@@ -1811,10 +1811,38 @@ while nothing is actually watching it. The operator sees a successful check and
|
|||||||
moves on; the background loop stays dead. That is worse than a refresh button
|
moves on; the background loop stays dead. That is worse than a refresh button
|
||||||
that plainly fails, because the failure is *silent and looks like success*.
|
that plainly fails, because the failure is *silent and looks like success*.
|
||||||
|
|
||||||
It also explains why the field symptom is hard to characterise: the unit is
|
### 🔑 "Not polling" and "unreachable" are different states — and THOR conflates them
|
||||||
perfectly reachable the whole time. Poke it and it answers. Nothing is wrong
|
|
||||||
with the unit, the modem, or the link — THOR has simply stopped asking, and says
|
Demonstrated directly. At **13:10:44**, six and a half minutes after THOR's last
|
||||||
nothing about it.
|
connection of any kind:
|
||||||
|
|
||||||
|
```
|
||||||
|
THOR connections since 13:04:22 : 0
|
||||||
|
independent POLL through the same relay, same moment : succeeds, correct response
|
||||||
|
```
|
||||||
|
|
||||||
|
**The unit is reachable. The link is fine. THOR is simply not asking.**
|
||||||
|
|
||||||
|
Whatever THOR's UI reports in that window, it is wrong:
|
||||||
|
|
||||||
|
| if it shows | why it is false |
|
||||||
|
|---|---|
|
||||||
|
| connected / OK | nothing has been checked for minutes |
|
||||||
|
| disconnected / unreachable | it **is** reachable — THOR stopped trying |
|
||||||
|
|
||||||
|
The true state is *"I have given up checking this unit"*, and no display in THOR
|
||||||
|
expresses it. So an operator cannot separate **the unit is down** from **the
|
||||||
|
poller is asleep** — and those demand completely different responses: a site
|
||||||
|
visit versus a mouse click.
|
||||||
|
|
||||||
|
This also settles a question the previous section left open. It does not much
|
||||||
|
matter whether stopping after one retry is an intentional design choice or a
|
||||||
|
defect: **the reporting is wrong either way**, because both plausible displays
|
||||||
|
misrepresent reality.
|
||||||
|
|
||||||
|
It explains, too, why the field symptom resisted characterisation. The unit is
|
||||||
|
perfectly reachable throughout. Poke it and it answers. Nothing is wrong with
|
||||||
|
the unit, the modem, or the link.
|
||||||
|
|
||||||
### Design consequences for SFM
|
### Design consequences for SFM
|
||||||
|
|
||||||
@@ -1826,8 +1854,12 @@ nothing about it.
|
|||||||
3. **Surface the poll loop's own state** — last successful check, last attempt,
|
3. **Surface the poll loop's own state** — last successful check, last attempt,
|
||||||
next scheduled attempt, consecutive failures. All four were invisible here,
|
next scheduled attempt, consecutive failures. All four were invisible here,
|
||||||
and every one of them would have made this diagnosable in seconds.
|
and every one of them would have made this diagnosable in seconds.
|
||||||
4. **Distinguish "unit unreachable" from "we stopped checking."** They present
|
4. **Distinguish "unit unreachable" from "we stopped checking."** Proven above
|
||||||
identically in THOR and have completely different causes and fixes.
|
to be different states that THOR cannot tell apart. A unit's displayed state
|
||||||
|
should be one of: *checks passing*, *checks failing* (with the attempt count
|
||||||
|
and last error), or *not being checked* (with why, and a way to resume).
|
||||||
|
Collapsing the last two into one indicator is the root of this whole failure
|
||||||
|
being undiagnosable.
|
||||||
|
|
||||||