Release v0.34.0 — Series-4 parity, and most of Blastware's report from the event file alone #59
@@ -0,0 +1,519 @@
|
||||
# Phase 5: Changing a Unit's Settings by Serial — Implementation Plan
|
||||
|
||||
> **For agentic workers:** REQUIRED SUB-SKILL: Use superpowers:subagent-driven-development (recommended) or superpowers:executing-plans to implement this plan task-by-task. Steps use checkbox (`- [ ]`) syntax for tracking.
|
||||
|
||||
**Goal:** An operator edits a unit's live settings in SFM, by serial, on either series: preview old → new, send once (audited), and see what the unit now holds.
|
||||
|
||||
**Architecture:**
|
||||
- **One pure settings codec for both series** (`micromate/setup_fields.py`), on the measured shared 2,090-byte layout.
|
||||
- **Each series' adapter supplies reads, the plan and the send** to the existing `run_change` core, unchanged.
|
||||
- Its "state" is a read-back verdict: `as asked` / `unchanged` / `differs`.
|
||||
- Series 3 sends through `push_config_raw`; Series 4 through `plan_setup_push`.
|
||||
- Series 4 also reads the unit's schedule, read-only, to refuse a change that a scheduled start would undo.
|
||||
- **One audited route**, `POST /device/settings/change`. The legacy by-host write is retired.
|
||||
|
||||
**Tech Stack:** Python 3 (FastAPI, pytest), vanilla JS tested in Node (`tests/test_webapp_device_routing.py`).
|
||||
|
||||
**Spec:** `docs/superpowers/specs/2026-11-03-sfm-phase5-settings-design.md` (approved by Brian 2026-11-03). Parent spec: `docs/superpowers/specs/2026-10-20-sfm-series4-parity-design.md`.
|
||||
|
||||
## Global Constraints
|
||||
|
||||
- **Worktree and branch:** work in `~/seismo-relay-parity` on `feat/series4-sfm-parity`. Check `git branch --show-current` before every commit; never commit to `main`; push every commit.
|
||||
- **Python:** `/home/serversdown/seismo-relay/.venv/bin/python -m pytest …` from the worktree root.
|
||||
- **The suite has 16 known failures.**
|
||||
- Run the full suite once before Task 1 and save the failure list in the plan workspace as `baseline-failures.txt`.
|
||||
- Before every commit, run the suite, read the failure list, and confirm it equals the baseline.
|
||||
- Commit in a separate call, never chained to the test run.
|
||||
- **No live device traffic** in any task. The bench is after the final review, with Brian's explicit go per send.
|
||||
- Never port 8200.
|
||||
- Never write modem baud or modem type.
|
||||
- Never send `0xA2`.
|
||||
- **`CHANGELOG.md` is not touched** on this branch; it is written on `dev` at the merge.
|
||||
- **No inline JavaScript.** New page logic goes in `sfm/static/device_routing.js` (DOM-free, Node-tested); glue goes in `sfm/static/sfm_webapp.js`.
|
||||
- **`docs/instantel_protocol_reference.md` is CRLF.** Edit it only with the Edit tool. Keep its rows in date order.
|
||||
- **Off-limits (the checker session's files):** `minimateplus/event_file_io.py`, `histogram_codec.py`, `waveform_codec.py`, `bw_xml_report.py`, `decode_check*.py`.
|
||||
- **`TOOL_VERSION` is unchanged:** nothing here changes event decoding. Operational consequence: none; no migration, no backfill.
|
||||
- **Grade every protocol claim** in comments and docs as measured or inferred.
|
||||
- **Mutation checks:** after a mutate/restore, delete the module's `__pycache__/*.pyc` before the confirming run.
|
||||
|
||||
## Review Focus
|
||||
|
||||
1. **A Micromate with no schedule file, or a schedule read that fails.**
|
||||
- A body with no records means no conflict, and the change proceeds.
|
||||
- A read that raises refuses the change in plain words.
|
||||
- Owner: Task 4; tests `test_no_schedule_records_is_no_conflict` and `test_an_unreadable_schedule_refuses`.
|
||||
2. **A float that is stored as f32.** 0.3 reads back as 0.30000001192.
|
||||
- The verdict compares bytes with the image written, never floats, so it reads `as asked`.
|
||||
- Owner: Task 2; test `test_f32_values_read_back_as_asked`.
|
||||
3. **A stale or foreign revision** after a keypad edit, or a preview of another unit.
|
||||
- The send is refused with 409, nothing is sent, and no audit row is written.
|
||||
- Owner: Tasks 4 and 5; tests `test_s4_stale_revision_sends_nothing` and `test_s3_stale_revision_sends_nothing`.
|
||||
4. **Range and trigger changed in one request.** The trigger is checked against the **new** range.
|
||||
- Owner: Task 2; test `test_trigger_checked_against_the_new_range`.
|
||||
5. **Notes at the edges.**
|
||||
- `""` clears a note.
|
||||
- 41 bytes is accepted; 42 is refused; non-ASCII is refused.
|
||||
- Labels are never written.
|
||||
- Owner: Task 2; tests `test_note_edges` and `test_note_labels_are_never_written`.
