Group A of the file-only decode, every field matched against every DL2
report (2026-11-03):
- Identity block before the setup name, what the live read gets from
SUB FE: serial k-202, firmware k-147, DSP version k-138, calibration
date k-132 + 'by' k-128, manufacturer k-94, model k-72, firmware
minor k-193. Event.device_info (DeviceInfo gains calibration_date /
calibrated_by). Serial, Version and Calibration 69,983 / 69,983.
- Battery: uint16 hundredths of a volt at k-190 (Event.battery_volts).
69,729 exact; the other 254 are Blastware rounding half up.
- Trigger source: the two bytes between the embedded event record's
lead and fe 80, a bitmask (0x01 Tran 0x02 Vert 0x04 Long 0x08 MicL
0x200 Manual): 6,493 / 6,493. Event.triggered_by.
- Trigger settings in Series IV's 0x1A layout: sources bitmask k-19,
stop mode k-31 (0 = Fixed), each channel's float32 level at
label+30 (geo in/s, mic psi), mic type code at MicL+4 (2 = Linear
Weighting). Geo level 6,447 / 6,447, mic 4,403 / 4,403; Blastware
prints a level when its channel is a trigger source and the event
was not Manual. The mic level's dB uses 6895 Pa/psi (4,272 / 4,272
against 4,271 at 6894.757).
- .h5 attrs for all of them (additive).
- Checker: SFM's side reports the ten fields; the mic trigger level
follows the report's dB/psi. Carve-out
units-is-a-display-preference: dB or psi is Blastware's PC setting
when it wrote the report -- DL2's reports switch fleet-wide in 61
clean runs by write time, and no byte of the file separates them.
Two tests that pinned BatteryLevel / Calibration as blank now pin the
match.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
Three causes behind the histograms the checker found decoding wrongly:
1. The file decoder tried the waveform codec first, whatever the record
type. It accepted BE9440 / BE9557 / BE17354's 2018 5 s histograms and
returned ~5x too many 'samples' (K440HDXX.XH0H: SFM 44,504, Blastware
6,976). The codec now follows STRT[18] (0x46 / 0x0A on 70,041 /
70,041 DL2 files); only an unknown type falls back to trial order, and a
chosen codec that fails is a decode problem rather than a silent switch.
2. The sub-minute layout check required each record's 'zero word' to be
0000. It is the high word of the interval's PVS squared, non-zero above
1.28 in/s, so a one-block histogram with a loud interval was not
recognised (T193KR5M.X90H, K440HA3C.JM0H, R352HFZ7.530H decoded to
nothing). The check is now the measured relation peak <= PVS <=
sqrt(3) * peak, which holds on 34,502,955 / 34,502,955 DL2 sub-minute
intervals. The no-terminal-tail trim uses the same test. Two test
builders wrote PVS bytes no real record has (one still in the retracted
little-endian layout); they now write peak^2 in the measured layout, and
the retraction test keeps a legacy builder of its own.
3. Checker carve-out interval-count-is-duration: Blastware's Number of
Intervals is (stop - start) / interval from the footer times, and its
own interval table lists one block fewer when the unit never wrote the
last minute. SFM matches the table (T193KSWP.FF0H: 2,880 vs 2,850).
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
- A matching event that now fails outright is a regression: compare_runs
walks the previous run's matching rows, so a check that collapses to
one error row no longer hides every field it used to match. Counts
moved are taken over the events both runs checked.
- The default baseline is the newest completed run (run.json written) of
the same scope; a 2,000-event sample is no baseline for a full run.
changes.md names the previous run's scope.
- The PVS saturation carve-out now needs Blastware's OORANGE, a channel
Blastware clamped at SFM's ceiling, and SFM's sum within three channels
at the ceiling -- an unclipped Sensitive-range channel read 8x can no
longer let an 8x sum through.
- 'Fields fully matching' needs a match: an always-empty element proves
nothing. Events without a report are a line of their own.
- CLAUDE.md: histogram PVS described correctly; 35 sub-minute histograms
plus 2 one-minute no-mic ones, not '~37 sub-minute'.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
A mismatch becomes 'accepted' only through a written carve-out whose
evidence does not rest on SFM's output. Saturation: Blastware clamps a
clipped channel to the range maximum and prints OORANGE, while the file
holds counts past full scale. SFM's value must sit at the ceiling
(r - 0.0006 .. r * 1.01), so a Sensitive-range event read 8x high on
SFM's Normal assumption stays a mismatch; a vector sum is accepted when
a clipped channel under it is at the ceiling. series_pairs() is now the
one place waveform rows and interval columns are paired.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9