- #6 Config tab by serial: the empty legacy edit form stays hidden (settings
are read-only until phase 5); the settings box shows from the start, 'Not read
yet', and a different unit's settings are never left on screen.
- #10 A start/stop that went out but was not confirmed is no longer called
'failed'. The route now adds 'sent' (acknowledged / unknown) and 'audit_id'
to a ChangeUnconfirmed -- same status, same message -- and the page says
'Start monitoring not confirmed: <what happened, audit record>'.
- #12 Device tab by serial: the empty legacy Compliance/Project tables are
hidden behind a pointer to the Config tab; a Micromate's Firmware card reads
'Thor line (version not read)' (its version string is in 0x01, undecoded).
- #16 A 504 with nothing sent adds: the connection opened, so the modem is
reachable -- another program (THOR or Blastware) may be holding the line, or
the unit is busy. Measured 2026-10-29: THOR polling leaves SFM a 0-byte 504.
New logic lives in sfm/static/device_routing.js (firmwareLabel,
deviceErrorText, changeErrorText, serialPanes) under Node tests; the page glue
in sfm_webapp.js only applies them. Checked in jsdom against the real page
(served at a fake origin, /static from disk): all four, legacy mode unchanged,
no script errors.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
GET /device/monitor/status?serial=UM...&run_state=true adds
detail.run_state = {code, name}. For the ring-path bench test: the code
during and after a call-home (0x01 for ~18 s after a stop, inferred to be
call-home attempts; 0x03 = calling home) is what the test watches. Opt-in
because it is one more round trip (~0.65 s on cellular); a plain status read
is unchanged. Series 3 has no 0x49 and ignores it.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
Final fix wave for phase 3 (start/stop monitoring), per the whole-phase review.
- I1 + M2: every failure after the send has started is a ChangeUnconfirmed
(audit_id, sent = "acknowledged" | "unknown", the cause's HTTP status) whose
message says the frame was sent and names the audit record -- the ring in
place of the ack, the four lost-ack follow-ups, and the three read-back
paths. Series4Session releases the line on it. Every audit finish goes
through one helper; a finish that fails is AuditIncomplete (500) and still
says what happened to the unit. The line is kept.
- I2: device_commands gains `sent` (1 acknowledged, 0 nothing sent, NULL
unknown) and `states` (before / seen / after), with an idempotent ADD COLUMN
in _migrate for a table created earlier on this branch.
- M1: a RADIO RING already buffered is caught before 0x96/0x97 goes out
(pre_send = read_unsolicited, one 10 ms transport read). That is a
CallHomeInProgress with sent=0, not ChangeUnconfirmed.
- M3: Series 3 reads the raw 0x1C flag (new MonitorStatus.state_flag); a byte
other than 0x00/0x10, or a short section, is unknown(...) and refused.
- M8: even_if_already on a unit already in the state notes that the read-back
proves nothing.
- M10: a scan pins `.protocol.execute(` to sfm/device_access/s4.py; both
scans fail closed on a file that does not parse.
- M11: docs corrected (CLAUDE.md phase-2 sentence, phase-3 bullet, REST list;
micromate/protocol.py scope and the 0x49 read_state docstring; s4.py; route
docstrings). "No command has ever been originated" is NOT retracted.
- M12: GET /db/device_commands normalises the serial.
- Minors: unused imports, S3 dry-run frames and 120 s timeout pinned, test
rename, serial-cache and short-0x49 tests, _RUN_STATES comment.
Schema: two NULLable columns on the branch-new device_commands table, added
by _migrate on open; no backfill. No codec change, TOOL_VERSION unchanged.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
THOR's watcher (and Blastware's ACH) store every event through
/db/import/idf_file and /db/import/blastware_file, with the paired report.
Storing a download of the same event afterwards overwrote that richer copy:
on Series 4 the file, .h5 and sidecar were rewritten (extensions dropped);
on Series 3 the row lost PVS, project strings and ZC frequencies and was
repointed at a second, review-less file set.
persist_download now looks up (serial, timestamp) first. A row there is
returned as it stands -- inserted false, detail.already_stored true -- with
no store call, no insert_events and no sidecar write. Never merge.
- DownloadedEvent gains `timestamp` (the unit's own event time) and
`record` (Series 4's 0x0C fields); both adapters set them.
- The Series-3 `event is None` guard now runs before backfill/save, with a
message that is true there ("nothing was stored").
- Tests build the watcher's state exactly as the import endpoints do and
prove the row dict, the sidecar bytes and the file mtimes are unchanged.
No schema change, no migration, no codec change.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
The /device guard let every non-UM serial through before its held-line
check. FastAPI drops an undeclared `serial`, so `?serial=BE18193` on a
legacy route still ran Series-3 code at an address holding a Series-4
line -- the hole the guard exists to close. Serial-aware routes go
straight to DeviceAccess, which refuses that case itself; everything
else is checked. baud is no longer parsed (it is not in the address
key, and pydantic's coercion made "38400.0" a second way past).
Also, from the same review:
- RingWatchTransport clears its frame state on every write, so a stray
STX on an idle line cannot hide the ring that answers the next request.
- Series4Session.is_open reads _client once; held_serial() calls it
without the unit lock, and a concurrent hang-up between two reads was
an AttributeError (a 500).
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44