|
||||
|
||||
---
|
||||
|
||||
## File Structure
|
||||
|
||||
| file | responsibility |
|
||||
|---|---|
|
||||
| `minimateplus/protocol.py` | **Series 3 assembly:** `assemble_compliance_content`, `is_compliance_content`, `MiniMateProtocol.read_compliance_content`. **Writes:** `push_config_raw`'s pre-check raises `ImageRefused`. |
|
||||
| `minimateplus/client.py` | **Added:** `read_compliance_content()` and `read_settings_blocks()`. **Deleted:** `apply_config`, `set_project_info`, `_encode_compliance_config`. |
|
||||
| `micromate/setup_block.py` | **Added:** `with_crc(content)`. |
|
||||
| `micromate/setup_fields.py` (new) | **The shared, pure settings codec:** field registry, `editable_fields`, `check_changes`, `encode_setup`, `field_values`, `settings_state`, `revision`. |
|
||||
| `micromate/schedule.py` (new) | **Pure:** `parse_schedule`, `ScheduleEntry`, `schedule_conflicts`. |
|
||||
| `micromate/protocol.py` | **Added:** `read_file(path)`, using `0x94` then `0x48` pages. |
|
||||
| `micromate/client.py` | **Added:** `read_schedule()`, `get_active_setup_raw()`, `get_prefs_content()`, `get_trigger_content()`, `get_setup_content()`. |
|
||||
| `micromate/opcodes.py` | `ENABLEABLE_WRITES` gains the setup-push SUBs. |
|
||||
| `sfm/device_access/errors.py` | **Added:** `SettingsChanged` and `ChangeRefused`, both 409. |
|
||||
| `sfm/device_access/change.py` | **Added:** `settings_change()`. |
|
||||
| `sfm/device_access/s4.py` | `s4_settings` moves onto the codec. **Added:** `s4_change_settings`. |
|
||||
| `sfm/device_access/s3.py` | `Series3Adapter.settings` moves onto the codec. **Added:** `Series3Adapter.change_settings`. |
|
||||
| `sfm/device_access/access.py` | **Added:** `DeviceAccess.change_settings`. |
|
||||
| `sfm/server.py` | **Added:** `POST /device/settings/change`. `/device/config` and `/device/config/project` return 410. |
|
||||
| `sfm/static/device_routing.js`, `sfm/static/sfm_webapp.js`, `sfm/sfm_webapp.html` | The edit form. |
|
||||
| `tests/device_access_fakes.py` | The fakes gain settings blocks, a schedule, and writes. |
|
||||
|
||||
---
|
||||
|
||||
### Task 1: Series 3 — assemble a settings read into the logical block
|
||||
|
||||
**Measured basis (spec, 2026-11-03):** unescape each `1A` data frame and take `data[11:]`. Every frame but the last starts with one non-content `00` byte; drop it. The result is 2,090 bytes with `N = 2090` at `[0:2]`.
|
||||
|
||||
**Files:**
|
||||
- Modify: `minimateplus/protocol.py`, near `read_compliance_config` (≈ line 913)
|
||||
- Modify: `minimateplus/client.py`
|
||||
- Modify: `docs/instantel_protocol_reference.md` (one dated row, 2026-11-03)
|
||||
- Test: `tests/test_s3_settings_read.py` (new)
|
||||
|
||||
**Interfaces:**
|
||||
- Produces:
|
||||
- `assemble_compliance_content(frames: list[bytes]) -> bytes`. `frames` is each data reply's `frame.data`, escapes kept, in order.
|
||||
- `is_compliance_content(block: bytes) -> bool`: `len == 2090` and `int.from_bytes(block[0:2], "big") == 2090`.
|
||||
- `COMPLIANCE_CONTENT_LEN = 2090`.
|
||||
- `MiniMateProtocol.read_compliance_content() -> bytes`:
|
||||
- sends the same probe and B/C/D requests as `read_compliance_config`;
|
||||
- a missing data frame raises `ProtocolError` (no `continue`);
|
||||
- returns the assembled bytes **without** judging them, so a monitoring unit's device-info answer comes back for the caller to recognise.
|
||||
- `MiniMateClient.read_compliance_content() -> bytes`.
|
||||
- `MiniMateClient.read_settings_blocks() -> dict` with keys `event_index`, `compliance`, `trigger` and `waveform`. Each value is the bytes its existing read returns:
|
||||
- `event_index`: `proto.read_event_index()`
|
||||
- `compliance`: `read_compliance_content()`
|
||||
- `trigger`: `proto.read_trigger_config()`
|
||||
- `waveform`: `proto.read_waveform_data_raw()`
|
||||
|
||||
- [ ] **Step 1: Write the failing tests** in `tests/test_s3_settings_read.py`. Use `tests/fixtures/minimate-bench-10-26-26-histogram` (`unit_replies.bin` parsed with `S3FrameParser`). Group the `0xE5` frames into reads: a frame with `len(data) == 11` starts each read. Take the write images from `tests/test_minimate_write_frames.py` (`WRITES[0:13]`, `WRITES[13:26]`; the `0x71` payloads `[16:]` joined).
|
||||
|
||||
```python
|
||||
def test_reads_assemble_to_2090_bytes(): # all 12 reads, both frame patterns (5 and 3 frames)
|
||||
assert all(len(assemble_compliance_content(r)) == 2090 for r in READS)
|
||||
|
||||
def test_a_read_after_a_blastware_write_equals_the_write():
|
||||
assert assemble_compliance_content(READS[1]) == IMAGES[0][:2090]
|
||||
assert assemble_compliance_content(READS[2]) == IMAGES[1][:2090]
|
||||
|
||||
def test_a_monitoring_units_answer_is_not_settings(): # READS[3:8] start 0e 'BE9441'
|
||||
assert [is_compliance_content(assemble_compliance_content(r)) for r in READS[3:8]] == [False] * 5
|
||||
assert all(is_compliance_content(assemble_compliance_content(r)) for r in READS[:3] + READS[8:])
|
||||
|
||||
def test_read_compliance_content_refuses_a_missing_frame():
|
||||
... # a fake transport that answers the probe and frame B, then times out: ProtocolError, nothing assembled
|
||||
```
|
||||
|
||||
- [ ] **Step 2: Run them.** `…pytest tests/test_s3_settings_read.py -q`. Expected: FAIL (ImportError: `assemble_compliance_content`).
|
||||
- [ ] **Step 3: Implement** the Produces block in `protocol.py` and `client.py`. Use `unescape_reply` from `minimateplus.framing`. The docstring cites the measurement and its fixture.
|
||||
- [ ] **Step 4: Run them.** Expected: PASS (4 passed).
|
||||
- [ ] **Step 5: Add a reference row** to `docs/instantel_protocol_reference.md` (Edit tool; CRLF), dated 2026-11-03, measured. Cover:
|
||||
- the assembly rule;
|
||||
- the round trip (2 of 2);
|
||||
- `[26:28]`: Blastware writes `00 00` (11 of 11), and the unit sets `01 7f` after monitoring;
|
||||
- the trailing two bytes: a per-unit Blastware constant (`7c ea` BE11529 ×9, `0c e9` BE9441 ×2), not the CRC, and never in a reply;
|
||||
- `0x09 [200:202]`: echoed 9 of 9 in April; changed on 10-26 (`17 17` → `78 76`).
