Release v0.32.0 — event times you can trust, and Series 4 mapped #54

Merged
serversdown merged 124 commits from dev into main 2026-10-27 11:01:01 -04:00
2 changed files with 89 additions and 1 deletions
Showing only changes of commit 04b1ef3e04 - Show all commits

No files matched your search

+9 -1
View File
@@ -236,11 +236,19 @@ class Link:
arrow = "THOR->unit" if is_request else "unit->THOR"
last = time.time()
while not stop.is_set():
timed_out = False
try:
data = src.recv(4096) if isinstance(src, socket.socket) else src.read(4096)
except TimeoutError:
timed_out = True
# socket.timeout subclasses OSError, so it MUST be caught first.
# Treating it as a dead socket closes the connection after 200 ms
# of quiet -- which is exactly what `blackhole` produces, so the
# relay killed the link it was supposed to be faking a fault on.
data = b""
except OSError:
break
if isinstance(src, socket.socket) and data == b"":
if isinstance(src, socket.socket) and data == b"" and not timed_out:
self.say(f"{arrow}: peer closed the connection")
break
if not data:
+80
View File
@@ -1758,6 +1758,86 @@ Three things this argues for, all cheap:
3. **Bound every operation with its own timeout**, independent of TCP's. Do not
rely on the socket to report a dead peer.
## Reproduced: THOR stops polling after a connection drops mid-download
**2026-09-25, one trial, on the bench link.** This is the failure the operator
described in the field on UM12947 — *"just wouldn't stay connected… clicking the
little refresh button did nothing… no way to view the status of a connection
attempt."*
### What was done
THOR was downloading events. Partway through the bulk transfer the link was
faulted, the connection died, and the link was then fully restored.
⚠ **What THOR actually experienced was a TCP close mid-download**, not the silent
link that was intended — `mm_link.py` had a bug (`socket.timeout` subclasses
`OSError`, so 200 ms of quiet was mistaken for a closed socket). Fixed, but the
run stands as a **drop-mid-download** test, which is arguably the more realistic
case: a modem losing its tower often does produce a real close.
### What happened
```
13:02:49.0 THOR connects, bulk download running (165 BULK_DOWNLOAD frames in)
13:02:50.0 link faulted -> connection dies mid-transfer
13:03:10.4 THOR reconnects once, 20 s later, sends SUB_1F (advance event
pointer) — an attempt to resume
13:03:10.8 that attempt dies too
13:03:33.3 link fully restored and healthy
... 48 s of complete silence ...
13:04:21.4 operator clicks Refresh -> full 11-command check, every response
correct, unit perfectly healthy
... 2 min 6 s of complete silence ...
13:06:27 still nothing. That refresh is the ONLY connection since 13:03:10.
```
Before the fault THOR was connecting every 30 s without a miss for over an hour.
### What this establishes
1. **One retry, then give up.** THOR retried once after 20 s and stopped. No
backoff, no further attempts.
2. **The automatic poll loop dies with it.** Not just the download — the 30 s
connection check and 60 s status check both stopped entirely.
3. **It does not recover when the link returns.** Three minutes of healthy link
produced zero connection attempts.
4. **Refresh works, but only once.** The manual check succeeded completely —
all eleven commands, correct responses. It did **not** restart the automatic
loop; two minutes later there was still nothing.
⚠ **Point 4 is the dangerous one.** Refresh makes the UI report a healthy unit
while nothing is actually watching it. The operator sees a successful check and
moves on; the background loop stays dead. That is worse than a refresh button
that plainly fails, because the failure is *silent and looks like success*.
It also explains why the field symptom is hard to characterise: the unit is
perfectly reachable the whole time. Poke it and it answers. Nothing is wrong
with the unit, the modem, or the link — THOR has simply stopped asking, and says
nothing about it.
### Design consequences for SFM
1. **Retry must be unbounded with backoff**, never one-and-done. A transient
link fault should not take a unit out of service until a human notices.
2. **A manual check must restart the automatic loop**, or the UI must state
clearly that automatic checking is stopped. A green tick that means "it
worked when you asked" is a trap.
3. **Surface the poll loop's own state** — last successful check, last attempt,
next scheduled attempt, consecutive failures. All four were invisible here,
and every one of them would have made this diagnosable in seconds.
4. **Distinguish "unit unreachable" from "we stopped checking."** They present
identically in THOR and have completely different causes and fixes.
### Caveats
- **One trial.** Not yet repeated, and not yet tried with a true silent link
(`blackhole` with the fixed tool) or with a clean `drop`.
- THOR's UI state during the dead window was not recorded — worth capturing on a
repeat, since what the operator *sees* is half the problem.
- Whether a THOR restart is required, or whether it eventually recovers on a
longer timescale, was not tested.
## Thor's conventions vs the protocol's requirements
**SFM is not meant to reimplement Thor.** Thor is the only available teacher of