# SFM device access, phase 1a — Implementation Plan > **For agentic workers:** REQUIRED SUB-SKILL: Use superpowers:subagent-driven-development (recommended) or superpowers:executing-plans to implement this plan task-by-task. Steps use checkbox (`- [ ]`) syntax for tracking. **Goal:** SFM can identify a unit, read its status and read its settings through one series-neutral contract. The unit is named by serial + address and works the same for a Series 3 (`BE…`/`BA…`) or Series 4 (`UM…`) unit. Micromates get a held session ("stay on the line"). **Architecture:** A new package `sfm/device_access/` sits between the `/device/*` handlers and the two device libraries: - The serial prefix picks a series adapter. - A per-unit lock gives one connection per unit. - Series-4 sessions stay open, with keep-alive, idle hang-up and ring safety. - Every library exception becomes one of a few typed errors with a fixed HTTP status. Handlers take an optional `serial`. With it they return the shared models; without it they run exactly as today. **Tech Stack:** Python ≥ 3.10, FastAPI 0.135 (already used), pyserial (already a dependency), pytest. No new dependencies. **Spec:** `docs/superpowers/specs/2026-10-20-sfm-series4-parity-design.md`. This plan is phase **1a**. Event list/download (1b) and the webapp (1c) are separate plans. ## Global Constraints - **Reads only.** The Series-4 path may call only `connect()`, `get_state()`, `get_setup()`, `get_event_count()`, `read_unsolicited()` and `protocol.poll()`. The Series-3 path may call only `connect()`, `poll()` and `get_monitor_status()`. Nothing that changes a unit is sent in this phase. - **Never put Series-3 bytes on a Micromate's wire.** Nothing under `sfm/device_access/s4.py` may import `minimateplus.protocol`, `minimateplus.framing` or `minimateplus.client`. `SESSION_RESET` (`41 03`) has never been sent to a Micromate. Only `minimateplus.transport` is shared. - **Requests without `serial` behave exactly as today.** The legacy Series-3 code path in each handler is left untouched. - Serial prefixes: `UM` → Series 4; `BE`, `BA` → Series 3; anything else → 422. Serials are compared after `.strip().upper()`. - Timings (spec): lock wait **20 s**, keep-alive **60 s**, idle hang-up **300 s**, reaper tick **5 s**. - Error statuses (spec): | status | when | |---|---| | 503 | could not connect / connection lost / unit started calling home | | 504 | connected, the unit did not answer | | 423 | unit busy | | 409 | wrong unit | | 422 | bad input | | 502 | malformed reply | | 501 | not supported yet | - Default serial baud when the caller gives none: Series 3 **38400**, Series 4 **115200**. - ⚠ **Handlers are called directly in tests.** Their FastAPI `Query(...)` defaults are `FieldInfo` objects, not values, so every test call must pass every parameter explicitly. The same applies to one handler calling another. `httpx` is not installed, so `TestClient` tests are skipped silently; do not use them. - Feature branch: do **not** edit `CHANGELOG.md` (it is written on `dev` at merge). - Every commit message ends with: ``` Co-Authored-By: Claude Opus 5.5 Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44 ``` - Run tests with `.venv/bin/python -m pytest`. The full suite currently reports **16 failed, 541 passed, 46 skipped**: the 16 failures are pre-existing, in `test_bw_ascii_report.py` (15) and `test_event_file_io.py` (1). That baseline must not change except by new passing tests. ## Review Focus 1. **A serial typed in lower case or with spaces** (`" um20147"`) is accepted and treated as `UM20147`, never rejected → Task 3. 2. **Two requests for the same unit at once** (the webapp fires three): the second waits, then gets 423. A second connection is never opened → Tasks 4 and 8. 3. **The modem dropped an idle line** (2-minute TCP idle timeout): the next request calls up again quietly instead of failing → Task 8. 4. **A different unit answers at the address** (moved modem, stale IP): 409, the connection is closed, and nothing further is sent → Tasks 5 and 6. 