@@ -1546,9 +1546,52 @@ Action codes, so far:
|
||||
| `0` | **Auto Call Home** |
|
||||
| `3` | **Start monitoring, with setup** |
|
||||
|
||||
⚠ `[6]` is the one field still unidentified — `2` on the start entry, `16` on the
|
||||
Auto Call Home entry. It is not the name length and not the time. A capture
|
||||
that changes only the **Repeat** checkbox, or switches Day↔Week, would isolate it.
|
||||
### The Repeat flag is folded into `Action` (2026-09-25)
|
||||
|
||||
A capture that changed **only** the *Repeat Daily* checkbox — schedule pulled,
|
||||
repeat disabled, schedule pushed — moved **exactly one byte in the whole
|
||||
session**:
|
||||
|
||||
```
|
||||
record @0 Action 0x03 → 0x02 (repeat ON → repeat OFF)
|
||||
```
|
||||
|
||||
Nothing else moved. Record 2 unchanged, `[6]` unchanged, and `0xDA`, `0x68`,
|
||||
`0x82`, `0x71`, `0x94`, `0x8D` all byte-identical.
|
||||
|
||||
⚠ So **`[6]` is NOT the repeat flag** — the field predicted for that test is still
|
||||
unidentified. And the earlier label on `[0]` was too simple: it is not a plain
|
||||
action index, it carries the repeat behaviour too.
|
||||
|
||||
**Leading hypothesis** — `2` and `3` are the two *setup-bearing start* actions the
|
||||
firmware names, and repeat selects between them:
|
||||
|
||||
| value | action | why |
|
||||
|---|---|---|
|
||||
| `0` | `DUTYCYCLE_CALLHOME` | the 19:30 entry, no setup name |
|
||||
| `2` | `DUTYCYCLE_START_MONITOR_WITH_SETUP` | repeat **off** |
|
||||
| `3` | `DUTYCYCLE_START_MONITOR_WITH_SETUP_STOP_COMPLETE` | repeat **on** |
|
||||
|
||||
That reading is supported by the THOR manual's description of what a *repeating*
|
||||
schedule does on hitting a Start Monitoring event while already monitoring:
|
||||
|
||||
> *"the unit will stop the current monitoring session, run any Auto Call Home
|
||||
> actions, load the compliance setup and continue monitoring."*
|
||||
|
||||
Which is precisely what a name ending `_STOP_COMPLETE` would mean: a repeating
|
||||
start has to terminate the in-progress session first, a one-shot start does not.
|
||||
The firmware action name, the manual's behaviour, and the single byte that moved
|
||||
all agree.
|
||||
|
||||
⚠ **The enum's ordering is NOT known.** The action names were recovered with
|
||||
`strings | sort`, so their source order is lost — do **not** infer that `1` is
|
||||
`DUTYCYCLE_START_MONITOR` merely because it sits between the two known values,
|
||||
tempting as that is. Three of six codes are observed (`0`, `2`, `3`); the
|
||||
remaining three need entries that use those actions.
|
||||
|
||||
⚠ Note also that Thor re-pushed the **entire 2,090-byte config block** for a
|
||||
one-byte schedule change — a third instance of the coupling described in
|
||||
*The schedule↔config coupling is Thor's, not the protocol's*.
|
||||
|
||||
⚠ Also still unknown: whether the file can hold more than the records in use
|
||||
(both captures had every used record contiguous from offset 0), and the remaining
|
||||
|
||||