|
||||
- [ ] **Step 6: Run the full suite** and compare the failure list with the baseline. **Then commit** (separate call): `feat(s3): assemble a settings read into the 2,090-byte block`.
|
||||
|
||||
---
|
||||
|
||||
### Task 2: The shared settings codec
|
||||
|
||||
**Files:**
|
||||
- Create: `micromate/setup_fields.py`
|
||||
- Modify: `micromate/setup_block.py`: add `with_crc(content: bytes) -> bytes`, which returns the content with `CRC-16/AUG-CCITT` over `[0:N-2]` written BE at `[N:N+2]`.
|
||||
- Test: `tests/test_setup_fields.py` (new)
|
||||
|
||||
**Interfaces:**
|
||||
- Consumes: Task 1's `assemble_compliance_content`, used in tests only. The codec itself imports nothing from `minimateplus` and nothing from `sfm`.
|
||||
- Produces (all pure). Each `content` is the 2,090-byte (Series 3) or 2,092-byte (Series 4) block.
|
||||
- `editable_fields(content: bytes, series: int) -> list[dict]`. Each dict has `field`, `label`, `kind` (`"number"`, `"choice"`, `"text"` or `"bool"`) and `value`, plus as relevant `unit`, `min`, `max`, `choices` (a list of `{value, label}`) and `maxlength`.
|
||||
- `field_values(content: bytes, series: int) -> dict[str, Any]`: the same fields, values only.
|
||||
- `check_changes(content: bytes, series: int, changes: dict) -> dict`: returns the normalised changes, or raises `SettingsValueError(ValueError)` with a plain sentence. It has two kinds of check: static (names, types, choices, spans) and content-dependent (unit strings, the trigger against the range).
|
||||
- `encode_setup(content: bytes, series: int, changes: dict) -> bytes`:
|
||||
- same length as `content`;
|
||||
- only the changed fields' bytes move;
|
||||
- bit fields are patched bit by bit;
|
||||
- Series 3 also sets `[26:28] = 00 00` (`S3_BLASTWARE_FIXED`);
|
||||
- Series 4 returns `with_crc(...)`.
|
||||
- `settings_state(before: bytes, written: bytes, now: bytes, *, series: int) -> str`. It compares `[0:2090]`:
|
||||
- `"as asked"` if `now` equals `written` (Series 4 also needs `crc_ok(now)`);
|
||||
- else `"unchanged"` if `now` equals `before`;
|
||||
- else `"differs"`.
|
||||
- `revision(blocks: list[bytes]) -> str` = `hashlib.sha256(b"".join(blocks)).hexdigest()[:16]`.
|
||||
- `S3_ALARM_WRITE_MEASURED = False`. While False, `geo_alarm_ips` is shown (read-only, `kind` plus `"readonly": True`) and refused in `check_changes`.
|
||||
|
||||
**The field registry** (content offsets; channel `k` = `1708 + 48·k`, `k` = 0, 1, 2 for the geophones):
|
||||
|
||||
| field | series | bytes | values (exact) |
|
||||
|---|---|---|---|
|
||||
| `record_mode` | 3 | `[5]` | `single_shot`=0, `continuous`=1, `histogram`=3, `histogram_continuous`=4 |
|
||||
| `record_mode` | 4 | `[5]` | `waveform`=1, `manual`=2, `histogram`=3, `combo`=4 |
|
||||
| `sample_rate` | 3, 4 | `[6:8]` u16 BE | {1024, 2048, 4096} |
|
||||
| `histogram_interval_s` | 3, 4 | `[8:10]` u16 BE | {2, 5, 15, 60, 300, 900} |
|
||||
| `record_time_s` | 3, 4 | `[18:22]` f32 BE | 1.0 ≤ v ≤ 20.0 |
|
||||
| `geo_trigger_ips` | 3, 4 | ch k `+30` f32 BE, all three | 0.005 ≤ v ≤ 0.6, and ≤ the (new) range's full scale (10.0 / 1.25) |
|
||||
| `geo_range` | 3 | ch k `+29` u8, all three | `normal`=0, `sensitive`=1 |
|
||||
| `geo_alarm_ips` | 3 (gated) | ch k `+38` f32 BE, all three | 0.005 ≤ v ≤ full scale |
|
||||
| `job_number` | 3, 4 | `[40:42]` u16 BE | 0 ≤ v ≤ 65535 |
|
||||
| `job_number_shown` | 3, 4 | `[39]` bit `0x02` | bool |
|
||||
| `note_1` … `note_4` | 3, 4 | value `[144+64n : 186+64n]`; label `[122+64n : 144+64n]` read only | printable ASCII 0x20–0x7E, ≤ 41 bytes, zero-filled to 42 |
|
||||
|
||||
Where the spans come from, recorded in the module as comments:
|
||||
- **Trigger and record time:** 75,958 Blastware reports, 2016–2026, scanned 2026-11-03. 7,586 print a trigger: 0.005–0.500 in/s, 20 values, all in/s. 7,631 print a record time: 1.0–10.0 s.
|
||||
- **The tops of the spans:** BE11529's 2026-04-20 writes and the UM20147 fixtures (trigger 0.6, record time 11), and BE9441's 10-26 setup (record time 20).
|
||||
- **Job number:** bounded by its encoding (UM20147 keypad 0 → 1 → 1234). The read-back verifies it.
|
||||
|
||||
**A level write is refused** unless all three geophone channels' unit string, `ch +34:+38` with NULs and `.` stripped, equals `in`. Measured: `in.` and `in` both occur on UM20147. A unit set to Metric is unmeasured.
