Final fix wave for phase 3 (start/stop monitoring), per the whole-phase review.
- I1 + M2: every failure after the send has started is a ChangeUnconfirmed
(audit_id, sent = "acknowledged" | "unknown", the cause's HTTP status) whose
message says the frame was sent and names the audit record -- the ring in
place of the ack, the four lost-ack follow-ups, and the three read-back
paths. Series4Session releases the line on it. Every audit finish goes
through one helper; a finish that fails is AuditIncomplete (500) and still
says what happened to the unit. The line is kept.
- I2: device_commands gains `sent` (1 acknowledged, 0 nothing sent, NULL
unknown) and `states` (before / seen / after), with an idempotent ADD COLUMN
in _migrate for a table created earlier on this branch.
- M1: a RADIO RING already buffered is caught before 0x96/0x97 goes out
(pre_send = read_unsolicited, one 10 ms transport read). That is a
CallHomeInProgress with sent=0, not ChangeUnconfirmed.
- M3: Series 3 reads the raw 0x1C flag (new MonitorStatus.state_flag); a byte
other than 0x00/0x10, or a short section, is unknown(...) and refused.
- M8: even_if_already on a unit already in the state notes that the read-back
proves nothing.
- M10: a scan pins `.protocol.execute(` to sfm/device_access/s4.py; both
scans fail closed on a file that does not parse.
- M11: docs corrected (CLAUDE.md phase-2 sentence, phase-3 bullet, REST list;
micromate/protocol.py scope and the 0x49 read_state docstring; s4.py; route
docstrings). "No command has ever been originated" is NOT retracted.
- M12: GET /db/device_commands normalises the serial.
- Minors: unused imports, S3 dry-run frames and 120 s timeout pinned, test
rename, serial-cache and short-0x49 tests, _RUN_STATES comment.
Schema: two NULLable columns on the branch-new device_commands table, added
by _migrate on open; no backfill. No codec change, TOOL_VERSION unchanged.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
One lost 1F reply made the list return 1 of 3 events as a 200, and on a
download gave a false 404. The list also ran on the 120 s download
timeout, so each lost reply stalled the walk 120 s with the unit locked.
- get_events() strict mode (headers_only, or only_key): a lost 0A reply,
a lost 1F(browse) reply on the success path and on the partial-record
path all re-raise their ProtocolError; a 1F that hands back a key
already walked raises ProtocolError("event chain did not advance ...").
Legacy calls (none of the new options) behave exactly as before --
pinned by tests of the same three faults under get_events().
- Series3Adapter.list_events runs on the default timeout (10 s on TCP);
download_event keeps 120 s.
- FakeProto gains optional lost-reply injection; its default is unchanged.
The repeat-key guard sits at the loop head, which is reached only for a
non-null key -- equivalent to checking each 1F's key, in one place.
Read-only; nothing new on the wire. No codec, store or DB change.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
Series3Adapter.download_event compared the timestamp only after
download_event_by_key had run the whole 5A. A stale id cost a full
download of the wrong event (minutes on cellular), could surface the
64 KB-page 502 instead of 409, and a lost 0C reply was reported as "the
unit was erased".
- get_events() gains only_key_timestamp: with only_key, if the target's 0C
says another time (or none), the target takes the existing bypass --
no 1F(arm), no POLL, no 5A. A new branch only; it adds no command.
- download_event_by_key(key4, *, expected_timestamp=None) passes it on.
- The adapter converts the id's stamp to that ISO form and checks, in
order: no event -> 404; no readable 0C timestamp -> 502 MalformedReply
("could not read ... record (0C)"); a different time -> 409 StaleEvent;
no frames -> 502.
- The fake's download mirrors the real walk (no frames on a mismatch) and
records what it was asked for.
- Legacy get_events() (none of the new options) is pinned by a test of
its exact call sequence and 5A arguments, written before the change.
Read-only; nothing new on the wire. No codec, store or DB change.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
list_event_headers() walks every event's 0A/1E/0C/1F without starting a 5A.
download_event_by_key() downloads one event in full and walks past the others
without their 5A, stopping once it has it. Both ride two new keyword options on
get_events() (headers_only, only_key); the default path is unchanged.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
The BW filename encodes only the serial NUMBER — `<letter><3 digits>`, so
`L895…` is 10895 and nothing more. The two-letter family prefix is not in it:
"BE" is a MiniMate Plus, "BA" a BlastMate. Both are Series III and their
files are byte-identical in every way that matters — all 1,493 BlastMate
binaries in the DL2 archive decode through the existing codec at 100%, same
four channels — so the serial string was the only thing standing between SFM
and BlastMate support.
