""" minimateplus/decode_check_carveouts.py — the proven ways Blastware's report differs from the instrument's data. Every disagreement between SFM and Blastware is SFM's bug until shown otherwise. A carve-out is that showing: the fields it covers, the rule it applies, and evidence that does not rest on SFM's own output -- Blastware contradicting itself, the instrument's own data, a third source, or Instantel documentation. `compare` turns a covered mismatch into `accepted` only when the rule holds, and every run counts the events each carve-out covers. Pure: no I/O, and no import from `sfm/`. """ from __future__ import annotations from dataclasses import dataclass from typing import Callable from .bw_xml_report import XmlReport from .decode_check import FieldResult, SfmSide, _printed_number, series_pairs, matches_printed @dataclass(frozen=True) class Carveout: id: str fields: tuple[str, ...] # exact names, or prefixes ending in "." evidence: str applies: Callable[[SfmSide, XmlReport, FieldResult], bool] _TOL = 0.0006 def _at_ceiling(value: float, r: float) -> bool: """SFM's value sits at the range ceiling: a decoder unit or two past nominal full scale is the clipped count itself (32016 = 10.005 in/s). An 8x Sensitive-range value is far above the band and does not qualify.""" return r - _TOL <= abs(value) <= r * 1.01 def _clamped(printed: str, r: float) -> bool: if printed.strip() == "OORANGE": return True p = _printed_number(printed) return p is not None and abs(p[0]) >= r - _TOL def _saturation(sfm: SfmSide, ref: XmlReport, res: FieldResult) -> bool: try: r = float(ref.scalars["GeoRange"]) except (KeyError, ValueError): return False if res.field in ("TranPPV", "VertPPV", "LongPPV"): v = sfm.values.get(res.field) return v is not None and _clamped(res.bw or "", r) and _at_ceiling(float(v), r) if res.field == "PeakVectorSum": # A vector sum can exceed the range without any clipping, so only # Blastware's OORANGE counts. SFM's sum is bounded by three channels at # the ceiling (11.55 on T438HGTZ.B30W), and a channel Blastware itself # clamped must be the one SFM has at the ceiling -- an unclipped channel # read 8x high on the Sensitive range does not qualify. pvs = sfm.values.get("PeakVectorSum") return ((res.bw or "").strip() == "OORANGE" and pvs is not None and r - _TOL <= float(pvs) <= 3 ** 0.5 * r * 1.01 and any(_clamped(ref.scalars.get(f, ""), r) and sfm.values.get(f) is not None and _at_ceiling(float(sfm.values[f]), r) for f in ("TranPPV", "VertPPV", "LongPPV"))) got = series_pairs(sfm, ref, res.field) if got is None or got[1]: return False differing = [(cell, v) for _, cell, v in got[0] if not matches_printed(v, cell)] return bool(differing) and all( _clamped(cell, r) and _at_ceiling(v, r) and (cell.strip() == "OORANGE" or (v >= 0) == (_printed_number(cell)[0] >= 0)) for cell, v in differing) SATURATION = Carveout( id="saturation", fields=("TranPPV", "VertPPV", "LongPPV", "PeakVectorSum", "samples.Tran", "samples.Vert", "samples.Long", "intervals.Tran Peak in/s", "intervals.Vert Peak in/s", "intervals.Long Peak in/s"), evidence=("Blastware clamps a clipped channel to the range maximum and prints OORANGE; " "the file holds counts past full scale (32016 counts = 10.005 in/s observed). " "scratch/verify_against_ascii.py, 2026-08-28."), applies=_saturation, ) def _interval_count_is_duration(sfm: SfmSide, ref: XmlReport, res: FieldResult) -> bool: """Blastware's count exceeds the intervals in its own table, and SFM decoded exactly the table's.""" p = _printed_number(res.bw or "") n = sfm.values.get("NumberofIntervals") rows = len(ref.intervals or []) return p is not None and n is not None and rows == n and p[0] > n INTERVAL_COUNT_IS_DURATION = Carveout( id="interval-count-is-duration", fields=("NumberofIntervals",), evidence=("Blastware's Number of Intervals is (stop - start) / interval from the file's " "footer times -- exact on T193KSWP.FF0H (2,880), M462KSWR.1R0H (1,650) and " "T193KY0A.740H (6,390). Its own interval table lists the intervals the file " "holds: one block (30 at 2 s) fewer when the unit never wrote the last minute. " "2026-11-02."), applies=_interval_count_is_duration, ) _MIC_UNITS = ("in/s and dB(L)", "in/s and psi(L)") def _units_is_a_display_preference(sfm: SfmSide, ref: XmlReport, res: FieldResult) -> bool: """Both sides say the event has a mic; they differ only in dB against psi.""" return (" ".join((res.bw or "").split()) in _MIC_UNITS and sfm.values.get("Units") in _MIC_UNITS) UNITS_IS_A_DISPLAY_PREFERENCE = Carveout( id="units-is-a-display-preference", fields=("Units",), evidence=("dB(L) or psi(L) is Blastware's display preference on the PC when it wrote the " "report, not the unit's: in report-write order (the _XML.XML mtimes) DL2's 70,034 " "reports switch fleet-wide in 61 clean runs, every unit at once, and no byte or " "bit of the event file separates the two (k-240 .. k+520, nor the 1.2 KB before " "the footer). 2026-11-03."), applies=_units_is_a_display_preference, ) CARVEOUTS: tuple[Carveout, ...] = (SATURATION, INTERVAL_COUNT_IS_DURATION, UNITS_IS_A_DISPLAY_PREFERENCE)