|
||||
|
||||
- [ ] **Step 1: Write the failing tests** in `tests/test_setup_fields.py`:
|
||||
|
||||
```python
|
||||
def test_s3_reproduces_every_blastware_write():
|
||||
# BE11529's 9 April images (bridges/captures/4-20-26/**/raw_bw_*.bin), in time order (the HHMMSS in
|
||||
# the name): before = the previous image; the first (151921) uses the assembled 1A read in its own
|
||||
# raw_s3 capture if that read is whole, else it is skipped (say so in the test). BE9441's 2 images:
|
||||
# before = the assembled READS[0], then image 1. changes = field_values(after) for every field whose
|
||||
# value differs. Assert encode_setup(before, 3, changes)[:2090] == after[:2090].
|
||||
# The 16:26 write also moves [25] (mic on): include `_sensors_mic` as a test-only patch helper,
|
||||
# not a registry field.
|
||||
|
||||
def test_s4_fixture_pairs_reproduce():
|
||||
# for every ordered pair (a, b) of tests/fixtures/micromate-setup/*.bin whose differing bytes outside
|
||||
# [2090:2092] all lie inside registry fields: encode_setup(a, 4, {f: field_values(b)[f] for differing f}) == b
|
||||
|
||||
def test_trigger_checked_against_the_new_range(): ... # Series 3: {"geo_range": "sensitive", "geo_trigger_ips": 0.6} passes; a fake full scale below 0.6 refuses
|
||||
def test_spans_refuse_outside_values(): ... # 0.004 and 0.61 in/s; 0.9 and 20.1 s; sample rate 8192; interval 30
|
||||
def test_field_not_offered_for_the_series(): ... # geo_range on series 4 -> SettingsValueError naming the series
|
||||
def test_alarm_is_read_only_until_measured(): ... # Series 3 geo_alarm_ips -> SettingsValueError while S3_ALARM_WRITE_MEASURED is False
|
||||
def test_metric_unit_string_refuses_level_writes(): ... # ch +34 = b"mm\x00\x00" -> SettingsValueError; b"in.\x00" and b"in\x00\x00" pass
|
||||
def test_note_edges(): ... # "" clears; 41 bytes ok; 42 refused; "café" refused
|
||||
def test_note_labels_are_never_written(): ... # changing note_2 moves only [208:250]
|
||||
def test_bit_fields_keep_unknown_bits(): ... # [39] = 0x81: job_number_shown True -> 0x83, False -> 0x81
|
||||
def test_s3_fixed_bytes(): ... # any S3 encode sets [26:28] = 00 00
|
||||
def test_s4_encode_recomputes_the_crc(): ... # crc_ok(encode_setup(fixture, 4, {"job_number": 7}))
|
||||
def test_f32_values_read_back_as_asked(): ... # written = encode(0.3); settings_state(before, written, written) == "as asked"
|
||||
def test_settings_state(): ... # "as asked" / "unchanged" / "differs"; S4 with a bad CRC -> "differs"
|
||||
def test_revision_is_stable_and_content_sensitive(): ...
|
||||
```
|
||||
|
||||
- [ ] **Step 2: Run them.** Expected: FAIL (ModuleNotFoundError: `micromate.setup_fields`).
|
||||
- [ ] **Step 3: Implement** `micromate/setup_fields.py` and `with_crc`. Decode via the registry (not via `decode_setup`, whose notes are keyed by label). Note labels come from the unit and are display only.
|
||||
- [ ] **Step 4: Run them.** Expected: PASS. Then mutation-check `S3_BLASTWARE_FIXED` (remove it: the Blastware-write test fails), delete the `.pyc`, and restore.
|
||||
- [ ] **Step 5: Run the full suite** and compare with the baseline. **Commit:** `feat(codec): one settings codec for both series, on the shared layout`.
|
||||
|
||||
---
|
||||
|
||||
### Task 3: Micromate — read the schedule file
|
||||
|
||||
**Measured basis:** reference *The scheduler, and a generic file transfer* and *The schedule record format*.
|
||||
- `0x94 <path>` opens a file for read; `offset` = the path's length, and the payload is the path, unpadded.
|
||||
- `0x48` reads the next page, repeated until an all-zero 11-byte response.
|
||||
- The file is 260-byte records. `[4]` is the half-hour slot. `[6]` is the action bitmask: 2 start-with-setup, 4 stop, 8 self-check, 16 ACH. `[7]` is the name length; `[8:260]` is the name.
|
||||
|
||||
**Files:**
|
||||
- Create: `micromate/schedule.py`
|
||||
- Modify: `micromate/protocol.py` (`read_file`), `micromate/client.py`
|
||||
- Modify: `docs/micromate_protocol_reference.md`: one line under the scheduler section saying SFM reads it (read-only) from 2026-11-03.
|
||||
- Test: `tests/test_micromate_schedule.py` (new)
|
||||
|
||||
**Interfaces:**
|
||||
- Produces:
|
||||
- `SCHEDULE_PATH = "\\system\\schedule\\schedule.dat"`.
|
||||
- `MicromateProtocol.read_file(path: str) -> bytes`: the concatenated content of each `0x48` page after the page-0 descriptor, stopping at the all-zero response; at most 64 pages, else `ProtocolError`.
|
||||
- `MicromateClient.read_schedule() -> bytes`.
|
||||
- `MicromateClient.get_active_setup_raw() -> str`: the `0x41` name up to its NUL, **not** stripped.
|
||||
- `MicromateClient.get_prefs_content() -> bytes` (`0x08`), `get_trigger_content() -> bytes` (`0x2E`) and `get_setup_content() -> bytes` (`0x1A`), each `_content(...)` of its read.
|
||||
- `@dataclass(frozen=True) class ScheduleEntry`: `index: int`, `time: str` (`"HH:MM"`), `day: int`, `action_bits: int`, `actions: tuple[str, ...]`, `setup: str`.
|
||||
- `parse_schedule(body: bytes) -> list[ScheduleEntry]`: 260-byte records; a record with `[4:8]` all zero and no name ends the list. `actions` names the bits 2/4/8/16 as `start_with_setup`, `stop`, `self_check` and `call_home`; any other bit becomes `unknown(0xNN)`.
|
||||
- `schedule_conflicts(entries, active_setup: str) -> list[ScheduleEntry]`: start entries whose setup, compared case-insensitively after `strip()`, is not the active setup.
|
||||
|
||||
- [ ] **Step 1: Write the failing tests.** Parse the bodies from `bridges/captures/9-24-26 - micromate2/raw_s3_20260924_191835_read_scheduler.bin` (frames 0–4), and from the two `raw_*_20260925_*` captures, with `MicromateFrameParser`.