Two sites synthesised the prefix and got it wrong:
- waveform_store `_serial_from_bw_filename` returned f"BE{num}" on import, so
a BlastMate event was filed under a unit that does not exist, silently, and
Terra-View read it straight through. Split into
`_serial_number_from_bw_filename` (the number, which the filename really
does carry) and a new `_serial_from_bw_bytes` that reads the serial out of
the body and accepts it only when its numeric part agrees with the
filename. save_imported_bw now prefers hint -> body -> filename guess.
Verified against real archive bytes for BA9229, BA10060, BA10895, BA15957
and BE9558/BE11529/BE18003.
- client `_decode_0a_partial_header` searched for a literal b"BE" in the
monitor-log partial record. On a BlastMate that returns -1 and skips the
whole block, so the geo threshold went missing along with the serial. Now
matches any two-letter prefix, and requires the NUL terminator — stricter
than the bare two-byte search it replaces.
Nothing to migrate: no BlastMate events are in prod. The archive's BA units
last recorded 2018-10 (BA9229, BA15957), 2023-08 (BA10895) and 2023-11
(BA10060), and the prod backfill only reaches back to ~May 2025.
21 tests. Suite: 309 passed, same 16 pre-existing failures as at HEAD
(15 missing ASCII fixtures + one peak_values assertion, all untouched here).
Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01HgTe8CamXAHcAmaQ6QNcog
Replaces the broken legacy int16 LE decoder in client.py with the
verified multi-channel codec. Three changes:
1. blastware_file.extract_body_bytes(a5_frames) — new helper that
factors out the body-reconstruction logic from write_blastware_file
so both writers (BW binary) and decoders (sample arrays) can use
the same canonical bytes.
2. waveform_codec.decode_a5_frames(a5_frames) — production entry point.
Returns the raw_samples dict consumers expect (Tran/Vert/Long as
int16 ADC counts; MicL as native ADC counts). Internally:
A5 frames → extract_body_bytes → decode_waveform_v2
→ decoded_to_adc_counts (geos ×16; mic pass-through)
3. waveform_codec.mic_count_to_db(count) — MicL ADC → dB(L) per BW's
display formula:
dB = sign(count) × (81.94 + 20 × log10(|count|)) for |count| ≥ 1
Verified against V70 fixture: count=813 → 140.14 dB (BW PSPL 140.1).
client.py:_decode_a5_waveform is reduced to a thin wrapper that calls
decode_a5_frames and populates event.raw_samples. Original implementation
preserved as _decode_a5_waveform_LEGACY (dead code; reference only).
Also fixed a tail-end bug in decode_waveform_v2 where trailer-section
"40 02" markers (containing ASCII serial bytes, NOT real segment headers)
were being mis-interpreted, producing 2 spurious samples per channel at
the end of each event. Added bytes [12:14] == "02 00" validation to
reject non-header markers.
7 new pytest tests cover the new helpers and dB conversion. Total:
71 passing (up from 64).
Known limitation (carried over from before): the walker still stops
mid-event on the loudest fixtures (SP0/SS0/SV0/event-b) at some
mid-segment edge cases not yet characterized. Every sample reached
is decoded correctly; the walker just doesn't reach all of them.
Loud events still yield 5,000–15,000 byte-exact samples each.
### Added
- **Layered event storage architecture.** Each event now lands as four
files in the per-serial waveform store, each with a clear role:
- `<filename>` — the Blastware-readable binary (BW file). Untouched.
- `<filename>.a5.pkl` — the raw 5A frames (regenerative source).
- `<filename>.h5` — clean per-channel waveform arrays in physical
units (in/s for geo, psi for mic) plus event metadata (HDF5 with
gzip compression). This is the canonical format for downstream
analysis tools.
- `<filename>.sfm.json` — the modern review/metadata sidecar (peaks,
project, source provenance, review state, extensions).
SQLite (`seismo_relay.db`) is the searchable index over all four.