5. **`RADIO RING` arrives mid-request or while idle**: the line is released at once, the caller gets a clear 503, and the next request calls up fresh → Tasks 6 and 8. --- ## File Structure | path | responsibility | |---|---| | `micromate/client.py` (modify) | fix `is_open()`; add `get_event_count()` and `read_unsolicited()` | | `sfm/device_access/__init__.py` | public exports | | `sfm/device_access/errors.py` | typed errors with HTTP statuses; `translate()` | | `sfm/device_access/series.py` | serial normalisation; prefix → series | | `sfm/device_access/models.py` | `UnitAddress`, `UnitInfo`, `UnitStatus`, `UnitSettings` | | `sfm/device_access/locks.py` | per-unit lock with timeout | | `sfm/device_access/s3.py` | Series-3 adapter (connect-per-request) | | `sfm/device_access/s4.py` | `RingWatchTransport`, `Series4Session`, Series-4 operations | | `sfm/device_access/access.py` | `DeviceAccess`: dispatch, sessions, hang-up, reaper | | `sfm/server.py` (modify) | `serial` on `/device/info`, `/device/connect`, `/device/monitor/status`; new `GET /device/settings`, `POST /device/hangup` | | `tests/device_access_fakes.py` | test-only fakes of both clients | | `tests/test_device_access_core.py` | errors, series, models, locks | | `tests/test_device_access_s3.py` | Series-3 adapter | | `tests/test_device_access_s4.py` | ring watch, session, Series-4 operations | | `tests/test_device_access.py` | `DeviceAccess` + contract tests | | `tests/test_server_device_access.py` | handlers | --- ### Task 1: Fix `MicromateClient.is_open()` `is_connected` is a **property** on `BaseTransport` (`minimateplus/transport.py:59`). `MicromateClient.is_open()` *calls* it, so on every real transport it raises `TypeError: 'bool' object is not callable`. The test double in `tests/test_micromate_client.py` defines `is_connected` as a **method**, which is why no test caught it. Sessions depend on `is_open()`. **Files:** - Modify: `micromate/client.py` (`is_open`, around line 130) - Modify: `tests/test_micromate_client.py` (`ScriptedTransport`, around line 112; the test around line 406) **Interfaces:** - Produces: `MicromateClient.is_open() -> bool`, now correct on real transports. - [ ] **Step 1: Make the test double match the real interface, and add a real-transport test** In `tests/test_micromate_client.py`, change `ScriptedTransport.is_connected` to a property: ```python @property def is_connected(self) -> bool: return self._connected ``` In `test_the_client_owns_the_transport` (around line 406), change `t.is_connected()` to `t.is_connected`. Then run `grep -n "is_connected" tests/test_micromate_*.py` and convert any other method-style `is_connected` in those test doubles the same way. Append this test: ```python def test_is_open_works_on_a_real_transport(): """`is_connected` is a PROPERTY on BaseTransport. is_open() used to call it, which raised TypeError on every real transport -- hidden because the test double defined it as a method.""" from minimateplus.transport import TcpTransport mm = MicromateClient(TcpTransport("127.0.0.1", port=9)) # never connected assert mm.is_open() is False ``` - [ ] **Step 2: Run the tests and watch them fail** Run: `.venv/bin/python -m pytest tests/test_micromate_client.py -q` Expected: `test_is_open_works_on_a_real_transport` and `test_the_client_owns_the_transport` FAIL with `TypeError: 'bool' object is not callable`. - [ ] **Step 3: Fix `is_open`** In `micromate/client.py`: ```python def is_open(self) -> bool: # `is_connected` is a PROPERTY on BaseTransport. Calling it raised # TypeError on every real transport; only a test double that defined # it as a method hid that. return bool(self._transport.is_connected) ``` - [ ] **Step 4: Run the tests and watch them pass** Run: `.venv/bin/python -m pytest tests/test_micromate_*.py -q` Expected: all pass. - [ ] **Step 5: Commit** ```bash git add micromate/client.py tests/test_micromate_client.py git commit -m "fix(micromate): is_open() called a property -- TypeError on every real transport" -m "Hidden because the test double defined is_connected as a method; it is now a property, matching BaseTransport." -m "Co-Authored-By: Claude Opus 5.5 Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44" ``` --- ### Task 2: Client additions for status and sessions Two reads move into the client: - `get_event_count()`. `0x06` content[0:4] is the event count: 3/3 against the chain walk, and THOR's own `ReadEventRecordCount` agrees. Until now it was decoded only in `bridges/mm_client_check.py`. - `read_unsolicited()`. It reads whatever the unit sent unprompted, **sending nothing**. The session uses it to notice `RADIO RING` while idle. **Files:** - Modify: `micromate/client.py` (constants near the other `_MS_*` constants; methods next to `get_state`) - Test: `tests/test_micromate_client.py` **Interfaces:** - Produces: - `MicromateClient.get_event_count() -> int`; raises `ProtocolError` if the content is under 4 bytes. - `MicromateClient.read_unsolicited() -> bytes`; one transport read, nothing written. - [ ] **Step 1: Capture a real `0x06` read from UM20147 (read-only)** The bench unit is on `/dev/ttyACM0`; `dialout` needs `sg`. This sends only reads. ```bash cat > /tmp/mm_capture_0x06.py <<'EOF' import sys sys.path.insert(0, ".") from minimateplus.transport import SerialTransport from micromate.client import MicromateClient with MicromateClient(SerialTransport("/dev/ttyACM0", 115200)) as mm: mm.connect() data = mm.protocol.read_storage_range() refs = mm.list_events(with_records=False) print("DATA_HEX =", data.hex()) print("CHAIN_WALK_COUNT =", len(refs)) EOF sg dialout -c ".venv/bin/python /tmp/mm_capture_0x06.py" ``` Record both printed values. The expected count in the test is `CHAIN_WALK_COUNT`: the chain walk is an independent count, never this method's own output. - [ ] **Step 2: Write the failing tests** Append to `tests/test_micromate_client.py`. Paste the captured hex and count where marked; both are values from Step 1, not choices. ```python # ── get_event_count() / read_unsolicited() ──────────────────────────────────── # 0x06 response data captured from UM20147 (11.0BD) by Task 2, Step 1. The # expected count is that session's independent chain-walk count. SR_UM20147 = bytes.fromhex("PASTE DATA_HEX FROM STEP 1") SR_UM20147_CHAIN_WALK_COUNT = 0 # replace 0 with CHAIN_WALK_COUNT from Step 1 def test_event_count_is_content_0_4_and_matches_the_chain_walk(): mm, t = client([frame(0xF9, SR_UM20147, flags=FLAGS_THOR)]) assert mm.get_event_count() == SR_UM20147_CHAIN_WALK_COUNT assert [w[5] for w in t.written] == [0x06] def test_a_truncated_storage_range_raises(): mm, _ = client([frame(0xF9, bytes(CONTENT) + b"\x00\x05", flags=FLAGS_THOR)]) with pytest.raises(ProtocolError, match="storage range"): mm.get_event_count() def test_read_unsolicited_sends_nothing_and_returns_what_arrived(): """Used to spot RADIO RING on an idle session. It must never write.""" mm, t = client([b"\r\nRADIO RING\r\n"]) assert mm.read_unsolicited() == b"\r\nRADIO RING\r\n" assert t.written == [] ``` - [ ] **Step 3: Run the tests and watch them fail** Run: `.venv/bin/python -m pytest tests/test_micromate_client.py -q -k "event_count or storage_range or unsolicited"` Expected: FAIL with `AttributeError: 'MicromateClient' object has no attribute 'get_event_count'` (and the same for `read_unsolicited`). - [ ] **Step 4: Implement** In `micromate/client.py`, next to the `_MS_*` constants: ```python # 0x06 storage range. content[0:4] is the event count: 3/3 against the chain # walk, and THOR's ReadEventRecordCount agrees. content[4:8] is very likely # the monitor-log count -- graded a strong candidate, not settled, so not exposed. _SR_EVENT_COUNT = slice(0, 4) ``` And these methods, after `get_state`: ```python def get_event_count(self) -> int: """`SUB 0x06` -- events stored. One read; no chain walk.""" c = _content(self._proto.read_storage_range()) if len(c) < 4: raise ProtocolError(f"storage range content is {len(c)} B, need at least 4") return int.from_bytes(c[_SR_EVENT_COUNT], "big") def read_unsolicited(self) -> bytes: """Whatever the unit sent unprompted. **Sends nothing.