claude 574d40027f feat: enhance logging messages in ach_server.py and add experiments.py for protocol minimization 2026-04-16 21:14:58 +00:00
claude 0358acb51d feat: add high-water mark state tracking to ach_server + fix monitoring flag
ach_server.py:
- Add ach_state.json per-unit state tracking (keyed by serial number)
- count_events() before any download; skip session if no new events since last call-home
- Download only events beyond the previous high-water mark (all_events[last_count:])
- --max-events N safety cap for first-run units with many stored events
- state_path and max_events wired through AchSession constructor and serve()

client.py (_decode_monitor_status):
- Revert monitoring flag to section[1] == 0x10 (was incorrectly changed to section[6])
- Fix battery/memory offsets to section[-10:-8], [-8:-4], [-4:] (no trailing checksum byte)
- Both confirmed by full byte diff of all 144 0xE3 data frames in 4-8-26/2ndtry capture

Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
2026-04-16 21:14:58 +00:00
claude cf7d838bf4 feat: add SocketTransport and ach_server.py inbound ACH server
minimateplus/transport.py:
- Add SocketTransport(TcpTransport) — wraps an already-accepted inbound
  socket; connect() is a no-op; everything else inherited from TcpTransport.
  Enables the ACH server to reuse all existing protocol/client code without
  any changes.

bridges/ach_server.py:
- Minimal inbound ACH server — listens on port 12345, accepts call-home
  connections from MiniMate Plus units, runs the full BW protocol:
  startup handshake → get_device_info → get_events(full_waveform=True)
- Saves device_info.json + events.json + raw_rx_<ts>.bin + session log
  per connection to bridges/captures/ach_inbound_<ts>/
- raw_rx.bin is byte-compatible with existing Analyzer tooling
- Taps transport.read() to capture raw S3 bytes alongside parsed output
- Each connection runs in its own daemon thread
- Clearly distinguishes push vs pull protocol in the startup log

Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
2026-04-16 21:14:58 +00:00
claude 5e44cdc668 feat: add splitter mode to ach_bridge.py (--mirror HOST:PORT)
Adds a production-safe headphone-splitter mode:
- Device bytes tee'd to both --upstream (primary/prod) and --mirror (new server)
- Only primary server responses are returned to the device
- Mirror connect/write failures are non-fatal and logged; prod is unaffected
- New raw_mirror_<ts>.bin capture file alongside raw_client/raw_server

Three modes: standalone (capture only), bridge (one upstream), splitter (two).
Default listen port changed to 12345 to match project ACH setup.

Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
2026-04-16 21:14:58 +00:00
claude 37d32077a4 feat: add ACH TCP bridge, serial tap tool, and Serial Watch tab
- bridges/ach_bridge.py: transparent TCP bridge that MITMs the MiniMate Plus
  call-home connection — forwards to real ACH server while logging all frames
  to raw_client/raw_server .bin files compatible with parse_capture.py;
  standalone capture mode for lab use without a real server

- bridges/serial_watch.py: RS-232 serial monitor with live S3 frame parsing;
  taps the line between MiniMate and modem (RV50/RV55); captures raw bytes,
  .log and .jsonl; --ack-ok mode auto-replies to AT commands; fixed fatal
  indentation bug in the original that silently prevented any data capture

- seismo_lab.py: new "Serial Watch" fourth tab (SerialWatchPanel) wrapping
  serial_watch.py functionality; COM port picker with refresh, baud config,
  ack-ok toggle, colour-coded live frame log (teal frames / yellow ctrl /
  blue AT), raw .bin capture auto-fed into Analyzer tab on stop

Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
2026-04-16 21:14:58 +00:00
claude de02f9cccf Handle cold-boot timeout for TCP connections
- bridges/tcp_serial_bridge.py: increase default boot_delay 2s → 8s to
  cover MiniMate Plus cold-start time (unit wakes from RS-232 line
  assertion but takes 5-10s to be ready for POLL_PROBE).
- sfm/server.py: add _run_with_retry() — on TCP connections only, retries
  once on ProtocolError. Serial timeouts are not retried (usually a real
  fault). Confirmed behaviour: unit wakes purely from RS-232 line voltage,
  no software wake-up frame needed.
2026-03-31 12:02:52 -04:00
claude da446cb2e3 add tcp_serial_bridge.py 2026-03-31 11:52:11 -04:00
claude 0db3780e65 feat: raw bin files now recieve timestamped filenames. 2026-03-11 03:09:34 -04:00
claude 22d4023ea0 chore: update version to v0.5.1 in s3_bridge.py
docs: update Instantel protocol reference with framing corrections and clarifications
2026-03-03 16:30:09 -05:00
claude 8ca40d52a4 feat: gui now has "add mark" feature for marking log 2026-03-02 20:25:57 -05:00
claude 9db55ffcee feat: added raw capture pipeline. added simple windows gui. 2026-03-02 19:30:02 -05:00
claude 6e6c9874f0 fix: swapped default COM ports. 2026-03-02 15:56:32 -05:00
claude 43c9c8b3a3 feat: added raw binary data tracking for accurate format parser. 2026-03-02 15:47:52 -05:00
claude 0ad1505cc5 feat: update s3_bridge to v0.4.0 with annotation markers and dual log output 2026-02-27 02:24:47 -05:00
claude e47efa3708 add: log also saved in binary. updated the reference material. 2026-02-26 18:08:37 -05:00
claude 5e1a532544 fix: fixed loop causing cpu overload, cleaned up outputs, disabled in console logging because apparently its resource heavy and i want this to run on a toaster. 2026-02-25 16:55:34 -05:00
claude 832bc93233 add: timestamped logs, clean shut down and flush with CTRL+C, print to file. 2026-02-25 16:26:13 -05:00
claude 9c0f53edc5 fix: changed time out to 0.1. fixed infinite loop 2026-02-25 15:15:57 -05:00
claude 0a02236d35 initial scaffold 2026-02-25 03:22:00 -05:00