The event's vector sum is the largest interval's. Combining the
|
||||
# channel peaks instead read high on 86% of DL2's histograms -- they
|
||||
# can come from different moments.
|
||||
ev.peak_values.peak_vector_sum = max(ev.interval_pvs)
|
||||
ev._a5_frames = None # not recoverable from BW file
|
||||
|
||||
return ev
|
||||
@@ -156,10 +156,11 @@ _BLOCK_MARKER = 10
|
||||
# 16-count-unit output (1 unit = 0.005 in/s = 16 ADC counts).
|
||||
_GEO_LSB_INS = 0.005
|
||||
|
||||
# Frequency formula: freq_Hz = _FREQ_NUMERATOR / half_period_samples.
|
||||
# Empirically determined to be 512 (= sample_rate / 2, where sample rate
|
||||
# is 1024 sps for the standard MiniMate Plus configuration).
|
||||
_FREQ_NUMERATOR = 512
|
||||
# Frequency formula: freq_Hz = (sample_rate / 2) / half_period_samples.
|
||||
# ⚠ RETRACTED 2026-11-03 (#50): "a fixed numerator of 512". 512 is sample_rate
|
||||
# / 2 at 1024 sps only; at 2048 sps it halved every frequency. Measured on DL2:
|
||||
# 527,915 / 527,915 cells at 1024 sps and 1,725 / 1,725 at 2048.
|
||||
_FREQ_NUMERATOR = 512 # sample_rate / 2 at the default 1024 sps
|
||||
|
||||
|
||||
def _is_data_block(block: bytes) -> bool:
|
||||
@@ -300,7 +301,11 @@ def decode_histogram_body(body: bytes) -> Optional[dict]:
|
||||
to get 1-count ADC values, then ``count / 32767 * 10.0`` for in/s)
|
||||
- Mic channel: use ``waveform_codec.mic_count_to_db(count)``
|
||||
"""
|
||||
records = _walk_auto(body)
|
||||
return channels_from_records(_walk_auto(body))
|
||||
|
||||
|
||||
def channels_from_records(records: Optional[List[dict]]) -> Optional[dict]:
|
||||
"""``decode_histogram_body``'s per-channel peaks, from records already walked."""
|
||||
if not records:
|
||||
return None
|
||||
return {
|
||||
@@ -338,17 +343,19 @@ def interval_pvs(body: bytes) -> Optional[List[float]]:
|
||||
return [math.sqrt(r["pvs_sq"]) for r in records] if records else None
|
||||
|
||||
|
||||
def half_period_to_hz(halfp: int) -> Optional[float]:
|
||||
"""Convert a half-period in samples to frequency in Hz.
|
||||
def half_period_to_hz(halfp: int, sample_rate: int = 1024) -> Optional[float]:
|
||||
"""Convert a half-period in samples to frequency in Hz:
|
||||
``(sample_rate / 2) / halfp``.
|
||||
|
||||
Returns ``None`` for half-period ≤ 5 — the device emits values in
|
||||
that range when the measured zero-crossing rate exceeds 100 Hz
|
||||
(the BW display reports `>100 Hz` for such cases). Callers can
|
||||
treat ``None`` as the `>100 Hz` sentinel.
|
||||
that range when the measured zero-crossing rate exceeds 100 Hz at
|
||||
1024 sps (the BW display reports `>100`, `>200` at 2048 sps). Callers
|
||||
can treat ``None`` as that sentinel. A half-period of 0 is Blastware's
|
||||
"N/A"; it also returns None.
|
||||
"""
|
||||
if halfp <= 5:
|
||||
return None
|
||||
return _FREQ_NUMERATOR / halfp
|
||||
return (sample_rate / 2) / halfp
|
||||
|
||||
|
||||
def geo_count_to_ins(count: int) -> float:
|
||||
|
||||
@@ -300,6 +300,10 @@ class DeviceInfo:
|
||||
# ── From SUB 08 (EVENT_INDEX_RESPONSE) ────────────────────────────────────
|
||||
event_count: Optional[int] = None # stored event count from F7 response 🔶
|
||||
|
||||
# ── From a Blastware event file's identity block (2026-11-03) ─────────────
|
||||
calibration_date: Optional[datetime.date] = None # e.g. 2019-02-20 ✅
|
||||
calibrated_by: Optional[str] = None # e.g. "Instantel" ✅
|
||||
|
||||
def __str__(self) -> str:
|
||||
fw = self.firmware_version or f"?.{self.firmware_minor}"
|
||||
mdl = self.model or "MiniMate Plus"
|
||||
@@ -548,6 +552,20 @@ class Event:
|
||||
# Geophone range from the recording setup, as ComplianceConfig.geo_range:
|
||||
# 0 Normal (10 in/s full scale), 1 Sensitive (1.25 in/s). None: not read.
|
||||
geo_range: Optional[int] = None
|
||||
# From a Blastware event file (2026-11-03); None when not read.
|
||||
device_info: Optional["DeviceInfo"] = None # the unit, as SUB FE reports it
|
||||
battery_volts: Optional[float] = None # at the event
|
||||
triggered_by: Optional[int] = None # 0x01 Tran 0x02 Vert 0x04 Long 0x08 MicL 0x200 Manual
|
||||
trigger_sources: Optional[int] = None # setup bitmask: 0x07 geophones, 0x08 mic
|
||||
trigger_level_geo: Optional[float] = None # in/s, as ComplianceConfig.trigger_level_geo
|
||||
trigger_level_mic_psi: Optional[float] = None
|
||||
record_stop_mode: Optional[int] = None # 0 = Fixed
|
||||
mic_type: Optional[int] = None # 2 = Linear Weighting (as Series IV)
|
||||
stop_time: Optional[datetime.datetime] = None # the footer's stop
|
||||
# A histogram's per-interval detail (2026-11-03); None for a waveform.
|
||||
histogram_interval_sec: Optional[int] = None # as ComplianceConfig.histogram_interval_sec
|
||||
interval_half_periods: Optional[dict] = None # channel -> half-period per interval, samples
|
||||
interval_pvs: Optional[list] = None # each interval's vector sum, in/s
|
||||
|
||||
# Sensor self-check traces keyed by channel label — the short diagnostic
|
||||
# waveforms the unit records when it pulses each sensor before monitoring
|
||||
|
||||
Reference in new issue
Block a user