|
||||
|
||||
```python
|
||||
def test_the_read_capture_parses(): # 2 records: start-with-setup 07:30 (40-char name), call_home 19:30 (no name)
|
||||
def test_the_five_entry_schedule_parses(): # 07:30 start TEST1.mmb, 08:00 stop, 08:30 self_check, 09:00 start test2.mmb, 19:30 call_home
|
||||
def test_conflicts_are_case_insensitive(): # active "test1.MMB" -> only the test2.mmb start conflicts
|
||||
def test_no_schedule_records_is_no_conflict(): assert schedule_conflicts(parse_schedule(bytes(524)), "x.mmb") == []
|
||||
def test_read_file_sends_the_path_unpadded_and_stops_at_zeros(): ... # a fake protocol: 0x94 offset 0x001D, then 0x48 until all-zero
|
||||
def test_get_active_setup_raw_keeps_spaces(): ... # " LOC 4 .mmb " survives
|
||||
```
|
||||
|
||||
- [ ] **Step 2: Run them.** Expected: FAIL (ModuleNotFoundError: `micromate.schedule`).
|
||||
- [ ] **Step 3: Implement** the Produces block. `read_file` builds `0x94` with `build_request(0x94, len(path), bytes(10), path.encode("ascii"))`. Both SUBs are already in `READ_SUBS`.
|
||||
- [ ] **Step 4: Run them.** Expected: PASS.
|
||||
- [ ] **Step 5: Run the full suite** and compare with the baseline. **Commit:** `feat(micromate): read the schedule file (read-only)`.
|
||||
|
||||
---
|
||||
|
||||
### Task 4: Change-path pieces and the Series 4 settings change
|
||||
|
||||
**Files:**
|
||||
- Modify: `sfm/device_access/errors.py`, `sfm/device_access/change.py`, `micromate/opcodes.py`, `sfm/device_access/s4.py`, `tests/device_access_fakes.py`
|
||||
- Modify: `tests/test_micromate_execute.py`, `tests/test_micromate_opcodes.py`. Their over-ceiling example `0x71` becomes enableable here; use `0xA8` (delete one event) instead.
|
||||
- Test: `tests/test_device_access_s4_settings.py` (new)
|
||||
|
||||
**Interfaces:**
|
||||
- Consumes:
|
||||
- Task 2: `editable_fields`, `field_values`, `check_changes`, `encode_setup`, `settings_state`, `revision`.
|
||||
- Task 3: `read_schedule`, `parse_schedule`, `schedule_conflicts`, `get_active_setup_raw`, and the content getters.
|
||||
- `micromate.writes.plan_setup_push(prefs, trigger, setup, name)`.
|
||||
- Produces:
|
||||
- `class SettingsChanged(DeviceError)`, `http_status = 409`.
|
||||
- `class ChangeRefused(DeviceError)`, `http_status = 409`.
|
||||
- `settings_change() -> ChangeKind("change settings", "as asked", "applied")`.
|
||||
- `ENABLEABLE_WRITES = frozenset({0x96, 0x97, 0x7E, 0x7F, 0xDA, 0x68, 0x73, 0x82, 0x83, 0x71, 0x72})`.
|
||||
- `s4_settings(client, serial) -> UnitSettings`. It keeps every current field, plus `detail["editable"] = editable_fields(setup, 4)`. The revision comes only from a preview (dry run), never from this read.
|
||||
- `s4_change_settings(client, serial, *, changes: dict, revision: Optional[str], dry_run: bool, audit, address, caller, sleep, verify_timeout_s, verify_interval_s) -> ChangeResult`.
|
||||
|
||||
**`s4_change_settings` behaviour**, through `run_change` (`even_if_already=False`):
|
||||
|
||||
- **`read_state`, first call:**
|
||||
- Read the run state.
|
||||
- `calling_home` and `unknown*` are returned as they are.
|
||||
- `monitoring` raises `UnitStateUnknown(f"{serial} is monitoring -- stop it first (a stop makes it call in if call-home is on) -- nothing sent")`.
|
||||
- Read the name (raw), prefs, trigger and setup.
|
||||
- `check_changes` (a `SettingsValueError` becomes `BadRequest`).
|
||||
- When live, `revision([name.encode("ascii"), prefs, trigger, setup])` must equal the request's. Otherwise raise `SettingsChanged("the unit's settings changed since the preview -- preview again; nothing sent")`.
|
||||
- `image = encode_setup(setup, 4, changes)`.
|
||||
- Read the schedule; a read error is kept as a blocking reason.
|
||||
- Return `settings_state(setup, image, setup, series=4)`.
|
||||
- **Later calls:** read the setup and return `settings_state(before, image, now, series=4)`.
|
||||
- **`describe_plan`:**
|
||||
- `plan_setup_push(prefs, trigger, image, name).describe()`, plus `fields` = `{f: {label, old, new}}` for the changed fields, `revision`, `warnings` and `blocked`.
|
||||
- `warnings` always includes: "this reads the unit's keypad edit buffer: if someone is in its menu, their unsaved edits are sent too".
|
||||
- `blocked`:
|
||||
- the name is `factory.MMB` (case-insensitive): "this unit is running its factory setup; load any other setup on its keypad, then try again";
|
||||
- each schedule conflict: "this unit's schedule loads <setup> at <HH:MM>, which would replace this change";
|
||||
- a schedule read error: "could not read this unit's schedule (<error>) -- SFM will not change a unit whose schedule it cannot check";
|
||||
- `plan_setup_push` raising `ValueError` (a block size or header THOR's offsets were never seen at, or a failed checksum): "this unit's <message> -- SFM has not seen a block like it".
|
||||
- When `blocked` is non-empty, `steps` is `[]`, and a live call raises `ChangeRefused("; ".join(blocked) + " -- nothing sent")`.
|
||||
- When the schedule names the active setup, `warnings` adds: "the unit's schedule loads this setup at <HH:MM>; the change survives it".
|
||||
- **`send`:** `client.protocol.execute(plan)`, as `s4_change_call_home` does.
|
||||
- **`snapshot`:**
|
||||
- `fields`: `{f: {label, old, new, now}}`;
|
||||
- `before` / `after` hex of the setup;
|
||||
- `changed_offsets`;
|
||||
- `prefs` and `trigger`: before hex only.
|
||||
- **`is_refusal`**, **`is_ring`** and **`pre_send`**: as in `s4_change_call_home`.
