Release v0.35.0 — 80 of 88 report fields from the file, and monitor logs (.MLG) #60
No files matched your search
@@ -135,6 +135,68 @@ All notable changes to seismo-relay are documented here.
|
||||
- No schema change.
|
||||
- The over-range flags are on the decoded event only: not stored in the
|
||||
DB, sidecar or `.h5` yet.
|
||||
- **Monitor logs (.MLG): SFM reads them and keeps each unit's monitoring
|
||||
timeline** (`feat/mlg-import`, merged 2026-11-16). Spec
|
||||
`docs/superpowers/specs/2026-11-09-mlg-unit-timeline-design.md`.
|
||||
- **Why (Brian, 2026-11-09):** every unit sends an `.MLG` at every call-in,
|
||||
whatever its mode. A continuous-mode unit sends no event file on a quiet
|
||||
day, so its `.MLG` is the only proof it was monitoring. That proof is what
|
||||
a shot report attaches for a unit that did not trigger. Outage history is
|
||||
the second use.
|
||||
- **The format, measured** (reference D.4, rewritten):
|
||||
- an 18-byte prefix, then length-led 292-byte records
|
||||
- each record ends in a CRC-16/AUG-CCITT over `[0:288]`, little-endian:
|
||||
3,329 / 3,329 records
|
||||
- `minimateplus/mlg_file.py` reads it, checking every record's checksum,
|
||||
and writes it: 16 / 16 real files rebuilt byte for byte
|
||||
- the old unused writer in `blastware_file.py` (big-endian, a zero CRC
|
||||
at the wrong end) is removed
|
||||
- `minimateplus/crc.py` is the one CRC, now used by
|
||||
`micromate/setup_block.py` too
|
||||
- **Storage:** new tables `mlg_files` (one row per file received) and
|
||||
`mlg_records` (one row per record, stored once). The original file is kept
|
||||
under `<store>/<serial>/mlg/`.
|
||||
- An empty file has no serial inside. It takes the longest known serial
|
||||
its `<serial><counter>` name starts with, or is stored as unresolved,
|
||||
never guessed.
|
||||
- Only plain serials become directories.
|
||||
- **The timeline** (`sfm/mlg_timeline.py`):
|
||||
- **sessions:** how each ended, its events, and its trigger level as
|
||||
logged
|
||||
- **gaps and what each means:** call-in, scheduled off, lost power,
|
||||
stopped by a person, memory full, no restart after a call-in, records
|
||||
missing
|
||||
- **clock steps:** the unit's clock steps back an hour at its first
|
||||
call-in after daylight saving ends
|
||||
- **call-ins:** delivered, no_file (a Modem Exit that left no file) and
|
||||
nothing_new (an empty file)
|
||||
- **"Was it monitoring at T"** answers monitoring / not_monitoring / unknown,
|
||||
naming the records and file behind the answer. It never claims more than
|
||||
the records show: a gap across a missing call-in number (files are
|
||||
numbered) reads unknown.
|
||||
- **Routes:** `POST /db/import/mlg_file`; `GET /db/units/{serial}/timeline`,
|
||||
`/db/units/{serial}/monitoring_at`, `/db/mlg_records` and
|
||||
`/db/mlg_files/{id}` (the original, for printing).
|
||||
- **Tools:** `scripts/import_mlg_dir.py` (bulk import, with a dry run) and
|
||||
`scratch/check_mlg_vs_events.py` (cross-check against the event files'
|
||||
footers).
|
||||
- **Measured on DL2's 1,273-file sample** (BE6907 and BE12844 from 2026,
|
||||
BE8081 from 2018–19):
|
||||
- 0 errors, 0 unresolved
|
||||
- BE8081's 785 Event Recorded records match its 785 event files, both ways
|
||||
- every recorded event falls inside a session
|
||||
- two real outages: BE6907 recorded nothing for 14 days from 2026-10-07,
|
||||
and BE8081 didn't restart after a failed call over Labor Day 2019
|
||||
- ⚠ **Operational:**
|
||||
- Two new tables are created on first start: no migration, no backfill,
|
||||
no `TOOL_VERSION` bump (the event decode and the `.h5` files are
|
||||
unchanged).
|
||||
- Nothing arrives until `.MLG`s are imported. The watcher does not forward
|
||||
them yet (`../series3-watcher`, Brian's call).
|
||||
- DL2's full set (~86,000 files) loads with `scripts/import_mlg_dir.py`.
|
||||
Load it from a robocopy copy: a Windows zip shifts summer file dates by
|
||||
an hour.
|
||||
- Terra-View shows none of it yet.
|
||||
|
||||
### Fixed
|
||||
- **The mic's own range: a range-1 mic reads an eighth.**
|
||||
@@ -236,6 +298,13 @@ All notable changes to seismo-relay are documented here.
|
||||
- **Reference D.6, "Reading a mismatch":** 256, 4,096 and 65,536 mean a number
|
||||
outgrew its 8-, 12- or 16-bit box. Every case so far is listed (Brian's
|
||||
observation, 2026-11-05).
|
||||
- **Reference D.4, rewritten:** the `.MLG` format, measured.
|
||||
- Its framing, CRC and fields.
|
||||
- How Blastware writes the files: one per call-in, no record repeated, and
|
||||
a Modem Exit that is not a file's last record was a call that left no file.
|
||||
- How a session appears, and the cross-check against the event files.
|
||||
- The old D.4.1–D.4.3 (a 308-byte header, a CRC at each record's start) are
|
||||
kept, marked retracted.
|
||||
|
||||
## v0.34.0 — 2026-11-04
|
||||
|
||||
|
||||
@@ -31,7 +31,7 @@ Read this first when picking the project back up.
|
||||
3. switch ingest so reports are kept only for checking (retire the overlay)
|
||||
4. stop the watchers forwarding reports
|
||||
- Until step 3, prod keeps the report as truth wherever one exists.
|
||||
- **🔑 Monitor logs (.MLG) and each unit's timeline (2026-11-13, `feat/mlg-import`).**
|
||||
- **🔑 Monitor logs (.MLG) and each unit's timeline (merged to `dev` 2026-11-16; next release).**
|
||||
- **What:** every unit sends an `.MLG` at every call-in, in every mode. SFM reads it
|
||||
(`minimateplus/mlg_file.py`, reference D.4) and keeps each unit's monitoring timeline:
|
||||
sessions, gaps and what they mean, clock steps, and the call-ins, including calls that
|
||||
|
||||
Reference in new issue
Block a user