Release v0.34.0 — Series-4 parity, and most of Blastware's report from the event file alone #59

Merged
serversdown merged 245 commits from dev into main 2026-11-04 18:19:24 -05:00
4 changed files with 102 additions and 12 deletions
Showing only changes of commit cdc6360ec0 - Show all commits

No files matched your search

+10 -7
View File
@@ -85,20 +85,23 @@ def run_change(*, serial: str, series: int, start: bool, dry_run: bool, even_if_
def states(seen: List[str], after: Optional[str]) -> Dict[str, Any]:
return {"before": before, "seen": list(seen), "after": after}
def finish(unit: str, **fields: Any) -> None:
def finish(unit: str, *, release_line: bool = False, **fields: Any) -> None:
"""The only way a row is finished. `unit` says what happened to the
unit, so a finish that fails still says it."""
unit, so a finish that fails still says it. `release_line` says whether
this path hangs up anyway, so a failed finish does not hold the line."""
try:
audit.finish(cid, **fields)
except Exception as exc: # noqa: BLE001
raise AuditIncomplete(
f"{unit} -- but audit record {cid} could not be finished: {exc}") from exc
f"{unit} -- but audit record {cid} could not be finished: {exc}",
release_line=release_line) from exc
def unconfirmed(unit: str, cause: BaseException, *, went_out: str, status: int,
**fields: Any) -> NoReturn:
"""Finish the row, then say the change went out (or may have) and name it.
`went_out` is "acknowledged" or "unknown"; the row's `sent` follows it."""
finish(unit, sent=SENT_ACKNOWLEDGED if went_out == "acknowledged" else SENT_UNKNOWN,
finish(unit, release_line=True,
sent=SENT_ACKNOWLEDGED if went_out == "acknowledged" else SENT_UNKNOWN,
**fields)
raise ChangeUnconfirmed(f"{unit} -- audit record {cid}", audit_id=cid, sent=went_out,
http_status=status) from cause
@@ -119,12 +122,12 @@ def run_change(*, serial: str, series: int, start: bool, dry_run: bool, even_if_
pre_send() # sends nothing: drains what is already waiting
except Exception as exc: # noqa: BLE001
if is_ring(exc):
finish("nothing was sent (a call-home began before sending)",
finish("nothing was sent (a call-home began before sending)", release_line=True,
outcome="failed", verified="not_checked", ack=None,
error="a call-home began before sending -- nothing sent",
sent=NOTHING_SENT, states=states([before], None))
raise CallHomeInProgress(CALL_HOME_MESSAGE) from exc
finish(f"nothing was sent (the line failed before sending: {exc})",
finish(f"nothing was sent (the line failed before sending: {exc})", release_line=True,
outcome="failed", verified="not_checked", ack=None,
error=f"the line failed before sending -- nothing sent: {exc}",
sent=NOTHING_SENT, states=states([before], None))
@@ -134,7 +137,7 @@ def run_change(*, serial: str, series: int, start: bool, dry_run: bool, even_if_
ack = send() # the only send; nothing below can reach it again
except Exception as exc: # noqa: BLE001 -- recorded, never retried
if is_refusal(exc): # refused by the gate: nothing went out
finish(f"nothing was sent (refused before sending: {exc})",
finish(f"nothing was sent (refused before sending: {exc})", release_line=True,
outcome="failed", verified="not_checked", ack=None,
error=f"refused before sending: {exc}",
sent=NOTHING_SENT, states=states([before], None))
+9 -1
View File
@@ -33,9 +33,17 @@ class AuditUnavailable(DeviceError):
class AuditIncomplete(DeviceError):
"""The unit was dealt with, but its audit row could not be finished. The
message says what happened to the unit first, then names the row."""
message says what happened to the unit first, then names the row.
`release_line` is True when the path would have hung up had the finish
worked (a ring, a link fault, a refusal): the failed write to the audit log
must not turn that into a held line, which would block a call-home."""
http_status = 500
def __init__(self, message: str, *, release_line: bool = False) -> None:
super().__init__(message)
self.release_line = release_line
class ChangeUnconfirmed(DeviceError):
"""A change failed after its frame went out, or may have gone out.
+12 -3
View File
@@ -23,8 +23,8 @@ from micromate.writes import plan_start_monitoring, plan_stop_monitoring
from minimateplus.transport import BaseTransport, SerialTransport, TcpTransport
from .errors import (
CallHomeInProgress, ChangeUnconfirmed, DeviceError, EventNotFound, MalformedReply, StaleEvent,
WrongUnit, translate,
AuditIncomplete, CallHomeInProgress, ChangeUnconfirmed, DeviceError, EventNotFound,
