Release v0.32.0 — event times you can trust, and Series 4 mapped #54
@@ -2308,7 +2308,57 @@ events (already solved — `0x08`/`0x1E`/`0x0A`/`0x5A`), keep our own high-water
|
||||
mark, and *optionally* erase. **The erase opcodes are the only genuinely missing
|
||||
piece**, and they remain on the unsafe list.
|
||||
|
||||
### The session is server-driven
|
||||
### ✅ OBSERVED 2026-10-14 — THOR's ACH side, and it is POLL
|
||||
|
||||
First capture of THOR's half of a Micromate call-home, via `ach_mitm.py` between
|
||||
UM12947's modem and a THOR 1.5.0.29 ACH server on port 8070.
|
||||
|
||||
```
|
||||
unit -> THOR 60 B " \nRADIO RING \nRADIO RING \nRADIO RING \nRADIO RING"
|
||||
THOR -> unit 84 B 4 x 41 02 10 10 00 5b 00 00 30 00 00 00 00 00 00 00 00 00 00 9b 03
|
||||
```
|
||||
|
||||
**THOR sends `POLL` (`SUB 0x5B`, offset `0x0030`) — and nothing else.** Four
|
||||
times over ~21 seconds, then it gives up. It does **not** send a greeting, does
|
||||
not answer the `RADIO RING`, does not send `CONNECT`, and does not wait to be
|
||||
spoken to beyond its initial silence.
|
||||
|
||||
🔑 **That POLL is byte-identical to the one `micromate.protocol` builds.**
|
||||
Verified: `build_request(SUB_POLL, 0x0030)` reproduces all four frames exactly.
|
||||
|
||||
**So the ACH session is pull, and our receiver already implements it correctly.**
|
||||
`bridges/mm_ach_server.py` does what THOR does. The "inbound call-home session"
|
||||
was never a separate protocol — it is the ordinary command set on an inbound
|
||||
socket, exactly as Series III's 72 captured sessions suggested.
|
||||
|
||||
### ⚠ But the unit answered neither — and that is the open problem
|
||||
|
||||
In the same capture the unit sent **only** `RADIO RING`, four times, and never a
|
||||
protocol frame. THOR polled four times and got nothing. Our own server, in three
|
||||
earlier attempts the same afternoon, saw the identical thing.
|
||||
|
||||
**The vendor's own software fails the same way we do**, which eliminates the
|
||||
receiver as a suspect and places the fault between the modem and the unit.
|
||||
|
||||
What is established about that fault:
|
||||
|
||||
| | |
|
||||
|---|---|
|
||||
| cellular link | ✅ healthy — TCP connect in 151 ms, outbound dial succeeds |
|
||||
| modem → us | ✅ bytes arrive |
|
||||
| unit serial TX | ✅ *something* reaches us — the `RADIO RING` text |
|
||||
| unit protocol mode | ❌ never entered; no frame ever sent |
|
||||
| cable | FTDI, physically checked, cold-booted with it attached |
|
||||
| modem serial config | 115200 8N1, no flow control, PAD/TCP — matches spec |
|
||||
|
||||
⚠ `"RADIO RING"` is **the literal string in this unit's own `0x2C` call-home
|
||||
config** (the 40-byte dial-string field). Whether the unit emits it or the modem
|
||||
does is **not yet established** — the cheap disambiguation is to disconnect the
|
||||
unit and see whether the string still appears.
|
||||
|
||||
**Next step is a config diff, not more protocol work.** The deployed fleet runs
|
||||
call-home over PAD successfully, so a working unit's modem settings are the
|
||||
reference. Compare them against this one.
|
||||
|
||||
Which matches the firmware's state machine and its
|
||||
`CMD_EXIT_CALL_HOME_DELETE_EVENTS_START_MONITORING` /
|
||||
|
||||
Reference in new issue
Block a user