Release v0.32.0 — event times you can trust, and Series 4 mapped #54
@@ -1989,6 +1989,84 @@ useless as a staleness indicator precisely when staleness is the problem.
|
|||||||
- Whether a THOR restart is required, or whether it eventually recovers on a
|
- Whether a THOR restart is required, or whether it eventually recovers on a
|
||||||
longer timescale, was not tested.
|
longer timescale, was not tested.
|
||||||
|
|
||||||
|
## THOR leaks event subscriptions — evidence from its own log
|
||||||
|
|
||||||
|
Source: `thor.log.2026-09-22` from the office THOR PC, supplied 2026-09-25.
|
||||||
|
209 lines covering roughly ten hours.
|
||||||
|
|
||||||
|
### What the log contains
|
||||||
|
|
||||||
|
```
|
||||||
|
178x UnitOperatingModeViewModel - Start/stop monitoring request timed out: False
|
||||||
|
6x UnitOperatingModeViewModel - Callback of start/stop monitor request received
|
||||||
|
5x UnitOperatingModeViewModel - Start/stop monitoring request timed out: True
|
||||||
|
3x SchedulerViewModel - Retrieving unit setup ...
|
||||||
|
2x BWLicenseManager - License State: IsKeyValid 0, IsActivated 0, ...
|
||||||
|
```
|
||||||
|
|
||||||
|
85% of a day's logging is one message. Only **12** lines describe an actual
|
||||||
|
operation.
|
||||||
|
|
||||||
|
### The message is emitted N times for ONE event, and N grows
|
||||||
|
|
||||||
|
Grouping the repeated message by **exact timestamp to the millisecond** — so
|
||||||
|
each group is one logical event, not repeated events:
|
||||||
|
|
||||||
|
| time | identical lines |
|
||||||
|
|---|---|
|
||||||
|
| 11:48 | 1–4 |
|
||||||
|
| 13:05 – 13:31 | 1–2 |
|
||||||
|
| 13:36 – 13:40 | 2–4 |
|
||||||
|
| 15:16 | 3 |
|
||||||
|
| 16:03 – 16:07 | **6** |
|
||||||
|
| 16:14 – 16:16 | 4–6 |
|
||||||
|
| **22:00 – 22:06** | **12** |
|
||||||
|
|
||||||
|
**1 → 12 over ten hours of uptime.** Twelve identical lines sharing one
|
||||||
|
millisecond timestamp is not twelve events; it is one event dispatched to twelve
|
||||||
|
handlers.
|
||||||
|
|
||||||
|
### What it is
|
||||||
|
|
||||||
|
A **subscription leak**, and the class name identifies it:
|
||||||
|
`UnitOperatingModeViewModel`. THOR is a .NET/WPF application ("App thread",
|
||||||
|
ViewModel naming), where this is the archetypal leak — a view model subscribes to
|
||||||
|
an event when its view opens and never unsubscribes when the view closes. Each
|
||||||
|
open adds a live handler; every later notification runs them all.
|
||||||
|
|
||||||
|
Consequences that follow directly:
|
||||||
|
|
||||||
|
- N grows with **uptime and usage**, without bound. Ten hours of moderate use
|
||||||
|
reached 12×; a THOR left running for days across a fleet will be far worse.
|
||||||
|
- Every notification performs N× the work — N timers, N callbacks, N state
|
||||||
|
updates racing one another.
|
||||||
|
- **A restart resets N to 1**, which is consistent with the operator's report
|
||||||
|
that only restarting THOR recovers a degraded session.
|
||||||
|
- The only `timed out: True` entries in the file — five of them — sit at the very
|
||||||
|
top, an episode captured just before log rotation.
|
||||||
|
|
||||||
|
⚠ **Claim discipline.** *Established* from this log: the handler count grows.
|
||||||
|
*Strong inference*: it is a subscription leak. **Not established**: that it
|
||||||
|
caused the specific field outage on 2026-09-22. This log does not cover that
|
||||||
|
window, and the connection between leaked handlers and a dead TCP path is
|
||||||
|
unproven.
|
||||||
|
|
||||||
|
### How to confirm it in ten minutes
|
||||||
|
|
||||||
|
Restart THOR, note the burst size for one event, open and close a unit's detail
|
||||||
|
view ten times, then trigger another event and re-count. If the burst grows, the
|
||||||
|
leak is reproducible and attributable to a specific UI action.
|
||||||
|
|
||||||
|
### For SFM
|
||||||
|
|
||||||
|
1. **Unsubscribe on teardown**, or use weak event patterns. This is the single
|
||||||
|
most common long-running-UI defect and it is entirely preventable.
|
||||||
|
2. **Log once per event, not once per handler.** The duplication here is what
|
||||||
|
made the leak visible, which is lucky — but a log that is 85% one repeated
|
||||||
|
line is also a log nobody reads, which is why this went unnoticed for a year.
|
||||||
|
3. **Log what changed, not what did not.** `timed out: False` 178 times is
|
||||||
|
noise; the five `True` entries are the signal, and they are buried.
|
||||||
|
|
||||||
## Thor's conventions vs the protocol's requirements
|
## Thor's conventions vs the protocol's requirements
|
||||||
|
|
||||||
**SFM is not meant to reimplement Thor.** Thor is the only available teacher of
|
**SFM is not meant to reimplement Thor.** Thor is the only available teacher of
|
||||||
|
|||||||
Reference in new issue
Block a user