@@ -1301,6 +1301,125 @@ Worth noting the histogram (`…81`) and the loudest waveform (`…84`) report
the histogram's single 1-minute interval spans the whole thumping session, so
its maximum should equal the loudest event in it.
## What the THOR manual settles about the ACH session (2026-09-24)
Source: `manuals/723U0201 THOR Operator Manual Rev 08.pdf` §6.2, §3.6.
⚠ **This is vendor documentation, not observed bytes.** It tells us the shape of
the session and the vocabulary; it does not give opcodes. Treated as a strong
prior, not as confirmed protocol.
### 🔑 A unit does NOT learn that an event was accepted — the server decides
This document previously listed, as the thing *gating any homebrew receiver*:
> how a unit announces itself, and **how it learns an event was accepted so it
> stops re-sending it.**
**That was the wrong question.** There is no acknowledgement mechanism to
discover, because the unit is not tracking what has been collected. Per §6.2.2.2
the ACH session is a list of **server-chosen actions**, and two of them are
independent:
| ACH action | what it does |
|---|---|
| **Copy events** | downloads events — *"Only applies to events not previously downloaded"* |
| **Copy monitor log** | downloads the monitor log |
| **Delete events and Logs from Unit** | **explicitly** deletes them from the unit |
| **Set Date/Time** | unit synchronises its clock **from the computer** |
| Send Events / Schedule to Vision | Instantel cloud, not relevant to us |
"Not previously downloaded" is **computer-side bookkeeping**. The unit keeps its
events until a server tells it to erase them, and the manual's own warning proves
the two are decoupled:
> ⚠ *"If you enable 'Delete Events and Logs from Unit' but disable 'Copy Events'.
> The events and logs will be deleted without being uploaded."*
A server that never issues the delete simply re-reads the same events forever.
**This is exactly the model our Series III ACH server already implements** —
`ach_state.json` with `downloaded_keys` / `max_downloaded_key`, and erase as a
separate deliberate step. No new mechanism is needed for Series IV.
So a homebrew receiver needs: accept the connection, identify the unit, walk the
events (already solved — `0x08`/`0x1E`/`0x0A`/`0x5A`), keep our own high-water
mark, and *optionally* erase. **The erase opcodes are the only genuinely missing
piece**, and they remain on the unsafe list.
### The session is server-driven
Which matches the firmware's state machine and its
`CMD_EXIT_CALL_HOME_DELETE_EVENTS_START_MONITORING` /
`Call Home Deleting Events` strings: the unit dials in, then waits to be told
what to do, and returns to monitoring when the server is finished.
Scheduled ACH and event-triggered ACH behave differently (§3.6.1):
- **Event-triggered** (ACH enabled on the unit, an event occurred) — *"Records
events + transfer data, no stopping to monitor."* Governed by **Monitoring
While Calling Home**; with MWCH enabled *"the monitor log will not be copied,
events will not be deleted, and time will not synchronize"*.
- **Scheduled** — *"Stop monitoring + transfer data (or delete events, or
synchronize)."* Monitoring stops and in-progress events complete first.
⚠ Worth noting for SFM: with MWCH on, an event-triggered session **cannot**
delete or sync. A receiver that relies on erase to avoid re-reading will
silently never erase on those units. Our high-water mark must be the primary
mechanism, with erase as an optimisation — which is how Series III already does it.
### Session Time Out is unit-side only
§6.2 is explicit that THOR configures ACH on both ends *"with one exception; the
Session Time Out. This must be configured directly on the unit."* That matches
the firmware's `CallHome.SessionTimeout` field, and means it lives in
`callhome.MMB` rather than anywhere THOR reaches — one more reason to read that
file with `0x94`.
### Unit identification is by serial number, with wildcards
§6.2.2.2: filters match against the serial number the unit presents, `*`
wildcards allowed, best-match wins — `UM*` all Micromates, `MP*` all Minimate
Pros, `BE`/`BC` Minimate Plus variants.
So **the unit announces its serial early enough for the server to route on it.**
`SUB 0x15` returns the serial and is in Thor's standard preamble, which is
consistent, though the inbound direction has still never been observed.
⚠ The manual's worked example contradicts its own table — it says *"To filter
Micromate units type MP*"* and *"To filter Minimate Pro units type UM*"*, which is
backwards. The table is right. Noted so nobody copies the error.
### Thor requires Idle for configuration
§6.2.1 step 3: *"The Monitoring Mode must be 'Idle'."* Independent confirmation
that the greyed-out send observed on the bench is deliberate Thor policy, applied
to ACH setup as well as compliance setup — and still not evidence the device
refuses.
### The schedule's actions, from the UI side
§3.6 lists exactly **four** actions THOR exposes: Start monitoring, Stop
monitoring, Self-check, Auto Call Home. The firmware has **five** — it also has
a setup-less `DUTYCYCLE_START_MONITOR`.
§3.6.2 step 8 confirms the coupling is Thor's own requirement: *"Select the
appropriate Action and the Unit Setup. (A Unit Setup must exist…)"* — while §3.6.2
step 1 notes *"The unit will execute any actions in a schedule using its current
settings."* The two statements sit a paragraph apart and pull in opposite
directions, which is consistent with `START_MONITOR` existing and THOR never
emitting it.
Also from §3.6: schedules are **Day or Week** ("Select Day… Select Week"), have a
**Repeat Daily / Repeat Weekly** flag, carry a Name, Description and Unit Type,
and *"Saving a schedule will only store it on the computer, it must still be sent
to the unit and enabled"* — which is why the capture shows `0x8E` (send) and
`0x47` (enable) as separate steps.
Those are the fields to look for when the schedule entry is finally decoded:
**action, setup name, time, day-or-week, day selection, repeat.** The one
captured entry (`03 00 00 00 0f 03 02 …`) has seven bytes before the name, which
is the right order of magnitude for that field list.
## Thor's conventions vs the protocol's requirements
**SFM is not meant to reimplement Thor.** Thor is the only available teacher of
@@ -1460,11 +1579,16 @@ Also unknown:
- Whether `0x10` bytes inside **request params** need stuffing. (Write-frame
**data** stuffing *is* now settled — `10 XX` → `XX`; see *The write path*.)
- Everything about the **call-home session** — the device-initiated direction
has not been observed at all. Specifically: how a unit announces itself,
and **how it learns an event was accepted so it stops re-sending it.**
That last question gates any homebrew receiver and cannot be answered over
USB.
- The **call-home session's bytes** — the device-initiated direction has still
not been observed at all, and cannot be over USB.
✅ **The second half of this item is resolved** (2026-09-24, from the THOR
manual): "how it learns an event was accepted so it stops re-sending it" was
the wrong question — **it does not learn.** Collection state is server-side
bookkeeping and erase is a separate, optional, server-issued action. See
*What the THOR manual settles about the ACH session*. What remains unknown is
the framing of the inbound session and the **erase opcodes**, not any
acknowledgement mechanism.
---