Release v0.32.0 — event times you can trust, and Series 4 mapped #54
No files matched your search
+23
-10
@@ -134,17 +134,30 @@ def probe(host: str, port: int, timeout: float) -> int:
|
||||
step(2, "POLL", f"NO REPLY in {timeout:.1f} s")
|
||||
print("\nverdict: the MODEM answered but the unit did not.")
|
||||
print(" TCP is fine end to end — something accepted the connection.")
|
||||
print(" What is missing is the serial side. Most likely the modem is")
|
||||
print(" not forwarding to its serial port, which is what a wedged")
|
||||
print(" transparent-TCP session looks like: the slot is held by a")
|
||||
print(" connection that never closed.")
|
||||
print(" What is missing is the serial side. Two quite different")
|
||||
print(" causes produce this, and they are NOT distinguishable from")
|
||||
print(" here:")
|
||||
print("\n 1. SOMEONE ELSE HOLDS THE SESSION. These modems bridge ONE")
|
||||
print(" TCP session to serial at a time. A second connection is")
|
||||
print(" accepted and then simply not forwarded. Confirmed 2026-09-26:")
|
||||
print(" with THOR connected this probe saw exactly this; the moment")
|
||||
print(" THOR disconnected the same probe returned the serial number.")
|
||||
print(" ** Check whether THOR (or anything else) has the unit first. **")
|
||||
print("\n 2. The serial path is genuinely broken — a stale session the")
|
||||
print(" modem never released, a cable the unit cannot enumerate, or")
|
||||
print(" a unit that is off.")
|
||||
print("\n Try, in order:")
|
||||
print(" 1. ACEmanager -> TCP Idle Timeout. If 0/disabled, a stale")
|
||||
print(" session holds the slot forever. 2 minutes is the value")
|
||||
print(" this project standardised on.")
|
||||
print(" 2. Reboot the modem. If that fixes it, the modem was")
|
||||
print(" holding state and the timeout is the permanent fix.")
|
||||
print(" 3. Check the unit's own screen — serial cable, power.")
|
||||
print(" 1. Disconnect any other client and re-probe. If it answers,")
|
||||
print(" it was contention, not a fault.")
|
||||
print(" 2. The cable's chipset. A Micromate drives FTDI and CDC-ACM")
|
||||
print(" only — a Prolific PL2303 gives it no serial port at all.")
|
||||
print(" lsusb: FTDI is 0403, Prolific 067b.")
|
||||
print(" 3. Power-cycle the UNIT with the cable attached (hold power")
|
||||
print(" 5 s, through the two-stage prompt). Its USB host rescans")
|
||||
print(" on cold boot; it may not on hot-swap.")
|
||||
print(" 4. AirLink OS -> TCP Idle Timeout. If 0/disabled, a stale")
|
||||
print(" session holds the slot indefinitely. 2 minutes is the")
|
||||
print(" value this project standardised on.")
|
||||
sock.close()
|
||||
return 5
|
||||
|
||||
|
||||
@@ -2162,6 +2162,52 @@ unit.** No USB-to-serial adapter anywhere in the path, so there is no chipset t
|
||||
get wrong. That workaround has been quietly routing around this exact failure
|
||||
mode.
|
||||
|
||||
### ✅ RESOLVED (2026-09-26) — and it took a cold boot as well as the cable
|
||||
|
||||
Swapping to a genuine FTDI cable (`lsusb`: `0403:6001`, FT232) **did not work on
|
||||
its own.** A probe immediately after the swap returned the same *connected, no
|
||||
reply*.
|
||||
|
||||
**A cold boot of the unit was also required.** Holding the power button for five
|
||||
seconds — through the two-stage prompt that disconnects the internal battery —
|
||||
and powering back up **with the cable already attached**, brought it straight up.
|
||||
THOR at the office connected the moment it finished booting, and an independent
|
||||
probe returned `UM12947, idle` over cellular.
|
||||
|
||||
⚠ **The USB host does not rescan on hot-swap.** The Micromate enumerates its
|
||||
USB-A host port at boot; once it has failed to identify a device there it does
|
||||
not appear to try again. Changing that cable is a power-cycle operation, and
|
||||
anyone swapping one in the field who probes immediately will conclude the new
|
||||
cable is faulty too.
|
||||
|
||||
So the full chain for a Micromate on a modem is:
|
||||
|
||||
1. an **FTDI** or CDC-ACM cable — a Prolific PL2303 gives the unit no serial port
|
||||
2. a **cold boot** with that cable attached
|
||||
|
||||
### ✅ These modems bridge ONE session at a time — confirmed
|
||||
|
||||
Long suspected, never demonstrated. Demonstrated now, by accident:
|
||||
|
||||
| | probe result |
|
||||
|---|---|
|
||||
| THOR connected to the unit | `TCP connect ok` … **`NO REPLY`** |
|
||||
| THOR disconnected, nothing else changed | `reply 68 B`, **`UM12947`**, idle |
|
||||
|
||||
The PAD **accepts** a second TCP connection and then does not forward it. It
|
||||
does not refuse, and it does not close — it simply never bridges.
|
||||
|
||||
⚠ **This means "connected but no reply" has two causes that are indistinguishable
|
||||
from the client side:** a genuinely broken serial path, and *somebody else
|
||||
already has the unit*. `bridges/mm_probe.py` originally reported only the first,
|
||||
which would send a diagnosis in exactly the wrong direction; its verdict now
|
||||
names both and tells you to eliminate contention first.
|
||||
|
||||
**For SFM this is a design constraint, not a footnote.** Our receiver and THOR
|
||||
cannot both hold a unit, and during any migration both will exist. "Another
|
||||
client holds this unit" needs to be a distinct, visible state — not folded into
|
||||
a failure, and certainly not into a green tick.
|
||||
|
||||
### How this was isolated — the method is reusable
|
||||
|
||||
A Micromate on an RX55 was unreachable from THOR. Rather than guess, each layer
|
||||
|
||||
Reference in new issue