@@ -1546,9 +1546,52 @@ Action codes, so far:
| `0` | **Auto Call Home** | | `0` | **Auto Call Home** |
| `3` | **Start monitoring, with setup** | | `3` | **Start monitoring, with setup** |
⚠ `[6]` is the one field still unidentified — `2` on the start entry, `16` on the ### The Repeat flag is folded into `Action` (2026-09-25)
Auto Call Home entry. It is not the name length and not the time. A capture
that changes only the **Repeat** checkbox, or switches Day↔Week, would isolate it. A capture that changed **only** the *Repeat Daily* checkbox — schedule pulled,
repeat disabled, schedule pushed — moved **exactly one byte in the whole
session**:
```
record @0 Action 0x03 → 0x02 (repeat ON → repeat OFF)
```
Nothing else moved. Record 2 unchanged, `[6]` unchanged, and `0xDA`, `0x68`,
`0x82`, `0x71`, `0x94`, `0x8D` all byte-identical.
⚠ So **`[6]` is NOT the repeat flag** — the field predicted for that test is still
unidentified. And the earlier label on `[0]` was too simple: it is not a plain
action index, it carries the repeat behaviour too.
**Leading hypothesis** — `2` and `3` are the two *setup-bearing start* actions the
firmware names, and repeat selects between them:
| value | action | why |
|---|---|---|
| `0` | `DUTYCYCLE_CALLHOME` | the 19:30 entry, no setup name |
| `2` | `DUTYCYCLE_START_MONITOR_WITH_SETUP` | repeat **off** |
| `3` | `DUTYCYCLE_START_MONITOR_WITH_SETUP_STOP_COMPLETE` | repeat **on** |
That reading is supported by the THOR manual's description of what a *repeating*
schedule does on hitting a Start Monitoring event while already monitoring:
> *"the unit will stop the current monitoring session, run any Auto Call Home
> actions, load the compliance setup and continue monitoring."*
Which is precisely what a name ending `_STOP_COMPLETE` would mean: a repeating
start has to terminate the in-progress session first, a one-shot start does not.
The firmware action name, the manual's behaviour, and the single byte that moved
all agree.
⚠ **The enum's ordering is NOT known.** The action names were recovered with
`strings | sort`, so their source order is lost — do **not** infer that `1` is
`DUTYCYCLE_START_MONITOR` merely because it sits between the two known values,
tempting as that is. Three of six codes are observed (`0`, `2`, `3`); the
remaining three need entries that use those actions.
⚠ Note also that Thor re-pushed the **entire 2,090-byte config block** for a
one-byte schedule change — a third instance of the coupling described in
*The schedule↔config coupling is Thor's, not the protocol's*.
⚠ Also still unknown: whether the file can hold more than the records in use ⚠ Also still unknown: whether the file can hold more than the records in use
(both captures had every used record contiguous from offset 0), and the remaining (both captures had every used record contiguous from offset 0), and the remaining