Release v0.32.0 — event times you can trust, and Series 4 mapped #54
@@ -442,6 +442,13 @@ memory 15,000,000 total and free (no events stored).
|
||||
scan targets.
|
||||
12. **The geophone scale factor is `3.10308`**, exactly half Series III's
|
||||
`6.206053`, with an ADC of 10,000 counts per volt.
|
||||
13. **The monitoring flag is `0x0E`**, where Series III uses `0x10` — and it
|
||||
sits at `SUB 0x1C` `data[12]`. A second indicator lives at `SUB 0x49`
|
||||
`data[11]` (`0x02` monitoring), which Series III has no equivalent of.
|
||||
14. **Setup files are enumerated** with a `0x3F`/`0x40` first/next walk.
|
||||
Series III has one config and nothing to enumerate.
|
||||
15. **`SUB 0x1C` carries the device clock** (day/month/year/h/m/s at
|
||||
`data[13:21]`). Nothing else read so far reports the unit's own time.
|
||||
|
||||
---
|
||||
|
||||
@@ -913,6 +920,118 @@ a create and an overwrite. We have never seen this protocol report a *failed*
|
||||
write, so **do not treat a zero ack as proof a write was applied.** Read the
|
||||
config back and compare; `SUB 0x41` plus `SUB 0x1A` make that cheap.
|
||||
|
||||
## Monitoring control and the setup list (2026-09-24)
|
||||
|
||||
Capture: `bridges/captures/9-24-26 - micromate2/*_turn_on_monitormode_*`.
|
||||
Thor started monitoring, listed the unit's setups, and stopped monitoring.
|
||||
**40 request frames and 40 responses, every checksum valid.**
|
||||
|
||||
### Thor's per-operation preamble
|
||||
|
||||
Thor re-runs this before *every* operation — three times in this one capture:
|
||||
|
||||
```
|
||||
POLL (0x5B) → SERIAL (0x15) → 0x49 → POLL (0x5B) → <the operation>
|
||||
```
|
||||
|
||||
A client should mirror it. Note `POLL` here carries `offset = 0x0030` (its data
|
||||
length), not `0xFFFF` — `POLL` is the one read Thor still addresses by length.
|
||||
|
||||
### `SUB 0x96` / `0x97` — start and stop monitoring ✅
|
||||
|
||||
Identical to Series III, including the acks:
|
||||
|
||||
| request | ack | effect |
|
||||
|---|---|---|
|
||||
| `0x96` | `0x69` | **start monitoring** |
|
||||
| `0x97` | `0x68` | **stop monitoring** |
|
||||
|
||||
Both are bare frames — no params, no data — and both ack with the usual 16-byte
|
||||
zero-data response. Thor follows each with a `SUB 0x1C` status read to confirm.
|
||||
|
||||
### `SUB 0x1C` — monitor status, 55-byte data
|
||||
|
||||
```
|
||||
data[12] monitoring flag 0x0E monitoring / 0x00 idle
|
||||
data[13] day
|
||||
data[14] month
|
||||
data[15:17] year, uint16 BE
|
||||
data[17] ⚠ unidentified — 32 while monitoring, 100 when idle
|
||||
data[18] hour ─┐ device clock, verified against the capture's
|
||||
data[19] minute │ own wall time (19:12:25 → 19:13:34 EDT)
|
||||
data[20] second ─┘
|
||||
data[-8:-4] memory total, uint32 BE = 15,000,000 bytes exactly
|
||||
data[-4:] memory free, uint32 BE
|
||||
```
|
||||
|
||||
⚠ **The monitoring flag is `0x0E`, not Series III's `0x10`.** Do not reuse the
|
||||
Series III constant. Only five bytes differ between the monitoring and idle
|
||||
responses: the flag, `data[17]`, the clock, and the memory-free field.
|
||||
|
||||
Memory free dropped by exactly **4,096 bytes** across the ~70-second monitoring
|
||||
session — monitoring allocates as it runs, so free memory is not a stable value
|
||||
to compare against.
|
||||
|
||||
The device clock is free here, on a command Thor already sends. That is worth
|
||||
having: nothing else read so far reports the unit's own time.
