""" Setup and note fields read from a Blastware event file alone (#44, #45). Every expected value below comes from Blastware's own output for the same file -- its ASCII report or its `_XML.XML` event report -- or, for the bench file with neither, from the record length and the MiniMate Plus spec, as written up in #44/#45. None is derived from the decoder under test. The STRT record's bytes are not these fields: STRT[18] is the record-type marker (0x46 waveform, 0x0A histogram), which is why every waveform used to read "70 s". """ from __future__ import annotations from pathlib import Path import pytest from minimateplus.event_file_io import read_blastware_file _FIX = Path(__file__).resolve().parent / "fixtures" # (file, sample rate, record time s, pre-trigger samples, total samples) _WAVEFORMS = [ # ASCII report: 1024 sps, 3.0 s, -0.25 s; 3328 samples per channel. ("5-11-26/M529LL1A.SP0", 1024, 3.0, 256, 3328), # ASCII report: 1024 sps, 1.0 s, -0.25 s. ("decode-re-5-8-26/event-c/M529LK44.AB0", 1024, 1.0, 256, 1280), # #44/#45: BE9441 bench at 4096 sps, 5 s, 0.25 s -> 21,504 samples. ("minimate-bench-10-26-26-blastware/blastware/K441LTOF.ZI0", 4096, 5.0, 1024, 21504), # XML: setup "BE16352.set", 1024 sps, 1.0 s, -0.247 s, 1277 sample rows. ("bw-import-fields-10-29-26/R352HIUI.F40W", 1024, 1.0, 253, 1277), ] @pytest.mark.parametrize("rel,sr,rt,pretrig,total", _WAVEFORMS) def test_waveform_setup_fields_come_from_the_file(rel, sr, rt, pretrig, total): ev = read_blastware_file(_FIX / rel) assert ev.sample_rate == sr assert ev.rectime_seconds == pytest.approx(rt) assert ev.pretrig_samples == pretrig assert ev.total_samples == total # (file, sample rate) -- ASCII report / XML _HISTOGRAMS = [ ("histogram-mic-off-10-26-26/K441LTOK.QZ0", 2048), ("ts-fix/K441LKZU.C30H", 1024), ("bw-import-fields-10-29-26/M529L4XQ.R30H", 1024), ] @pytest.mark.parametrize("rel,sr", _HISTOGRAMS) def test_histogram_sample_rate_comes_from_the_file(rel, sr): ev = read_blastware_file(_FIX / rel) assert ev.sample_rate == sr @pytest.mark.parametrize("rel,sr", _HISTOGRAMS) def test_histogram_has_no_record_time_or_pretrigger(rel, sr): # Blastware reports neither for a histogram; the STRT record-type byte # (0x0A = 10) is not a record time. ev = read_blastware_file(_FIX / rel) assert ev.rectime_seconds is None assert ev.pretrig_samples is None # (file, setup name, project, client, operator, sensor location) _NOTES = [ # ASCII report; default labels, location spelled "Seis Loc:". ("5-11-26/M529LL1A.SP0", "Standard Recording Setup", "Test-5-8-26", "New Client", "Terra-Mechanics - Harrison", "Still Catbed."), # ASCII report; location spelled "Seis. Loc:". BE9441's bench setup is # saved as "Standard Recording Setup.set" (#45). ("histogram-mic-off-10-26-26/K441LTOK.QZ0", "Standard Recording Setup.set", "TestUnit-Minimate", "Terra-Mechanics", "Terra-Mechanics Inc. - Harrison", "Test unit 1"), # XML; a setup not named "Standard Recording Setup". ("bw-import-fields-10-29-26/R352HIUI.F40W", "BE16352.set", "JV 241 - 1425 Spanlers Mill Rad", "Walsh Granite JV", "Terra-Mechanics Inc- D. Harrison", "Loc #1 - 1425 Spanlers Mill Rd"), # XML (Test Loc only); the operator relabelled the # four note slots "Location:", "Client:", "User Name:", "General:" and # filled in only the first. Slots are positional, as in the ASCII parser. ("bw-import-fields-10-29-26/M529L4XQ.R30H", "Standard Recording Setup", "Test Loc", None, None, None), ] @pytest.mark.parametrize("rel,setup,project,client,operator,location", _NOTES) def test_notes_come_from_the_file_by_position(rel, setup, project, client, operator, location): pi = read_blastware_file(_FIX / rel).project_info assert pi.setup_name == setup assert pi.project == project assert pi.client == client assert pi.operator == operator assert pi.sensor_location == location def test_import_without_a_report_stores_the_file_fields(tmp_path: Path): """The watcher path with no ASCII report: the sidecar carries what the file holds, not blanks and not the STRT bytes.""" from sfm.waveform_store import WaveformStore src = _FIX / "bw-import-fields-10-29-26/R352HIUI.F40W" store = WaveformStore(tmp_path / "waveforms") store.save_imported_bw(src.read_bytes(), source_path=src) sc = store.load_sidecar("BE16352", src.name) assert sc["event"]["sample_rate"] == 1024 assert sc["event"]["rectime_seconds"] == pytest.approx(1.0) assert sc["event"]["pretrig_samples"] == 253 assert sc["project_info"]["project"] == "JV 241 - 1425 Spanlers Mill Rad" assert sc["project_info"]["sensor_location"] == "Loc #1 - 1425 Spanlers Mill Rd" # ── #41: the record type comes from the bytes ─────────────────────────────── # STRT[18] is the record-type byte: 0x46 on every one of DL2's 6,577 waveform # files, 0x0A on every one of its 63,535 histograms (measured 2026-10-29). from minimateplus import blastware_file as _bw # noqa: E402 from minimateplus.event_file_io import decode_blastware_bytes # noqa: E402 _TYPES = [ ("bw-import-fields-10-29-26/R352HIUI.F40W", "Waveform"), ("bw-import-fields-10-29-26/M529L4XQ.R30H", "Histogram"), ("5-11-26/M529LL1A.SP0", "Waveform"), # name carries no type ("histogram-mic-off-10-26-26/K441LTOK.QZ0", "Histogram"), # name carries no type ] @pytest.mark.parametrize("rel,want", _TYPES) def test_record_type_comes_from_the_bytes_without_a_name(rel, want): assert decode_blastware_bytes((_FIX / rel).read_bytes(), name=None).record_type == want def test_the_bytes_win_over_a_filename_that_disagrees(caplog): raw = (_FIX / "bw-import-fields-10-29-26/M529L4XQ.R30H").read_bytes() ev = decode_blastware_bytes(raw, name="M529L4XQ.R30W") assert ev.record_type == "Histogram" assert "record type" in caplog.text def test_an_unknown_type_byte_is_unknown_not_a_guess(): raw = bytearray((_FIX / "bw-import-fields-10-29-26/R352HIUI.F40W").read_bytes()) raw[_bw._WAVEFORM_HEADER_SIZE + 18] = 0x99 ev = decode_blastware_bytes(bytes(raw), name=None) assert ev.record_type is None assert any("record type" in p for p in ev.decode_problems)