- **Plot-ready waveform JSON (`sfm.plot.v1`).** The `/device/event/{idx}/waveform`
and `/db/events/{id}/waveform.json` endpoints now return samples in
physical units with explicit time-axis metadata, peak markers, and
per-channel unit hints — no more guessing the ADC-to-velocity scale
client-side. The webapp waveform viewer was rewritten to consume
this shape.
- **In-app waveform viewer accuracy fix.** The standalone SFM webapp
viewer was scaling geophone amplitudes by `geoAdcScale / 32767`
(≈ 6.206 / 32767), where `geoAdcScale = 6.206053` is the device's
*in/s per V* hardware constant — not the ADC-counts-to-velocity
factor. This silently scaled every plot ~38% too low for Normal-range
geophones (the correct full-scale is 10.0 in/s, or 1.25 in/s for
Sensitive). Conversion is now done server-side using the geo_range
from compliance config; the client just plots.
- New `sfm/event_hdf5.py` module: `write_event_hdf5()`,
`read_event_hdf5()`, plus a plot-JSON helper.
- Backfill script extended to also emit `.h5` for existing events.
### Dependencies
- Added `h5py>=3.10` and `numpy>=1.24` for the HDF5 storage layer.
- Added `python-multipart>=0.0.7` (required by FastAPI for the
`/db/import/blastware_file` endpoint introduced in this release).
- Added `waveform_key` and `event_timestamp` columns to `CachedEvent` and `CachedWaveform` for integrity verification.
- Implemented logic to flush the cache when a mismatch in (waveform_key, event_timestamp) is detected during event and waveform updates.
- Enhanced `set_events` and `set_waveform` methods to check for mismatches and trigger cache eviction as necessary.
- Introduced a new `LiveCache` class to manage in-memory caching of live device data, separating it from the server logic for better testability.
- Added tests to verify the correctness of cache invalidation logic, particularly for post-erase key reuse scenarios.
- Updated web application to include a "Force refresh" toggle, allowing users to bypass the cache and re-fetch data from the device.
For 2-second events at 1024 sps the "Project:" metadata frame appears
beyond chunk 32 (the old default cap), causing the safety limit to be
hit and ~34 KB of waveform data to be downloaded instead of stopping
at the metadata frame. Raising max_chunks to 128 ensures
stop_after_metadata=True can locate the metadata frame for record
times up to ~4 seconds.
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
- Added `CallHomeConfig` model to represent the Auto Call Home settings.
- Introduced methods in `MiniMateClient` for reading (`get_call_home_config`) and writing (`set_call_home_config`) the call home configuration.
- Updated `MiniMateProtocol` with new commands for call home operations (SUB 0x2C for read, SUB 0x7E for write, and SUB 0x7F for confirm).
- Created API endpoints for retrieving and updating call home settings in the server.
- Enhanced the web interface with a new "Call Home" tab for user interaction with call home settings.
- Implemented JavaScript functions for reading and writing call home configurations from the web app.
Add full decode pipeline for 0x2C partial records from the device's event
list, representing continuous monitoring intervals where no threshold was
crossed. These records appear interleaved with full triggered events in the
browse walk and were previously ignored.
minimateplus/models.py
- Add MonitorLogEntry dataclass: key, start_time, stop_time, serial,
geo_threshold_ips, raw_header, duration_seconds property
minimateplus/protocol.py
- read_waveform_header() now returns (data_rsp.data, length) — full payload
including the record-type byte at position 0 — instead of the sliced header.
Callers that need the old slice use raw_data[11:11+length] as before.
minimateplus/client.py
- Add _decode_0a_partial_header(): auto-detects 9-byte (sub_code=0x10) vs
10-byte (sub_code=0x03) timestamp format, handles 1-byte inter-timestamp
gap, extracts serial via BE anchor and geo threshold via Geo: anchor.
- Add get_monitor_log_entries(skip_keys=None): browse walk (1E → 0A → 1F),
decodes partial records, skips full records and already-seen keys.
minimateplus/__init__.py
- Export MonitorLogEntry
bridges/ach_server.py
- After get_events(), call get_monitor_log_entries(skip_keys=seen_keys) and
save new entries to monitor_log.json in the session directory.
- Add _monitor_log_entry_to_dict() helper.
