Release v0.32.0 — event times you can trust, and Series 4 mapped #54

Merged
serversdown merged 124 commits from dev into main 2026-10-27 11:01:01 -04:00
Showing only changes of commit d93ebe2322 - Show all commits
+22 -6
View File
@@ -1800,8 +1800,9 @@ Before the fault THOR was connecting every 30 s without a miss for over an hour.
backoff, no further attempts.
2. **The automatic poll loop dies with it.** Not just the download — the 30 s
connection check and 60 s status check both stopped entirely.
3. **It does not recover when the link returns.** Three minutes of healthy link
produced zero connection attempts.
3. **It does not recover when the link returns.** Sixteen minutes of healthy
link produced **no automatic connection attempts at all** — only ones an
operator initiated by hand.
4. **Refresh works, but only once.** The manual check succeeded completely —
all eleven commands, correct responses. It did **not** restart the automatic
loop; two minutes later there was still nothing.
@@ -1813,14 +1814,29 @@ that plainly fails, because the failure is *silent and looks like success*.
### 🔑 "Not polling" and "unreachable" are different states — and THOR conflates them
Demonstrated directly. At **13:10:44**, six and a half minutes after THOR's last
connection of any kind:
Demonstrated directly. At **13:10:44** an independent `POLL` through the same
relay succeeded with a correct response while THOR's automatic polling was dead.
⚠ **A correction, recorded because the first version of this claim was sloppy.**
It originally read "THOR connections since 13:04:22 : 0". That count was an
artifact of a time filter (`13:0[4-9]`) that silently dropped everything from
13:10 onward. THOR *had* connected four times, at 13:10:03–13:10:37.
Inspecting those four shows the conclusion survives — but for a better reason
than the one first given. They were **user-initiated commands, not polling**:
```
THOR connections since 13:04:22 : 0
independent POLL through the same relay, same moment : succeeds, correct response
13:10:03 POLL → SUB_96 (start monitoring) 13:10:05 MONITOR_STATUS
13:10:35 POLL → SUB_97 (stop monitoring) 13:10:37 MONITOR_STATUS
```
Single commands a human clicked, each followed by one status read. Neither the
eleven-command status check nor the three-command connection check appears.
**Automatic polling did not resume**, and by 13:19:53 had been absent for
**16 minutes**. Every THOR connection in that window was something an operator
clicked: the refresh at 13:04:21, then start and stop monitoring at 13:10.
**The unit is reachable. The link is fine. THOR is simply not asking.**
**THOR reports `Connection Status: Connected`.** Captured at 13:15, eleven