Release v0.34.0 — Series-4 parity, and most of Blastware's report from the event file alone #59
@@ -740,6 +740,19 @@ items were left for later on purpose:
|
||||
|
||||
## Parking lot
|
||||
|
||||
- **Deleting events after a call-in is the call-in receiver's job, not 1c's**
|
||||
(Brian, 2026-10-29). In production Blastware ACH (Series 3) and THOR (Series
|
||||
4) download, then delete; SFM gets the files afterwards from the watchers. If
|
||||
SFM ever becomes the receiver, deletion comes with it:
|
||||
- the protocol is already mapped: erase-all `A3 → 1C → 06 → A2` (S3), and
|
||||
per-event `0xA8` + `0xAA` (S4);
|
||||
- "Monitor While Calling Home" silently blocks erase while reporting
|
||||
success, so the server-side high-water mark is load-bearing;
|
||||
- `0xA2` means CONFIRM ERASE on S3 and END CALL on S4.
|
||||
|
||||
1c touches only Diagnostics' S3 erase-all, which it gates to a confirmed
|
||||
Series-3 unit, server- and page-side.
|
||||
|
||||
- **Speed (Brian's goal: faster than Blastware), after 1c.** Measured on
|
||||
BE9441, 2026-10-27 23:41, serial cable:
|
||||
- wake + serial number take 0.16 s;
|
||||
|
||||
Reference in new issue
Block a user