@@ -567,4 +567,5 @@ Implementation steps (concrete):
|
||||
- [ ] RV55 DCD/DTR — newer RV55 firmware doesn't assert DCD by default; units don't resume monitoring after call-home disconnect (`--restart-monitoring` flag deferred).
|
||||
- [ ] **NULL-timestamp duplicate-row dedup.** A small handful of events (2 known on prod as of 2026-05-22) have `events.timestamp IS NULL` because the codec couldn't extract a timestamp from the binary footer. The `UNIQUE(serial, timestamp)` constraint doesn't fire on `NULL` (SQL semantics: `NULL ≠ NULL`), so every `--force` backfill INSERTs a new row instead of UPSERTing the existing one. Cleanup: a one-shot SQL query that keeps only the newest row per `(serial, blastware_filename)` and deletes the rest. Longer-term: extend the unique key to `(serial, COALESCE(timestamp, blastware_filename))` or reject inserts with NULL timestamp.
|
||||
- [ ] **Histogram body sub-format with `byte[5] != 0`.** ~3 events on prod (`T190LD5Q.LD0H`, `O121L4L1.GU0H`) use a histogram body my walker doesn't recognize — the first block has `byte[5] = 0x01` or `0x07` instead of `0x00`, and the entire body lacks the `1e 0a 00 00` tail signature. Codec returns 0 valid blocks; their DB PVS comes from the bw_report ASCII overlay (which BW computed from the same binary, so the DB columns are correct). Only the `.h5` waveform plot is empty. Cracking the sub-format would unlock the plot. Needs binary+ASCII pairs from a few `byte[5]!=0` events; same RE approach as the K558 case.
|
||||
- [ ] **Histogram body sub-format with `byte[5] == 0x00` but undecodable.** Observed 2026-05-28 on BE17353 (S353) events: `S353L4H2.FZ0H`, `S353L4H2.P00H`, `S353L4H3.7O0H`, `S353L4H3.E10H`. Body starts `00 00 00 01 0a 00 XX 00 ...` which LOOKS like a valid histogram block header (marker 0x000a at byte[4:6] ✓, byte[5]=0x00 normal-format ✓), but the walker finds zero data blocks across the whole body. Likely an extra header before the block stream OR a different tail signature than `1e 0a 00 00`. Smaller body lengths (1900-2100 bytes) suggest these may be short-recording histogram variants. Same operational impact as the byte[5]!=0 case: event ingests cleanly, DB peaks correct via bw_report overlay, only the chart is empty. Worth dumping a hex view of one body to diagnose.
|
||||
- [ ] **Sensor-check waveform extraction from the BW binary.** BW's Event Report PDFs include a narrow panel on the right side of the waveform plot showing each channel's response to the sensor self-check signal (a damped sinusoid for geo, sawtooth-at-test-freq for mic). Our parser captures the test RESULTS (`test_freq_hz`, `test_ratio`, `test_amplitude_mv`, `test_results` pass/fail) and the PDF + modal display them as text — but BW's per-sample sensor-check waveform isn't accessible to us today. Two paths to add it: (a) RE the binary to find where the sensor-check samples are stored — could be a section before STRT, after the footer, or in a separate sub-record; protocol reference doesn't currently mention it. (b) If samples aren't in the binary, synthesize a representative waveform from the test parameters (damped sinusoid at `test_freq_hz` with damping from `test_ratio`). Path (a) is the honest answer; path (b) is decorative. Until either lands, the text-only sensor-check display in the report is fine.
|
||||
|
||||
Reference in New Issue