- Include monitor log keys in downloaded_keys for state persistence.
CLAUDE.md / CHANGELOG.md
- Document 0x2C partial record layout (timestamp format, ASCII metadata
region, 1-byte gap edge case) confirmed from 4-11-26 MITM capture.
- Version bump to v0.10.0; update What's next.
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
_decode_event_count: read uint16 BE at offset 10 (confirmed 2026-04-10 from
live BE11529 event index — data[10:12]=0x0006=6, matches device LCD).
Previous uint32 at offset 3 always returned 1 regardless of event count.
ach_server.py: use device_info.event_count (already fetched during connect())
instead of calling count_events() separately. This saves 2*N round-trips and
avoids the 1F linked-list walk which was overcounting on some devices.
count_events() kept as fallback when connect() is skipped (--events-only).
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
- Replace all Unicode arrows/checkmarks (-> [OK] [FAIL]) in ach_server.py
and client.py log calls — Windows cp1252 console can't encode them
- Fix DeviceInfo attribute: serial_number -> serial
- Fix _device_info_to_dict key: serial_number -> serial
- Demote count_events 1E/1F per-key log lines from WARNING to DEBUG
(they were flooding the console on devices with many stored events)
- FileHandler now opens with encoding='utf-8' so session log files
can hold any characters without codec errors
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
ach_server.py:
- Add ach_state.json per-unit state tracking (keyed by serial number)
- count_events() before any download; skip session if no new events since last call-home
- Download only events beyond the previous high-water mark (all_events[last_count:])
- --max-events N safety cap for first-run units with many stored events
- state_path and max_events wired through AchSession constructor and serve()
client.py (_decode_monitor_status):
- Revert monitoring flag to section[1] == 0x10 (was incorrectly changed to section[6])
- Fix battery/memory offsets to section[-10:-8], [-8:-4], [-4:] (no trailing checksum byte)
- Both confirmed by full byte diff of all 144 0xE3 data frames in 4-8-26/2ndtry capture
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
section[6] is the monitoring flag (was wrongly section[1] — section[1] is always
0x00 in both states). Battery and memory fields use relative-from-end offsets
(section[-11:-9], section[-9:-5], section[-5:-1]) instead of absolute positions,
which broke when the payload grew by 3 bytes in monitoring mode.
Confirmed from full byte diff of 142 0xE3 frames in 4-8-26/2ndtry capture.
SFM start_monitoring now polls /device/monitor/status every 5s for up to 60s
instead of a fixed 25s delay (unit runs ~40s on-device sensor check before
confirming monitoring state).
Also corrects stale 1C→6E response anomaly claim in protocol reference — no
exceptions to the 0xFF−SUB rule are known.
- Introduced new SUBs for monitoring status, start, and stop commands in protocol.py.
- Implemented read_monitor_status, start_monitoring, and stop_monitoring methods in MiniMateProtocol class.
- Added new API endpoints for monitoring status retrieval and control in server.py.
- Enhanced the web application with a monitoring panel, including battery and memory status display.
- Created a new Python script to parse SUB 0x1C response frames for monitoring status.
- Documented the monitoring status response format and field locations in markdown and text files.
Frame index 9 was assumed to be the device terminator based on the
9-frame original blast capture. For streams with >9 frames (current
device produces 35), fi==9 is live waveform data — the skip was
dropping ~133 sample-sets per event.
Terminator detection is handled upstream via page_key==0x0000 in
read_bulk_waveform_stream, so no index-based skip is needed here.
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
Two improvements to eliminate the ~2-min-per-event wait and unnecessary
full-event-list download when only one event is requested:
1. protocol.py: pass timeout=10.0 to _recv_one in the 5A chunk loop.
Device responds within ~1s per chunk; 10s gives a safe 10x buffer.
End-of-stream detection (raw_bytes=1) now fires in 10s instead of 120s,
cutting ~110s of dead wait per event.
2. client.py: add stop_after_index parameter to get_events(). When set,
iteration stops immediately after the target event is collected — no
further 0A/1E/0C/5A/1F cycles for events the caller doesn't need.
3. server.py: pass stop_after_index=index to both /device/event/{idx}
and /device/event/{idx}/waveform endpoints so a single-event request
only downloads that one event.
Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>