Release v0.32.0 — event times you can trust, and Series 4 mapped #54

Merged
serversdown merged 124 commits from dev into main 2026-10-27 11:01:01 -04:00
Showing only changes of commit b9c52442a7 - Show all commits
+71 -10
View File
@@ -15,20 +15,77 @@ with no events stored**.
## The headline
**The Micromate answers Series III command frames.**
**A Micromate running the *Blastware* firmware answers Series III command
frames.**
An unmodified Series III `POLL` (`SUB 0x5B`), built by
`minimateplus.framing.build_bw_frame` with no changes at all, produced a
complete two-step probe/data cycle from a Micromate. Ten Series III read
commands were then tried and **all ten answered**, every one obeying the
Series III response-SUB rule.
complete two-step probe/data cycle. Ten Series III read commands were then
tried and **all ten answered**, every one obeying the Series III response-SUB
rule.
This is not a new protocol. It is close enough to Series III that large parts
of `minimateplus/protocol.py` may apply more or less directly, and the work
ahead is mapping *divergence* rather than mapping from scratch.
⚠ **That qualifier is load-bearing, and it was discovered after the fact.**
Instantel ships the Micromate in two firmware lines:
| firmware | Instantel's own description |
|---|---|
| `11.0CB` | "Utilize with **Blastware**" |
| `11.0BD` | "Utilize with **THOR, Vision, Vision II**" |
The bench unit reports **`11.0CB`** — the Blastware build. So the clean
Series III behaviour above is very likely *because the unit is in Blastware
mode*, not because the Micromate natively speaks Series III. **Nothing here
should be assumed to hold on a `11.0BD` unit until tested.**
This reframes the project. The question is no longer only "what is the
Series IV protocol" but **"which firmware line do we target, and does one of
them let the existing Series III stack drive the whole fleet?"**
---
## Firmware — the variable nobody knew was a variable
This explains a production problem TMI has lived with: two ACH servers, two
machines, and units that will not cross over. It is not a misconfiguration.
**Instantel ships different firmware for different host software**, and the
wire protocol differs with it.
Versions observed so far:
| where | version | notes |
|---|---|---|
| bench unit UM12947, today | **`11.0CB`** | Blastware line — answers Series III |
| corpus, 932 event files | `11.0AK` | produced Thor-collected `.IDFW`/`.IDFH` |
| corpus, 83 event files | `10.90GC` | older; UM12947's own files from Sept 2025 |
Note UM12947 produced `10.90GC` files in production last year and reports
`11.0CB` on the bench now — so **it has been reflashed at some point**, and
firmware is not stable per-unit over time. Any fleet-wide claim needs a
per-unit firmware audit first.
The version is readable over the wire from `SUB 0x01` as two separate ASCII
runs — `"0CB"` then `"11"` — with no single concatenated string.
### The strategic fork
- **Option A — standardise the fleet on the Blastware line.** Every unit,
MiniMate and Micromate alike, then speaks Series III, and the existing
`minimateplus/` stack drives all of it. One protocol, one call-home
receiver. Dramatically cheaper *if* it holds up.
- **Option B — reverse-engineer the Thor line (`11.0BD`) and support both.**
Option A is the shortcut, but it is unproven and carries real unknowns, all
of which are cheap to answer on the bench and expensive to discover later:
1. **What file format does a `11.0CB` unit produce?** If it emits Blastware
binaries rather than `.IDFW`/`.IDFH`, the (now exact) Series III decoder
applies and the IDF codec becomes a legacy path. Not a loss — we have
both — but it changes what the ingest pipeline sees.
2. **Does Thor still work with a `11.0CB` unit?** If not, flashing a
production unit breaks data collection until the replacement path exists.
3. **Are any Micromate-specific capabilities lost** on the Blastware line?
4. **Is the flash reversible in the field**, and what does it cost in downtime?
## How this was obtained
No Thor, no modem, no Windows machine. The Micromate exposes its protocol on
@@ -221,9 +278,13 @@ Also unknown:
## Session provenance
Unit **UM12947**, on the bench via USB, **zero events stored** (memory free ==
total). Read commands only. Every response in this document was checksum-
validated.
Unit **UM12947**, firmware **`11.0CB`** (Blastware line), on the bench via
USB, **zero events stored** (memory free == total). Read commands only.
Every response in this document was checksum-validated.
⚠ Firmware is the single biggest caveat on this document. Every finding here
is from one unit on the Blastware build. A `11.0BD` unit has not been
touched.
An empty unit is a real limitation: `0x08`, `0x1E`, `0x0A` and `0x06` all have
event-dependent payloads that could not be exercised. Recording a couple of