|
||||
|
||||
### `SUB 0x49` → `0xB6` — a cheap state check
|
||||
|
||||
16-byte data, in Thor's preamble before every operation:
|
||||
|
||||
```
|
||||
05 00 00 00 00 00 00 00 00 00 00 [ST] e8 00 0b 00
|
||||
↑ data[11]: 0x02 monitoring, 0x00 idle
|
||||
```
|
||||
|
||||
**A second monitoring indicator, in a 21-byte response instead of `0x1C`'s 60.**
|
||||
Different encoding from `0x1C`'s flag (`0x02` vs `0x0E`), so they are separate
|
||||
fields, not the same byte read twice. For a polling client this is the cheaper
|
||||
of the two, and Thor evidently treats it as the routine one.
|
||||
|
||||
### `SUB 0x3F` / `0x40` — walking the setup-file list ✅
|
||||
|
||||
The same first/next shape as Series III's `1E`/`1F` event walk, applied to
|
||||
setup files:
|
||||
|
||||
| request | ack | meaning |
|
||||
|---|---|---|
|
||||
| `0x3F` | `0xC0` | **first** setup record |
|
||||
| `0x40` | `0xBF` | **next** setup record; repeat until the name is empty |
|
||||
|
||||
Every record is 266 bytes of data and carries **nothing but the name**:
|
||||
|
||||
```
|
||||
ff 00 00 00 00 00 00 00 00 00 00 <null-terminated name> 00 …
|
||||
└──────────── 11-byte header ─────┘
|
||||
```
|
||||
|
||||
The walk ends on a record whose name is empty — 24 records for 23 setups.
|
||||
`factory.MMB` comes first, from `0x3F`.
|
||||
|
||||
**There is no active-setup flag in the list.** The header is byte-identical on
|
||||
every record including the terminator, and the tail is all zeros. The active
|
||||
setup is identified only by `SUB 0x41`, whose response uses this exact record
|
||||
format. (On the unit's own screen the active setup is marked with a trailing
|
||||
asterisk — that is a UI decoration, not a field.)
|
||||
|
||||
`TEST1.mmb`, created over the wire earlier the same day, appears in the list and
|
||||
is what `0x41` reports as active — independent confirmation that a written setup
|
||||
becomes a real, enumerable file.
|
||||
|
||||
### Thor refuses to send a setup while a unit is monitoring
|
||||
|
||||
Send-to-unit is **greyed out in Thor's UI** when the unit is monitoring, and
|
||||
nothing is transmitted — this capture contains no `0xDA` or `0x71` at all.
|
||||
|
||||
That is a Thor-side policy, not a device refusal: nothing observed suggests the
|
||||
Micromate would reject the write. It squares with the earlier finding that a
|
||||
push to the **active** setup overwrites silently — Thor is preventing exactly
|
||||
the footgun the protocol leaves open.
|
||||
|
||||
**Any client we write should adopt the same rule**, and it is now cheap to
|
||||
enforce: check `0x49` data[11] (or `0x1C` data[12]) before offering a write.
|
||||
|
||||
## Static analysis of the firmware (2026-09-23, solo session)
|
||||
|
||||
### Architecture
|
||||
@@ -1061,8 +1180,9 @@ is known; our encoder is unwritten and unproven.
|
||||
|
||||
- **Writes** (`0x68`–`0x83`) — format now known, never sent by us
|
||||
- **Call-home write** (`0x7E` / `0x7F`) — not observed at all
|
||||
- **Erase** (`0xA3` / `0xA2`)
|
||||
- **Start / stop monitoring** (`0x96` / `0x97`)
|
||||
- **Erase** (`0xA3` / `0xA2`) — **the only genuinely untouched destructive path**
|
||||
- **Start / stop monitoring** (`0x96` / `0x97`) — observed via Thor 2026-09-24,
|
||||
acks `0x69` / `0x68`; still never originated by us
|
||||
- `0x1F` (advance event pointer) — non-destructive on Series III but it does
|
||||
move device state, so it is parked with the rest
|
||||
|
||||
|
||||
Reference in new issue