Release v0.34.0 — Series-4 parity, and most of Blastware's report from the event file alone #59

Merged
serversdown merged 245 commits from dev into main 2026-11-04 18:19:24 -05:00
Showing only changes of commit bbc6fe2a61 - Show all commits
@@ -133,8 +133,10 @@ the fields both series have under the same names and units: record mode,
sample rate, record time, histogram interval, trigger levels, the notes as
label → value. Model-specific fields go under `detail`.
**Existing Series-3 response shapes change to the shared models.** The webapp
is updated in the same phase; Terra-View does not call `/device/*`. The
**Requests that include `serial` get the shared models; requests without it
keep today's Series-3 shapes, unchanged.** Nothing breaks in between: the
webapp moves to `serial` in phase 1c, and the old path retires after that and
after `watch_unit.sh` moves. Terra-View does not call `/device/*`. The
emergency endpoints (`stop_monitoring_*`, `rescue`, `events/erase`) are not
touched and stay Series-3 only; a `UM` serial gets 501.
@@ -325,8 +327,10 @@ Each safety piece arrives with its first real use, so nothing sits untested.
1. **One contract, reads only.** `device_access.py`, the two adapters, the
shared models, series selection, the per-unit lock, the error mapping, and
sessions with ring safety. Rows 1–5 for **both** series through the same
endpoints. **No writes.**
- 1b. **The webapp:** serial + address, and the same read panels for both
endpoints. **No writes.** Split into three plans:
- 1a. The foundation plus identify / status / settings for both series.
- 1b. Event list and download for both series (rows 4–5).
- 1c. **The webapp:** serial + address, and the same read panels for both
series.
2. **Encoder + opcode guard + dry run + frame-reproduction tests.** Still
nothing sent.