@@ -2119,20 +2119,40 @@ FTDI is VID `0403`, Prolific is `067b`. Note also that counterfeit FTDI chips
are common in cheap cables — they carry FTDI's VID but may not behave like one,
and an embedded host with a single driver is far less forgiving than Linux.
### Does this explain the 2026-09-22 field outage?
### ✅ This accounts for the 2026-09-22 failure
⚠ **Not on the timeline as reported.** A Prolific cable does not fail
*gradually* — it never enumerates, so the modem port never works at all. The
unit was described as working at first and degrading.
An earlier draft of this section said the timeline did not fit, because the unit
was described as *working at first and then degrading* — which a Prolific cable
cannot do, since it never enumerates at all.
There is one story where it fits: if the initial success was over a **different
path** — the USB **PC** port, or a bench test before deployment — that would work
regardless of which serial cable was attached. The modem path would then have
been broken from the moment it was deployed, and "it worked and then stopped"
would be a recollection conflating two connection types days after the fact.
**The timeline was the thing that needed correcting, not the finding.** From the
operator, 2026-09-25:
Plausible, unverified, and recorded as such. Identifying that unit's cable would
settle it.
1. Initial setup — **one** modem, **one** cable. Worked: configs sent, status
read, no trouble.
2. Two Micromates then had to be deployed, so a **second cable** was fetched to
run both at once.
3. **Only one of the two ever worked.** The other would not talk over its modem
at any point.
4. That unit was never deployed — a **MiniMate Plus was put out in its place**,
and the Micromate came back to the bench.
5. The cable on that bench unit is a **Benfei (Prolific PL2303)**.
So nothing degraded. The "worked at first" was the original single-cable setup;
the failure began when the pair was split across two cables and one of them was
the wrong chipset. **One working and one not, set up side by side, is the
signature of a mixed cable supply** — not of a unit fault.
⚠ Still worth confirming: whether that cable travelled home *with* the unit, or
was picked up separately at the bench. If it travelled with it, there is no
inference left. Either way the FTDI cable arriving 2026-09-26 settles it — same
unit, same modem, one variable.
**Corollary worth knowing.** The standing workaround — *"just deploy a Series III
instead"* — works partly because a **MiniMate Plus has a DB-9 port directly on the
unit.** No USB-to-serial adapter anywhere in the path, so there is no chipset to
get wrong. That workaround has been quietly routing around this exact failure
mode.
### How this was isolated — the method is reusable