Release v0.32.0 — event times you can trust, and Series 4 mapped #54

Merged
serversdown merged 124 commits from dev into main 2026-10-27 11:01:01 -04:00
2 changed files with 91 additions and 2 deletions
Showing only changes of commit d522d31d63 - Show all commits

No files matched your search

+8 -2
View File
@@ -170,10 +170,16 @@ class FrameSniffer:
return # wait for more bytes
body = self.buf[start:end + 1]
del self.buf[:end + 1]
# sub sits at a fixed spot once the leading framing is skipped
# SUB sits at a fixed spot past the leading framing -- but it is
# DLE-escaped when its own value is 0x02/0x03/0x04/0x10, so a raw
# read reports 0x10 for those. SUB 0x02 was being logged as
# "SUB_10" until this was handled.
off = 5 if self.is_request else 3
if len(body) > off:
yield body[off], len(body)
sub = body[off]
if sub == DLE and len(body) > off + 1:
sub = body[off + 1]
yield sub, len(body)
class Link:
+83
View File
@@ -1595,6 +1595,89 @@ Those are the fields to look for when the schedule entry is finally decoded:
captured entry (`03 00 00 00 0f 03 02 …`) has seven bytes before the name, which
is the right order of magnitude for that field list.
## What THOR's "status check" actually is (2026-09-25)
Captured with `bridges/mm_link.py` standing in for the modem, THOR configured
`Communication: TCP`, **Check connection every 5 s**, **Check status every 5 s**.
### It is eleven commands, not one
```
POLL → DEVICE_INFO → 0x49 → 0x5C → MONITOR_STATUS → SETUP_NAME_READ
→ STORAGE_RANGE → 0x02 → OPERATOR → 0x47 → CALLHOME_CFG
```
Each check opens a **new TCP connection**, runs all eleven exchanges in ~300 ms,
and closes it. Measured over 21 consecutive checks:
| | |
|---|---|
| request payload | **236 B** |
| response payload | **936 B** |
| TCP connect + teardown | ~1,000 B (fresh handshake every time) |
| **per check** | **~2.2 KB** |
### The cost
| cadence | checks/day | per unit |
|---|---|---|
| **every 10 s (as observed)** | 8,640 | **18.8 MB/day — 563 MB/month** |
| every 60 s | 1,440 | 3.1 MB/day — 94 MB/month |
| every 15 min | 96 | 0.2 MB/day — 6 MB/month |
⚠ **On a metered cellular plan this is real money, and most of it is waste.**
A status check re-reads the call-home config, the operator name, the active setup
name and the full device info block **every ten seconds** — none of which changes
between checks. `SETUP_NAME_READ` alone returns 274 bytes each time.
A genuine liveness + state check is **`POLL` + `MONITOR_STATUS`**: two commands,
131 bytes of response. Same information about whether the unit is alive and
whether it is monitoring, for a ninth of the traffic.
### Both intervals at 5 s produces one check every ~10 s
Connection timestamps over three minutes: `11:31:48.7`, `11:31:58.9`,
`11:32:08.9`, `11:32:19.0`, `11:32:29.1`, `11:32:39.2`, `11:32:49.3`,
`11:32:59.4` — a **10.1 s** period, steady.
So *"Check connection every 5 s"* and *"Check status every 5 s"* do not describe
two independent 5-second timers; together they yield one combined pass every ten
seconds. That is a plausible reason changing those fields appears to do nothing:
the relationship between the setting and the observed cadence is not what the UI
implies.
### ⚠ What this means for the "won't stay connected" failure
Because idle polling **opens a fresh connection each time**, a silently-dead link
is *less* dangerous here than expected — a dead socket fails at connect and the
next cycle simply tries again. The earlier hypothesis (THOR wedged on a
half-open socket during polling) is weakened by this.
The exposure is during **operations**, not polling: THOR was observed holding one
connection from **00:30 to 00:47 — seventeen minutes** — while downloading events
and pushing setups. A link that dies silently mid-operation leaves THOR waiting
on a socket the OS will not fail for roughly the default keepalive (~2 h). That
remains the best candidate for a unit that will not come back and where refresh
does nothing.
**Testable with `mm_link.py`:** set `blackhole` *during* a download or config
push rather than while idle, and watch whether THOR ever gives up, whether
refresh emits any bytes, and whether it recovers when `pass` is restored.
### Design notes for SFM
Three things this argues for, all cheap:
1. **Separate liveness from inventory.** Poll `POLL` + `MONITOR_STATUS`
frequently; read config, setup name and call-home settings only when
something says they changed, or on demand.
2. **Show the connection attempt.** Every check here has a visible outcome —
connected, frames exchanged, closed. THOR surfaces none of it, which is why
a failing unit is undiagnosable from the UI. The log this section is built
from took one afternoon to produce and answers questions THOR cannot.
3. **Bound every operation with its own timeout**, independent of TCP's. Do not
rely on the socket to report a dead peer.
## Thor's conventions vs the protocol's requirements
**SFM is not meant to reimplement Thor.** Thor is the only available teacher of