Release v0.35.0 — 80 of 88 report fields from the file, and monitor logs (.MLG) #60

Merged
serversdown merged 50 commits from dev into main 2026-11-16 15:49:06 -05:00
6 changed files with 4779 additions and 3 deletions
Showing only changes of commit 6818e3023e - Show all commits

No files matched your search

+8 -3
View File
@@ -177,7 +177,9 @@ def _mic_units_mixed(sfm: SfmSide, ref: XmlReport, res: FieldResult) -> bool:
peak = max((abs(c) for c in counts), default=None)
return alt is not None and peak is not None and not _differs(alt(peak), res.bw or "")
got = series_pairs(sfm, ref, res.field)
alt = _other_mic_unit(sfm, _mic_table_units(ref))
# An interval column names its own unit; a sample table says it in its cells.
units = res.field if res.field.startswith("intervals.") else _mic_table_units(ref)
alt = _other_mic_unit(sfm, units)
if got is None or got[1] or alt is None:
return False
differing = [(j, cell) for j, cell, v in got[0] if _differs(v, cell)]
@@ -187,13 +189,16 @@ def _mic_units_mixed(sfm: SfmSide, ref: XmlReport, res: FieldResult) -> bool:
MIC_UNITS_MIXED = Carveout(
id="mic-units-mixed",
fields=("MicLPSPL", "samples.MicL"),
fields=("MicLPSPL", "samples.MicL", "intervals.MicL Peak psi(L)", "intervals.MicL Peak dB(L)"),
evidence=("Blastware's dB(L) / psi(L) labels do not hold for the mic on every report: 7 DL2 "
"reports print the mic peak in dB under a psi line, 3 the reverse, and some mix the "
"two inside one column -- K441L9IN.OT0W prints psi '0.000' / '-0.000' for counts of 1 "
"to 3 in a dB table, S353JTHU.DT0W psi rows then dB rows. On 19 DL2 events (14 "
"sample tables, 5 peaks) every mic cell SFM disagrees with is SFM's own value in the "
"other unit; a cell matching neither is still a mismatch. 2026-11-09."),
"other unit; a cell matching neither is still a mismatch. A histogram row can print "
"one unit in both its mic columns: I145HKWT.DY0H row 672 reads 95.92 under psi(L) "
"and dB(L) (count 5, dB), S353K894.OE0H rows 106 and 608 0.000 under both (count 2, "
"psi). 2026-11-09."),
applies=_mic_units_mixed,
)
BIN
View File
Binary file not shown.
File diff suppressed because it is too large. Load diff
BIN
View File
Binary file not shown.
File diff suppressed because it is too large. Load diff
+9
View File
@@ -544,3 +544,12 @@ def test_the_mixed_units_carveout_needs_every_cell_in_one_unit_or_the_other():
ref.sample_rows[0][i] = "50.00" # neither SFM's dB nor its psi
res = {r.field: r for r in compare(sfm_side(path.read_bytes()), ref, CARVEOUTS)}
assert res["samples.MicL"].verdict == "mismatch"
@pytest.mark.parametrize("path,column", [
(_UL / "I145HKWT.DY0H", "MicL Peak psi(L)"), # row 672: 95.92 in both mic columns (count 5: dB)
(_UL / "S353K894.OE0H", "MicL Peak dB(L)"), # rows 106, 608: 0.000 in both (count 2: psi)
])
def test_an_interval_printing_one_unit_in_both_mic_columns_is_accepted(path, column):
r = _res(path)[f"intervals.{column}"]
assert (r.verdict, r.carveout) == ("accepted", "mic-units-mixed"), r