Release v0.34.0 — Series-4 parity, and most of Blastware's report from the event file alone #59
@@ -540,6 +540,55 @@ matters to is named.
|
||||
through `0x94`/`0x48` may detect unsaved keypad edits, which would undercut
|
||||
"can't be detected from the wire". One bench check.
|
||||
|
||||
## Left open by the phase 3 review (2026-10-23)
|
||||
|
||||
The whole-phase review judged phase 3 ready for the bench, with nothing that
|
||||
sends twice, sends without an audit row, or sends to an unverified unit. These
|
||||
items were left for later on purpose:
|
||||
|
||||
- **Series-3 change path shape. Settle before the MiniMate bench check.**
|
||||
- The change path makes one POLL at a 120 s receive timeout, with no retry. A
|
||||
cold MiniMate that drops that POLL costs 120 s of a locked unit and then a
|
||||
504. The legacy route retried `poll()` on the same connection at 10 s.
|
||||
- The identity read is a full `connect()` (POLL, `0x15`, `0x01`, `0x1A`, `0x08`).
|
||||
The spec asks for one serial read.
|
||||
- Proposed: 10 s timeouts before the send, one identity-poll retry on the same
|
||||
connection (a read, never the write), POLL plus `0x15` in place of
|
||||
`connect()`, and the long timeout only on the read-back polls.
|
||||
- That needs two measurements first: whether a *monitoring* MiniMate answers
|
||||
the full `connect()` over TCP, and what `0x1C` reads during the ~40 s sensor
|
||||
check.
|
||||
- **For 1c (the webapp).**
|
||||
- 409 means three things. "Wrong unit" and "unmeasured state" sent nothing;
|
||||
"mismatch" sent a frame with a clean ack. Only the body tells them apart.
|
||||
- `ChangeResult.detail` is a dict, so the webapp's `e.detail || r.statusText`
|
||||
would print `[object Object]`.
|
||||
- The 60 s verify window, plus the call-up, plus up to 20 s of lock wait,
|
||||
exceeds the 60 s Terra-View proxy timeout. A mismatch could never be
|
||||
delivered through that proxy.
|
||||
- Nothing marks `pending` rows left by a restart mid-change. Reconcile them at
|
||||
server start only, never on every `SeismoDb` open.
|
||||
- **A late `0x69` after a lost ack.** When the ack is lost but the follow-up
|
||||
read validates, the line is kept, and a late `0x69` then breaks the next
|
||||
unrelated request with a 502. Safe, but confusing. Hanging up after any lost
|
||||
ack needs a way to release the line on a path that returns a result.
|
||||
- **Legacy routes take no per-address lock.** They can interleave with an
|
||||
audited change on the same address. This belongs with the blind-stop-tools
|
||||
decision, which is still open.
|
||||
- **Test and scan gaps.**
|
||||
- The `protocol.execute(` caller scan does not catch an aliased caller.
|
||||
- Dropping the S4 ack's `data` field is not caught by any test.
|
||||
- The fake's `fail` queue is also consumed by `read_unsolicited` on the change
|
||||
path.
|
||||
- **Docs nits.**
|
||||
- `s4.py` says `ChangeUnconfirmed` follows "a link fault or a ring". It also
|
||||
follows a `calling_home` read.
|
||||
- The 2026-10-02 CLAUDE.md bullet still says "Read-only".
|
||||
- The route docstrings' 409 line omits the held-line `WrongUnit`.
|
||||
- **For the merge to dev.** The changelog states: a new `device_commands` table
|
||||
(`CREATE TABLE IF NOT EXISTS`) plus a `_migrate` step that adds `sent` and
|
||||
`states` to tables created from this branch. Prod: no migration, no backfill.
|
||||
|
||||
## Table 2: to be added later (both series)
|
||||
|
||||
| area | item |
|
||||
|
||||
Reference in new issue