Release v0.32.0 — event times you can trust, and Series 4 mapped #54
@@ -1811,10 +1811,38 @@ while nothing is actually watching it. The operator sees a successful check and
|
||||
moves on; the background loop stays dead. That is worse than a refresh button
|
||||
that plainly fails, because the failure is *silent and looks like success*.
|
||||
|
||||
It also explains why the field symptom is hard to characterise: the unit is
|
||||
perfectly reachable the whole time. Poke it and it answers. Nothing is wrong
|
||||
with the unit, the modem, or the link — THOR has simply stopped asking, and says
|
||||
nothing about it.
|
||||
### 🔑 "Not polling" and "unreachable" are different states — and THOR conflates them
|
||||
|
||||
Demonstrated directly. At **13:10:44**, six and a half minutes after THOR's last
|
||||
connection of any kind:
|
||||
|
||||
```
|
||||
THOR connections since 13:04:22 : 0
|
||||
independent POLL through the same relay, same moment : succeeds, correct response
|
||||
```
|
||||
|
||||
**The unit is reachable. The link is fine. THOR is simply not asking.**
|
||||
|
||||
Whatever THOR's UI reports in that window, it is wrong:
|
||||
|
||||
| if it shows | why it is false |
|
||||
|---|---|
|
||||
| connected / OK | nothing has been checked for minutes |
|
||||
| disconnected / unreachable | it **is** reachable — THOR stopped trying |
|
||||
|
||||
The true state is *"I have given up checking this unit"*, and no display in THOR
|
||||
expresses it. So an operator cannot separate **the unit is down** from **the
|
||||
poller is asleep** — and those demand completely different responses: a site
|
||||
visit versus a mouse click.
|
||||
|
||||
This also settles a question the previous section left open. It does not much
|
||||
matter whether stopping after one retry is an intentional design choice or a
|
||||
defect: **the reporting is wrong either way**, because both plausible displays
|
||||
misrepresent reality.
|
||||
|
||||
It explains, too, why the field symptom resisted characterisation. The unit is
|
||||
perfectly reachable throughout. Poke it and it answers. Nothing is wrong with
|
||||
the unit, the modem, or the link.
|
||||
|
||||
### Design consequences for SFM
|
||||
|
||||
@@ -1826,8 +1854,12 @@ nothing about it.
|
||||
3. **Surface the poll loop's own state** — last successful check, last attempt,
|
||||
next scheduled attempt, consecutive failures. All four were invisible here,
|
||||
and every one of them would have made this diagnosable in seconds.
|
||||
4. **Distinguish "unit unreachable" from "we stopped checking."** They present
|
||||
identically in THOR and have completely different causes and fixes.
|
||||
4. **Distinguish "unit unreachable" from "we stopped checking."** Proven above
|
||||
to be different states that THOR cannot tell apart. A unit's displayed state
|
||||
should be one of: *checks passing*, *checks failing* (with the attempt count
|
||||
and last error), or *not being checked* (with why, and a way to resume).
|
||||
Collapsing the last two into one indicator is the root of this whole failure
|
||||
being undiagnosable.
|
||||
|
||||
### Caveats
|
||||
|
||||
|
||||
Reference in new issue
Block a user