- s4_change_call_home's read_state now returns an unknown(0xNN) run state as
it is, so the change core refuses it (UnitStateUnknown, nothing sent), as
start/stop already does; it checked only for calling_home.
- run_change records the snapshot on the lost-ack path too: after an ack is
lost, what the unit now holds (and, on Series 4, whether [118:120] moved) is
what tells whether the write landed.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
- micromate: ENABLEABLE_WRITES gains 0x7E/0x7F (the call-home write and its
confirm; spec row 9, enable/disable only); MicromateClient.get_call_home_content()
returns the 126-byte 0x2C content.
- sfm/device_access: CallHomeState (serial, series, enabled, dial_string, detail
with byte5 and the whole block); s4_call_home_state reads bit 0 of [5] and the
dial string at [6:46]; s4_change_call_home runs the shared change core with
micromate.writes.plan_call_home_enabled -- built from the read run_change made
just before, and that same plan is the one sent. A unit calling home (run
state 0x03) is refused, nothing sent. The read-back judges the edited bit
only; the snapshot records both blocks and every changed offset -- [118:120]
is unit-maintained and always moves.
- The write-ceiling tests take 0x71 (the setup write, phase 5) as their
over-the-ceiling example now that 0x7E is enableable.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44