minimateplus.histogram_codec.half_period_to_hz (and _FREQ_NUMERATOR = 512) assumes a histogram sampled at 1,024 sps: freq = 512 / half-period. Frequency is really (sample rate / 2) / half-period. So the helper is 2x low at 2,048 sps and 4x low at 4,096 sps.
Measured (2026-10-26, BE9441)
K441LTOK.QZ0, whose export says "Sample Rate : 2048 sps": 66/66 frequencies match its export with 1024/hp. With 512/hp they're half.
K441LTON.900, "Sample Rate : 4096 sps": 3,398/3,398 intervals match with 2048/hp (decoded with the #47/#49 reader).
The archive's 13,089 histograms with exports: exact using each file's own rate / 2.
Impact today: none found (latent)
git grep on dev finds no production caller. Histogram frequencies shown by SFM, the sidecar and the PDF come from Blastware's paired report (zc_freq_hz), not from the half-periods. The helper is used by its own tests, and analysis_idf/idfh_decode.py and the micromate/idf_file.py docs also say 512/hp; those are worth checking for Thor's own rates.
Fix
Take the sample rate as a parameter, read from the file's setup or the decoded event, rather than a constant. It must be done before anything computes frequencies from half-periods, e.g. a histogram download with no paired report, which is what SFM's own MiniMate download produces.
## Summary
`minimateplus.histogram_codec.half_period_to_hz` (and `_FREQ_NUMERATOR = 512`) assumes a histogram sampled at **1,024 sps**: freq = 512 / half-period. Frequency is really **(sample rate / 2) / half-period**. So the helper is 2x low at 2,048 sps and **4x low at 4,096 sps**.
## Measured (2026-10-26, BE9441)
- `K441LTOK.QZ0`, whose export says "Sample Rate : 2048 sps": 66/66 frequencies match its export with 1024/hp. With 512/hp they're half.
- `K441LTON.900`, "Sample Rate : 4096 sps": 3,398/3,398 intervals match with 2048/hp (decoded with the #47/#49 reader).
- The archive's 13,089 histograms with exports: exact using each file's own rate / 2.
## Impact today: none found (latent)
`git grep` on `dev` finds no production caller. Histogram frequencies shown by SFM, the sidecar and the PDF come from Blastware's paired report (`zc_freq_hz`), not from the half-periods. The helper is used by its own tests, and `analysis_idf/idfh_decode.py` and the `micromate/idf_file.py` docs also say 512/hp; those are worth checking for Thor's own rates.
## Fix
Take the sample rate as a parameter, read from the file's setup or the decoded event, rather than a constant. It must be done before anything computes frequencies from half-periods, e.g. a histogram download with no paired report, which is what SFM's own MiniMate download produces.
Fixed on dev (merge 31231d7, fix 2b698e7). Ships in the next release.
half_period_to_hz(halfp, sample_rate=1024) now computes (sample_rate / 2) / halfp. The fixed 512 was correct at 1024 sps only.
Measured against Blastware's _XML.XML reports on DL2: 527,915 / 527,915 frequency cells at 1024 sps and 1,725 / 1,725 at 2048 sps.
Blastware's words, measured on ~3.1 M cells:
N/A for a half-period of 0
>100 (>200 at 2048) at 5 samples or fewer
<1.0 below 1 Hz
Decode checker: all four channels' per-interval frequencies now match every DL2 histogram, with 0 regressions.
SFM now also stores each interval's half-periods in the .h5 (/intervals/half_period/<ch>), so frequencies can be recomputed at any sample rate.
Protocol reference: Appendix D.6.9.
**Fixed on `dev`** (merge `31231d7`, fix `2b698e7`). Ships in the next release.
- `half_period_to_hz(halfp, sample_rate=1024)` now computes `(sample_rate / 2) / halfp`. The fixed 512 was correct at 1024 sps only.
- **Measured against Blastware's `_XML.XML` reports on DL2:** 527,915 / 527,915 frequency cells at 1024 sps and 1,725 / 1,725 at 2048 sps.
- **Blastware's words, measured on ~3.1 M cells:**
- `N/A` for a half-period of 0
- `>100` (`>200` at 2048) at 5 samples or fewer
- `<1.0` below 1 Hz
- **Decode checker:** all four channels' per-interval frequencies now match every DL2 histogram, with 0 regressions.
- SFM now also stores each interval's half-periods in the `.h5` (`/intervals/half_period/<ch>`), so frequencies can be recomputed at any sample rate.
Protocol reference: Appendix D.6.9.
Blocking a user prevents them from interacting with repositories, such as opening or commenting on pull requests or issues. Learn more about blocking a user.
Summary
minimateplus.histogram_codec.half_period_to_hz(and_FREQ_NUMERATOR = 512) assumes a histogram sampled at 1,024 sps: freq = 512 / half-period. Frequency is really (sample rate / 2) / half-period. So the helper is 2x low at 2,048 sps and 4x low at 4,096 sps.Measured (2026-10-26, BE9441)
K441LTOK.QZ0, whose export says "Sample Rate : 2048 sps": 66/66 frequencies match its export with 1024/hp. With 512/hp they're half.K441LTON.900, "Sample Rate : 4096 sps": 3,398/3,398 intervals match with 2048/hp (decoded with the #47/#49 reader).Impact today: none found (latent)
git grepondevfinds no production caller. Histogram frequencies shown by SFM, the sidecar and the PDF come from Blastware's paired report (zc_freq_hz), not from the half-periods. The helper is used by its own tests, andanalysis_idf/idfh_decode.pyand themicromate/idf_file.pydocs also say 512/hp; those are worth checking for Thor's own rates.Fix
Take the sample rate as a parameter, read from the file's setup or the decoded event, rather than a constant. It must be done before anything computes frequencies from half-periods, e.g. a histogram download with no paired report, which is what SFM's own MiniMate download produces.
Fixed on
dev(merge31231d7, fix2b698e7). Ships in the next release.half_period_to_hz(halfp, sample_rate=1024)now computes(sample_rate / 2) / halfp. The fixed 512 was correct at 1024 sps only._XML.XMLreports on DL2: 527,915 / 527,915 frequency cells at 1024 sps and 1,725 / 1,725 at 2048 sps.N/Afor a half-period of 0>100(>200at 2048) at 5 samples or fewer<1.0below 1 Hz.h5(/intervals/half_period/<ch>), so frequencies can be recomputed at any sample rate.Protocol reference: Appendix D.6.9.