|
||||
|
||||
**Validation order:** a live call without `revision` is refused before any I/O, in Task 6's `DeviceAccess` (not here).
|
||||
|
||||
- [ ] **Step 1: Write the failing tests.** Extend `FakeMicromateClient` with:
|
||||
- `setup` (default: `tests/fixtures/micromate-setup/um20147_baseline.bin`'s last 2,092 bytes);
|
||||
- `prefs`, `trigger` and `active_name` (default `"test2.mmb"`);
|
||||
- `schedule_body` (default `bytes(524)`) and `schedule_error`;
|
||||
- `execute` applies a setup-push plan's `0x71` data to `self.setup` (re-adding the CRC with `with_crc`), so a read-back sees it.
|
||||
|
||||
```python
|
||||
def test_s4_dry_run_previews_old_to_new_and_sends_nothing(): # fields == {"geo_trigger_ips": {"label": ..., "old": 0.5, "new": 0.3}}; revision present; fake.executed == []
|
||||
def test_s4_trigger_change_sends_the_push_and_verifies(): # subs [0xDA,0x68,0x73,0x82,0x83,0x71,0x72]; outcome sent/ok; state_after "as asked"
|
||||
def test_s4_stale_revision_sends_nothing(): # SettingsChanged; fake.executed == []; audit has no rows
|
||||
def test_s4_already_as_asked_is_skipped(): # outcome skipped, nothing executed
|
||||
def test_s4_monitoring_is_refused(dry_run in (True, False)): # "stop it first" and "nothing sent"
|
||||
def test_s4_factory_setup_is_refused_live_and_shown_in_preview():
|
||||
def test_s4_schedule_conflict_blocks(): # schedule starts "other.mmb" at 07:00 -> ChangeRefused naming other.mmb and 07:00
|
||||
def test_s4_schedule_on_the_active_setup_warns_only():
|
||||
def test_an_unreadable_schedule_refuses():
|
||||
def test_no_schedule_records_is_no_conflict(): # bytes(524) -> sent
|
||||
def test_s4_a_lost_ack_records_what_the_unit_holds(): # execute_error -> outcome failed, sent True, snapshot present
|
||||
def test_s4_unseen_block_size_is_blocked(): # prefs 91 B -> preview blocked; live ChangeRefused; nothing executed
|
||||
def test_setup_push_subs_are_now_enableable():
|
||||
```
|
||||
|
||||
- [ ] **Step 2: Run them.** Expected: FAIL (ImportError: `s4_change_settings`).
|
||||
- [ ] **Step 3: Implement** the Produces block and update `s4_settings`. In the two opcode tests, swap the over-ceiling example to `0xA8`.
|
||||
- [ ] **Step 4: Run them**, plus `tests/test_micromate_execute.py`, `tests/test_micromate_opcodes.py`, `tests/test_micromate_writes.py` (THOR's setup-push frames still reproduce) and `tests/test_device_access_s4_call_home.py`. Expected: PASS.
|
||||
- [ ] **Step 5: Run the full suite** and compare with the baseline. **Commit:** `feat(s4): change a Micromate's settings by serial, audited, schedule-checked`.
|
||||
|
||||
---
|
||||
|
||||
### Task 5: The Series 3 settings change
|
||||
|
||||
**Files:**
|
||||
- Modify: `sfm/device_access/s3.py`, `minimateplus/client.py` (`push_config_raw` pre-check), `tests/device_access_fakes.py`
|
||||
- Test: `tests/test_device_access_s3_settings.py` (new)
|
||||
|
||||
**Interfaces:**
|
||||
- Consumes:
|
||||
- Task 1: `read_compliance_content`, `read_settings_blocks`, `is_compliance_content`.
|
||||
- Task 2: the codec.
|
||||
- Task 4: `settings_change`, `SettingsChanged`, `ChangeRefused`.
|
||||
- `MiniMateClient.push_config_raw(event_index, compliance, trigger, waveform)`.
|
||||
- Produces:
|
||||
- `push_config_raw` raises `ImageRefused` (from `minimateplus.protocol`) when its pre-check refuses a block, before any frame.
|
||||
- `Series3Adapter.settings(address, serial) -> UnitSettings`. It is built on `read_compliance_content` and the codec, with the same top-level fields as today, plus `detail["editable"]`. A non-settings answer raises `UnitStateUnknown(S3_SETTINGS_WHILE_MONITORING)`.
|
||||
- `S3_SETTINGS_WHILE_MONITORING = "did not return its settings -- a MiniMate answers this way while monitoring; stop monitoring first"`.
|
||||
- `Series3Adapter.change_settings(address, serial, *, changes, revision, dry_run, audit, caller, sleep, verify_timeout_s, verify_interval_s) -> ChangeResult`, through `run_change` and `self._run(address, op, retry=False)`:
|
||||
- `read_serial`: `client.connect().serial`.
|
||||
- **`read_state`, first call:**
|
||||
- Wake, then `read_settings_blocks()`.
|
||||
- A non-settings `compliance` raises `UnitStateUnknown(f"{serial} {S3_SETTINGS_WHILE_MONITORING} -- nothing sent")`.
|
||||
- `check_changes`, and the live revision check over `[event_index, compliance, trigger, waveform]`.
|
||||
- Compute `image = encode_setup(...)` and return `settings_state(...)`.
|
||||
- **Later calls:** wake, `read_compliance_content()`, then the verdict.
|
||||
- **`describe_plan`:**
|
||||
- `steps` in Blastware's order: 68 (event index, as read), 73, 71 (settings block, 2,092 B), 72, 82 (trigger, as read), 83, 69 (waveform data, as read), 74, 72. Each step has `sub`, `what` and `data_len`.
|
||||
- `fields`, `revision` and `warnings` as Series 4. The warning: "the two bytes after the settings block go out as 00 00 (Blastware sends its own constant; effect unmeasured)".
|
||||
- **`send`:** `client.push_config_raw(event_index, image, trigger, waveform)`.
|
||||
- **`is_refusal`:** `isinstance(e, ImageRefused)`.
|
||||
- **`snapshot`:** as Series 4, without prefs and trigger.