MalformedReply, StaleEvent, WrongUnit, translate,
)
from .change import CALL_HOME_MESSAGE, run_change
from .events import iso_of, make_event_id, stamp_of
@@ -133,7 +133,8 @@ class Series4Session:
The exceptions: `CallHomeInProgress` and `WrongUnit` release the line,
because the line itself is the problem; so does `ChangeUnconfirmed`, which
the change core raises only after a link fault or a ring, once the frame
has gone out. `AuditIncomplete` is an ordinary verdict: the line is kept.
has gone out. `AuditIncomplete` keeps the line unless its `release_line`
says the path would have hung up anyway (a ring, a link fault, a refusal).
"""
def __init__(self, address: UnitAddress, serial: str,
@@ -192,6 +193,14 @@ class Series4Session:
log.warning("%s at %s -- released the line: %s", type(exc).__name__,
self.address.key, exc)
raise
except AuditIncomplete as exc:
# A finish that failed on a path that hangs up anyway (ring, link
# fault, refusal) must still hang up; on a healthy path, keep the line.
if exc.release_line:
self.hang_up()
log.warning("AuditIncomplete at %s -- released the line: %s",
self.address.key, exc)
raise
except DeviceError:
# The operation's own verdict (event not found, stale id): the line
# is healthy, so keep it. Library errors still hang up below.
+71 -1
View File
@@ -15,7 +15,7 @@ from device_access_fakes import FakeMicromateClient # no
from sfm.device_access.access import DeviceAccess # noqa: E402
from sfm.device_access.errors import ( # noqa: E402
AuditIncomplete, AuditUnavailable, CallHomeInProgress, ChangeUnconfirmed, ConnectFailed, DeviceError,
NotSupported, UnitStateUnknown, WrongUnit,
NoAnswer, NotSupported, UnitStateUnknown, WrongUnit,
)
from sfm.device_access.models import UnitAddress # noqa: E402
@@ -694,3 +694,73 @@ def test_series3_monitor_status_decode_keeps_the_raw_flag():
assert (st.state_flag, st.is_monitoring) == (flag, monitoring)
assert _decode_monitor_status(bytes(12)).state_flag is None # no section[1]
assert _decode_monitor_status(b"").state_flag is None
# ── an audit finish that fails must not turn a hang-up into a held line ───────
def _reads_then(fake, exc):
"""read_run_state answers once (the state before the send), then raises."""
orig, n = fake.read_run_state, []
def flaky():
n.append(1)
if len(n) > 1:
raise exc
return orig()
fake.read_run_state = flaky
return fake
def _drain_raises(fake, exc):
def drain():
raise exc
fake.read_unsolicited = drain
return fake
_LOST = mm_proto.TimeoutError("no ack")
_HANG_UP_PATHS = {
"ring in place of the ack":
lambda: FakeMicromateClient(run_states=[0x00], execute_error=RingDetected("RADIO RING")),
"lost ack, ring on the follow-up":
lambda: _reads_then(FakeMicromateClient(run_states=[0x00], execute_error=_LOST),
RingDetected("RADIO RING")),
"lost ack, follow-up reads calling_home":
lambda: FakeMicromateClient(run_states=[0x00, 0x03], execute_error=_LOST),
"lost ack, follow-up unreadable":
lambda: _reads_then(FakeMicromateClient(run_states=[0x00], execute_error=_LOST),
mm_proto.TimeoutError("silent")),
"read-back raises":
lambda: _reads_then(FakeMicromateClient(run_states=[0x00]), mm_proto.TimeoutError("silent")),
"read-back rings":
lambda: _reads_then(FakeMicromateClient(run_states=[0x00]), RingDetected("RADIO RING")),
"read-back reads calling_home":
lambda: FakeMicromateClient(run_states=[0x00, 0x03]),
"ring before the send":
lambda: _drain_raises(FakeMicromateClient(run_states=[0x00]), RingDetected("RADIO RING")),
"link fault before the send":
lambda: _drain_raises(FakeMicromateClient(run_states=[0x00]), OSError("connection reset")),
"refused by execute":
lambda: FakeMicromateClient(run_states=[0x00], execute_error=OpcodeRefused("nope")),
}
@pytest.mark.parametrize("path", sorted(_HANG_UP_PATHS))
def test_a_finish_that_fails_on_a_hang_up_path_still_releases_the_line(path):
fake = _HANG_UP_PATHS[path]()
da = access(fake, audit=FinishFails())
with pytest.raises(AuditIncomplete) as e:
da.start_monitoring(ADDR, "UM20147")
assert e.value.release_line is True
assert "could not be finished: disk full" in str(e.value)
assert len(fake.executed) <= 1
assert released(fake, da)
def test_series3_a_cold_unit_during_a_change_is_not_retried():
fake = FakeMiniMateClient(fail=[mmp_proto.TimeoutError("cold")])
da = access3(fake)
with pytest.raises(NoAnswer):
da.start_monitoring(TCP3, "BE18193")
assert fake.writes == []
assert len(da.factory_calls) == 1 # the change path never takes _run's retry