Release v0.32.0 — event times you can trust, and Series 4 mapped #54
No files matched your search
@@ -2067,6 +2067,60 @@ leak is reproducible and attributable to a specific UI action.
|
||||
3. **Log what changed, not what did not.** `timed out: False` 178 times is
|
||||
noise; the five `True` entries are the signal, and they are buried.
|
||||
|
||||
## The Micromate's USB host supports FTDI and CDC-ACM only — not Prolific
|
||||
|
||||
**Established 2026-09-25**, by isolating a bench modem link layer by layer and
|
||||
then confirming against both firmware images.
|
||||
|
||||
### The USB-A port is a HOST port with a fixed driver set
|
||||
|
||||
```
|
||||
usbHostDelete_CDCACM CDC-ACM — the standard USB-serial class
|
||||
usbHostDelete_FTDI FTDI chips (FTDISER handlers, set_line_coding, etc.)
|
||||
usbHostDelete_MFS mass storage (thumb drives)
|
||||
usbHostDelete_PRINTER printers
|
||||
usbHostDelete_HUB / HC / USBH
|
||||
```
|
||||
|
||||
**Identical in `11.0CB` and `11.0BD`** — 11 `FTDISER` strings and 22 `CDCACM`
|
||||
strings in each, and **zero** matches for `prolific`, `pl2303`, `cp210`, `ch34`
|
||||
or `silabs` in either. The firmware line makes no difference here.
|
||||
|
||||
⚠ **So a Prolific PL2303 cable (VID `067b`) cannot work with a Micromate.** The
|
||||
unit has no driver, never enumerates the device, and the serial path simply does
|
||||
not exist. Use an **FTDI** cable (VID `0403`) or a CDC-ACM one.
|
||||
|
||||
### How this was isolated — the method is reusable
|
||||
|
||||
A Micromate on an RX55 was unreachable from THOR. Rather than guess, each layer
|
||||
was eliminated in turn with `bridges/mm_probe.py`:
|
||||
|
||||
| layer | test | result |
|
||||
|---|---|---|
|
||||
| unit's public IP | static APN `mw01.VZWSTATIC` | ruled out |
|
||||
| firewall / trusted IPs | probe from a whitelisted source | **TCP connect ok, 268 ms** |
|
||||
| network path | same | ruled out |
|
||||
| baud | 115200 both ends | ruled out |
|
||||
| unit modem-type setting | set back to `generic` | ruled out |
|
||||
| THOR | probe bypasses it entirely and still failed | ruled out |
|
||||
| **modem TCP→serial** | swapped the unit for a Linux box on the same cable | **POLL arrived byte-perfect** |
|
||||
| **modem serial→TCP** | that box answered with a canned POLL reply | **round trip in 700 ms** |
|
||||
|
||||
The last two are the decisive pair. With a laptop standing in for the unit on
|
||||
the *same cable and modem*, the full round trip works — so the modem, the PAD
|
||||
configuration, the firewall and the network are all clean, and the only element
|
||||
that changed is what sits at the end of the cable.
|
||||
|
||||
`scratch/fake_unit.py`-style substitution is worth remembering: **replace the
|
||||
device with something known-good and re-run the same test.** It converts "the
|
||||
unit is not answering" into "the unit is not receiving", which are very
|
||||
different problems.
|
||||
|
||||
⚠ This explains the **bench** setup conclusively. Whether it explains the
|
||||
2026-09-22 field outage is **not** established — that unit reportedly worked at
|
||||
first and degraded, which a wrong cable would not do. Treat them as separate
|
||||
until the field unit's cable is identified.
|
||||
|
||||
## Known-good RV55 config for a Micromate (2026-09-25)
|
||||
|
||||
Read off a unit **deployed and working for months**. This is the reference to
|
||||
|
||||
@@ -0,0 +1,33 @@
|
||||
"""Pretend to be a Micromate on a serial port: log what arrives, reply to POLL.
|
||||
|
||||
Proves the modem's return path (serial -> TCP) independently of the real unit.
|
||||
"""
|
||||
import os, select, sys, termios, time
|
||||
|
||||
path, baud = sys.argv[1], int(sys.argv[2]) if len(sys.argv) > 2 else 115200
|
||||
B = {9600: termios.B9600, 38400: termios.B38400, 115200: termios.B115200}[baud]
|
||||
fd = os.open(path, os.O_RDWR | os.O_NOCTTY | os.O_NONBLOCK)
|
||||
a = termios.tcgetattr(fd)
|
||||
a[0] = a[1] = a[3] = 0
|
||||
a[2] = termios.CS8 | termios.CREAD | termios.CLOCAL
|
||||
a[4] = a[5] = B
|
||||
a[6] = list(a[6]); a[6][termios.VMIN] = 0; a[6][termios.VTIME] = 0
|
||||
termios.tcsetattr(fd, termios.TCSANOW, a)
|
||||
termios.tcflush(fd, termios.TCIOFLUSH)
|
||||
|
||||
# A real POLL probe reply, captured from UM12947 on 2026-09-24.
|
||||
REPLY = bytes.fromhex("0200c5a4000000000000300000000000000099") + b"\x03"
|
||||
|
||||
print(f"fake unit on {path} @ {baud}; will answer any inbound frame", flush=True)
|
||||
while True:
|
||||
r, _, _ = select.select([fd], [], [], 1.0)
|
||||
if not r:
|
||||
continue
|
||||
data = os.read(fd, 4096)
|
||||
if not data:
|
||||
continue
|
||||
ts = time.strftime("%H:%M:%S")
|
||||
print(f"{ts} IN {len(data):3} B {data.hex(' ')}", flush=True)
|
||||
time.sleep(0.02)
|
||||
os.write(fd, REPLY)
|
||||
print(f"{ts} OUT {len(REPLY):3} B {REPLY.hex(' ')} <- canned POLL reply", flush=True)
|
||||
Reference in new issue
Block a user