|
||||
|
||||
- [ ] **Step 1: Write the failing tests.** Extend `FakeMiniMateClient` with:
|
||||
- `settings_blocks`: the default compliance is BE9441's assembled 10-26 read 2; `event_index`, `trigger` and `waveform` are the `0x68`, `0x82` and `0x69` payloads (`[16:]`) of `WRITES[13:26]` in `tests/test_minimate_write_frames.py`, each minus its two trailing bytes (a write is the read plus two);
|
||||
- `push_config_raw` records its four arguments and makes the compliance the new `read_compliance_content`;
|
||||
- `monitoring_settings=True` returns a device-info-shaped block.
|
||||
|
||||
```python
|
||||
def test_s3_settings_read_uses_the_codec(): # editable includes geo_range; record_mode "histogram"; notes by slot with unit labels
|
||||
def test_s3_dry_run_previews_and_sends_nothing():
|
||||
def test_s3_trigger_change_sends_the_units_own_blocks(): # push args: event_index/trigger/waveform == the read blocks; compliance == encode_setup(...)
|
||||
def test_s3_change_verifies_by_read_back(): # outcome sent/ok, state_after "as asked", snapshot fields old/new/now
|
||||
def test_s3_stale_revision_sends_nothing():
|
||||
def test_s3_monitoring_is_refused(dry_run in (True, False)):
|
||||
def test_s3_a_refused_image_is_audited_as_nothing_sent(): # push_config_raw raises ImageRefused -> row sent 0, "refused before sending"
|
||||
def test_push_config_raw_precheck_raises_image_refused(): # a 2,089-byte compliance block -> ImageRefused, no frame written
|
||||
```
|
||||
|
||||
- [ ] **Step 2: Run them.** Expected: FAIL (AttributeError: `change_settings`).
|
||||
- [ ] **Step 3: Implement** the Produces block.
|
||||
- [ ] **Step 4: Run them**, plus `tests/test_s3_call_home.py`, `tests/test_minimate_write_frames.py` and `tests/test_device_access_*`. Expected: PASS, except the tests Task 6 deletes or rewrites. If one fails here only because it pins `apply_config`, leave it for Task 6 and note that in the ledger.
|
||||
- [ ] **Step 5: Run the full suite** and compare with the baseline. **Commit:** `feat(s3): change a MiniMate's settings by serial on the shared codec`.
|
||||
|
||||
---
|
||||
|
||||
### Task 6: Device access, the route, and retiring the legacy write
|
||||
|
||||
**Files:**
|
||||
- Modify: `sfm/device_access/access.py`, `sfm/server.py`, `minimateplus/client.py`
|
||||
- Delete: `poc_set_project.py`. Remove `exp_compliance_only` (and its registration) from `experiments.py`.
|
||||
- **Ruling (spec: "the legacy write is retired"):** both write a live unit through the retired encoder, which #46 found wrong. Git keeps them.
|
||||
- Modify tests:
|
||||
- `tests/test_s3_compliance_anchor_fields.py`: remove its write-side tests (the encoder is gone).
|
||||
- `tests/test_minimate_write_frames.py`: `test_apply_config_writes_the_units_own_trigger_block` moves to Task 5's `test_s3_trigger_change_sends_the_units_own_blocks`; delete it here.
|
||||
- `tests/test_server_series3_guard.py`: drop `apply_config` from `WRITES` and its fake method.
|
||||
- `tests/test_server_device_access.py`: `/device/config` now 410.
|
||||
- Test: `tests/test_device_access_settings.py` (new), `tests/test_server_settings_change.py` (new)
|
||||
|
||||
**Interfaces:**
|
||||
- Consumes: Task 4's `s4_change_settings` and Task 5's `Series3Adapter.change_settings`.
|
||||
- Produces:
|
||||
- `DeviceAccess.change_settings(address, serial, *, changes: dict, revision: Optional[str], dry_run: bool = False, caller: str = "api") -> ChangeResult`:
|
||||
- `normalise_serial`, then `series_for_serial`;
|
||||
- `changes` must be a non-empty dict, else `BadRequest`;
|
||||
- a live call without `revision` raises `BadRequest("preview first: a live change needs the revision from its preview -- nothing sent")`;
|
||||
- a live call with no audit log raises `NotSupported` (as `set_call_home`);
|
||||
- `_dispatch(..., change=True)` with `verify_timeout_s=_SETTINGS_VERIFY_TIMEOUT_S = 2.0` and `verify_interval_s=_SETTINGS_VERIFY_INTERVAL_S = 1.0`.
|
||||
- `POST /device/settings/change`:
|
||||
- query: `serial` (required), `host`, `tcp_port`, `port`, `baud`, `dry_run`, `caller`;
|
||||
- JSON body `{"changes": {...}, "revision": "..."}`;
|
||||
- returns `_change_response(...)`;
|
||||
- added to `_SERIAL_AWARE_PATHS`.
|
||||
- `POST /device/config` and `POST /device/config/project` return **410** with `{"detail": "retired: change a unit's settings by serial with POST /device/settings/change (audited, previewed, read back)"}`. Remove the cache-dirty hooks that only these routes called; keep the read routes.
|
||||
- Delete `MiniMateClient.apply_config`, `set_project_info` and `_encode_compliance_config`, and any import left orphaned.
|
||||
|
||||
- [ ] **Step 1: Write the failing tests:**
|
||||
|
||||
```python
|
||||
def test_live_change_without_revision_is_refused_before_io(): # factory never called
|
||||
def test_empty_changes_is_a_bad_request():
|
||||
def test_change_settings_dispatches_by_series_with_change_true():
|
||||
def test_route_dry_run_returns_fields_and_revision(): # 200, body.plan.fields, body.plan.revision
|
||||
def test_route_verified_change_is_200_and_mismatch_409():
|
||||
def test_route_unconfirmed_carries_sent_and_audit_id():
|
||||
def test_route_refusal_is_409_with_reason(): # ChangeRefused / SettingsChanged / monitoring
|
||||
def test_legacy_config_routes_are_gone(): # both 410, nothing reaches a client factory
|
||||
def test_settings_change_is_serial_aware(): # in _SERIAL_AWARE_PATHS; a UM serial goes to the Series-4 path
|
||||
```
|
||||
|
||||
- [ ] **Step 2: Run them.** Expected: FAIL (404 / AttributeError).
|
||||
- [ ] **Step 3: Implement** the Produces block, the deletions, and the test updates listed under Files.
