Release v0.34.0 — Series-4 parity, and most of Blastware's report from the event file alone #59

Merged
serversdown merged 245 commits from dev into main 2026-11-04 18:19:24 -05:00
Showing only changes of commit 55d74c0a7b - Show all commits
+21
View File
@@ -35,6 +35,27 @@ All notable changes to seismo-relay are documented here.
(`backfill_sidecars.py` then `backfill_event_shape.py`) rewrites stored
Sensitive events' peaks and `.h5` files. No schema change.
### Protocol / Documentation
- **`docs/instantel_protocol_reference.md` gains Appendix D.6:** the bytes
and DL2 verification for every field SFM reads from a Blastware event file.
- the record type, `STRT[18]`
- the recording-setup block: sample rate, pre-trigger, record time and the
four notes
- the geophone range
- each histogram interval's PVS²
- the mic scale
- **Retracted in place:**
- `STRT[20]` as the record time: it is `00` on every DL2 file.
- The 2026-08-26 reading of sub-minute histogram records as little-endian:
they are big-endian from byte 5 (#47/#49), and the "2-word tail" is the
PVS². This is corrected in CLAUDE.md too.
- **Measured for #48, on files only:** the 1A "stable anchor"
`be 80 00 00 00 00` is the setup's pre-trigger −0.25 s followed by `00 00`.
It appears only on the 3,886 / 6,541 DL2 waveforms recorded at exactly
−0.25 s, and on no histogram. The live 1A read is still unmeasured.
- **CLAUDE.md "Where things stand"** now reflects the range fix.
- Docs only: no code change, no migration.
## v0.33.0 — 2026-11-01
**SFM reads Series-3 events from the file alone, and proves it against