From the 2026-11-04 bench:
- A MiniMate settings preview warns that a change is lost if someone is in
the unit's setup menu: a write sent with the menu open was acknowledged
and read back, then lost on Cancel or Save -- the menu writes its own
copy of the whole block back (measured both ways on BE9441).
- The two bytes after the MiniMate settings block went out as 00 00 and
the unit took them; the preview note says so instead of 'unmeasured'.
- A Micromate call-home plan no longer warns about 0x00 / 0x01: UM20147
took both, each way, on 11-03 and 11-04, matching its menu.
- read_waveform_data_raw drops the escaped-checksum's stray 0x10, as the
settings read does (it failed closed: the write's block check refused
203 bytes).
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
From the whole-branch review of phase 5:
- The preview's revision now covers the changes asked for, so a live
change must be exactly what was previewed (any API caller, not only the
page). It covers what the preview showed -- the settings block (and a
Micromate's setup name) -- not the blocks a write only echoes, which are
re-read at send and sent as read (a MiniMate's trigger block byte 5
differs by session, #46).
- The units' limits hold on the block that would result: a range, rate or
mode change alone can no longer leave a held trigger, alarm or record
time over them.
- Every MiniMate block read is logical, so push_config_raw no longer
unescapes again (a job number of 4098, 10 02, was refused at Send); the
preview runs the write's own block check, so a block it would refuse is
shown as blocked.
- A MiniMate's monitoring refusal says a stop makes it call in (spec).
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
Series3Adapter.settings reads the 1A block assembled into its 2,090
logical bytes and decodes it with micromate.setup_fields (a monitoring
unit's device-info answer is refused with 'stop monitoring first').
change_settings runs the shared change core: read the four settings
blocks, patch the settings block's fields, send Blastware's sequence
through push_config_raw with the event index, trigger and waveform blocks
as read, re-read. Refused before sending: monitoring, a value the unit
does not allow, a stale preview. push_config_raw's pre-check now raises
ImageRefused, so a refused image is audited as nothing sent.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44