|
||||
- [ ] **Step 4: Run them**, plus `tests/test_server_*.py`. Expected: PASS. Check that `grep -rn "apply_config\|set_project_info\|_encode_compliance_config" --include=*.py .` finds only comments and history.
|
||||
- [ ] **Step 5: Run the full suite** and compare with the baseline. **Commit:** `feat(sfm): POST /device/settings/change; retire the legacy config write`.
|
||||
|
||||
---
|
||||
|
||||
### Task 7: The page — edit, preview, send, "the unit now holds"
|
||||
|
||||
**Files:**
|
||||
- Modify: `sfm/static/device_routing.js`, `sfm/static/sfm_webapp.js`, `sfm/sfm_webapp.html`
|
||||
- Modify: `CLAUDE.md` (the "Where things stand" Series-4 parity line: phase 5 built, bench pending), and the spec's status line ("Built 2026-11-xx; bench pending").
|
||||
- Test: `tests/test_webapp_device_routing.py` (extend `EXPORTS` and cases), `tests/test_webapp_static.py`
|
||||
|
||||
**Interfaces:**
|
||||
- Consumes: `UnitSettings.detail.editable` / `.revision`, and the `ChangeResult` shapes from Tasks 4–6.
|
||||
- Produces (DOM-free, in `device_routing.js`):
|
||||
- `DEVICE_ROUTES.settings_change = ['POST', '/device/settings/change', true]`; remove `config_write`.
|
||||
- `controlsFor(unit)`: `configWrite: serialMode && (series === 3 || series === 4)`; `reasons.configWrite: 'By serial only: Preview, then Send (audited).'`
|
||||
- `settingsFormFields(st) -> Array<{field, label, kind, value, unit?, min?, max?, choices?, maxlength?, readonly?}>`: from `st.detail.editable`, in that order.
|
||||
- `settingsChanges(fields, edited) -> object`: only fields whose edited value differs. Numbers compare as numbers; read-only fields are ignored.
|
||||
- `settingsPreviewRows(body) -> Array<[label, old, new]>`, from `body.plan.fields`.
|
||||
- `settingsBlockedText(body) -> string`: `body.plan.blocked` joined; `''` if none.
|
||||
- `settingsResultRows(body) -> Array<[label, old, new, now]>`, from `body.detail.snapshot.fields`.
|
||||
- **Page behaviour** (`sfm_webapp.js` glue; HTML ids `cfg-edit`, `cfg-preview-btn`, `cfg-send-btn`, `cfg-preview`, `cfg-result`):
|
||||
- The serial-mode Config pane heading reads **"On the unit <SERIAL> — read <HH:MM>"**.
|
||||
- The form is built from `settingsFormFields`.
|
||||
- **Preview** POSTs a dry run and shows old → new, warnings and blocked reasons. It keeps `revision` and enables **Send** only when nothing is blocked and something changes.
|
||||
- **Send** asks `confirm()` naming the serial and the fields, then POSTs live with the kept revision and shows "the unit now holds" rows. Errors go through `changeErrorText`.
|
||||
- Editing any field after a preview disables **Send** until the next preview.
|
||||
- The by-host legacy form loses its write button. Its read stays.
|
||||
- No inline script; listeners via `addEventListener`.
|
||||
|
||||
- [ ] **Step 1: Write the failing Node-run cases** in `tests/test_webapp_device_routing.py`:
|
||||
- `controlsFor` gives `configWrite` true by serial for both series, and false by host;
|
||||
- `settingsChanges` returns only differing fields and compares `0.30` with `0.3` as equal;
|
||||
- `settingsPreviewRows` / `settingsResultRows` / `settingsBlockedText` on bodies shaped as Task 6 returns them;
|
||||
- `deviceUrl('settings_change', unit)` → `/device/settings/change?serial=…`;
|
||||
- `config_write` is no longer a route.
|
||||
|
||||
In `tests/test_webapp_static.py`, assert the page has no inline `<script>` body and loads both static files.
|
||||
- [ ] **Step 2: Run them.** `…pytest tests/test_webapp_device_routing.py tests/test_webapp_static.py -q`. Expected: FAIL (`settingsChanges` is not a function).
|
||||
- [ ] **Step 3: Implement** the Produces block and the page behaviour.
|
||||
- [ ] **Step 4: Run them.** Expected: PASS. Then run the page under the jsdom harness pattern from phase 4 (`smoke/page_files_load.js` in the scratchpad): the page loads with no console error, and a stubbed dry-run body renders the preview rows.
|
||||
- [ ] **Step 5: Update `CLAUDE.md`** and the spec status line. **Run the full suite** and compare with the baseline. **Commit:** `feat(webapp): edit a unit's settings by serial: preview, send, read back`.
|
||||
|
||||
---
|
||||
|
||||
## After the build: final review, then the bench
|
||||
|
||||
The bench is not a task: it runs after the whole-branch review and its fixes, with Brian at the units, and **each send needs his explicit go**. Run SFM with `ringkit/sfm_parity.py` (port 8299; never 8200). Order:
|
||||
|
||||
1. **Read-only, both units:**
|
||||
- `GET /device/settings` by serial; Brian matches it against each unit's screen.
|
||||
- UM20147: `read_schedule` (measure what a unit with no schedule answers, and whether `0x08` shows the scheduler switch).
|
||||
2. **Dry runs** of a trigger change on each unit. Read the preview with Brian.
|
||||
3. **One field per unit**, with Brian's go:
|
||||
- the trigger (UM20147 0.5 → 0.3; BE9441 0.04 → 0.05);
|
||||
- read back; Brian checks the unit's menu;
|
||||
- change it back, with another go.
|
||||
4. **A notes change** on each (go).
|
||||
5. **A several-field "backup unit" change** on each (go).
|
||||
6. **Refusals:**
|
||||
- a dry run while monitoring (expect the refusal);
|
||||
- UM20147 with a schedule naming another setup, if Brian sets one up in THOR (expect the block).
|
||||
7. **Alarm level (Series 3):**
|
||||
- one write with Brian's go, read back and checked on BE9441's menu;
|
||||
- only then flip `S3_ALARM_WRITE_MEASURED`, in its own commit naming the bench result.
|
||||
|
||||
Record everything in the spec's bench section and both protocol references (measured), then the devlog.
|
||||
Reference in new issue
Block a user