View File
@@ -686,24 +686,19 @@ def write_blastware_file(
# Probe frame: always process regardless of classification.
# It holds the STRT record; probe_skip positions us past it.
skip = probe_skip
elif ftype == "probe_or_strt":
# Real duplicate probe frames should be skipped (very rare).
log.warning(
"write_blastware_file: frame %d classified as probe_or_strt — skipping",
fi,
)
continue
else:
# Waveform chunks, metadata/compliance frames, and unknown frames are all
# included. The A5 stream is collected with stop_after_metadata=True +
# extra_chunks_after_metadata=1, so body_frames contains:
# [0] probe frame
# [1..N] waveform ADC chunks
# [N+1] first compliance frame (contains "Project:", "Client:", etc.)
# [N+2] second compliance frame (continuation of compliance block)
# All of these contribute to the body; the 26-byte footer is separated out
# at the end. Do NOT gate on metadata classification here — the compliance
# block spans 2 frames and skipping frame N+2 produces a truncated file.
# ALL subsequent frames are included unconditionally — no filtering on
# frame type. In the A5 stream, frame 0 is always the probe response;
# frames 1+ are always data (waveform chunks, compliance config, or
# compliance continuation). Classification is for logging only.
#
# DO NOT gate on classify_frame() here:
# - "probe_or_strt" at fi>0 is always a false positive — ADC binary
# data can coincidentally contain b"STRT\xff\xfe" (confirmed from
# live capture: frames 1 and 5 matched on event key=01110000).
# - "metadata" frames must be included (compliance config body).
# - The compliance block spans 2 frames; skipping either produces a
# truncated file that Blastware rejects.
skip = 13 if fi == 1 else 12