** One transport read. Bytes between commands are noise to the protocol (every request resets the parser), so reading them here takes nothing the protocol needs. A session calls this while idle to notice RADIO RING without waiting for its next keep-alive. """ return self._transport.read(4096) ``` - [ ] **Step 5: Run the tests and watch them pass** Run: `.venv/bin/python -m pytest tests/test_micromate_*.py -q` Expected: all pass. - [ ] **Step 6: Commit** ```bash git add micromate/client.py tests/test_micromate_client.py git commit -m "feat(micromate): get_event_count() and read_unsolicited()" -m "0x06 content[0:4] moves from the bench tool into the client, tested against a real UM20147 read and its chain-walk count. read_unsolicited() reads without sending, for spotting RADIO RING on an idle session." -m "Co-Authored-By: Claude Opus 5.5 Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44" ``` --- ### Task 3: Core types — errors, series, models **Files:** - Create: `sfm/device_access/__init__.py`, `sfm/device_access/errors.py`, `sfm/device_access/series.py`, `sfm/device_access/models.py` - Test: `tests/test_device_access_core.py` **Interfaces:** - Produces: - `errors.py`: `DeviceError` (base, `.http_status`); subclasses `BadRequest` 422, `NotSupported` 501, `WrongUnit` 409, `UnitBusy` 423, `ConnectFailed` 503, `CallHomeInProgress` 503, `NoAnswer` 504, `MalformedReply` 502; and `translate(exc: BaseException, *, connecting: bool) -> DeviceError`. - `series.py`: `normalise_serial(serial: str) -> str`; `series_for_serial(serial: str) -> int` (raises `BadRequest`). - `models.py`: `UnitAddress(host: Optional[str], tcp_port: Optional[int], port: Optional[str], baud: Optional[int])` (frozen; `.key -> str`; raises `BadRequest` if neither host nor port); dataclasses `UnitInfo`, `UnitStatus`, `UnitSettings` (fields below). - [ ] **Step 1: Write the failing tests** Create `tests/test_device_access_core.py`: ```python """Core types of sfm.device_access: errors, series selection, models.""" from __future__ import annotations import os import sys import pytest sys.path.insert(0, os.path.dirname(os.path.dirname(os.path.abspath(__file__)))) import micromate.protocol as mm_proto # noqa: E402 import minimateplus.protocol as mmp_proto # noqa: E402 from sfm.device_access.errors import ( # noqa: E402 BadRequest, ConnectFailed, DeviceError, MalformedReply, NoAnswer, translate, ) from sfm.device_access.models import UnitAddress # noqa: E402 from sfm.device_access.series import normalise_serial, series_for_serial # noqa: E402 # ── series ──────────────────────────────────────────────────────────────────── @pytest.mark.parametrize( "serial, series", [("UM20147", 4), ("BE18193", 3), ("BA4521", 3), (" um20147 ", 4), ("be11529", 3)], ) def test_the_prefix_picks_the_series(serial, series): assert series_for_serial(serial) == series def test_serials_are_normalised(): assert normalise_serial(" um20147\n") == "UM20147" @pytest.mark.parametrize("serial", ["", "UM", "XX12345", "12345", "MP1234"]) def test_an_unknown_or_bare_prefix_is_a_bad_request(serial): with pytest.raises(BadRequest, match="UM"): series_for_serial(serial) # ── errors ──────────────────────────────────────────────────────────────────── @pytest.mark.parametrize( "exc, connecting, cls, status", [ (mm_proto.TimeoutError("no frame"), False, NoAnswer, 504), (mmp_proto.TimeoutError("no frame"), False, NoAnswer, 504), (mm_proto.ChecksumError("bad"), False, MalformedReply, 502), (mmp_proto.ProtocolError("bad"), False, MalformedReply, 502), (ConnectionRefusedError("refused"), True, ConnectFailed, 503), (OSError("reset"), False, ConnectFailed, 503), ], ) def test_library_exceptions_translate_to_typed_errors(exc, connecting, cls, status): out = translate(exc, connecting=connecting) assert isinstance(out, cls) assert out.http_status == status def test_connect_and_mid_session_failures_read_differently(): assert "could not connect" in str(translate(OSError("x"), connecting=True)) assert "connection lost" in str(translate(OSError("x"), connecting=False)) def test_a_device_error_passes_through_unchanged(): e = NoAnswer("quiet") assert translate(e, connecting=False) is e def test_anything_else_becomes_a_plain_device_error(): out = translate(ValueError("boom"), connecting=False) assert type(out) is DeviceError and out.http_status == 500 # ── models ──────────────────────────────────────────────────────────────────── def test_an_address_needs_a_host_or_a_port(): with pytest.raises(BadRequest): UnitAddress(host=None, tcp_port=None, port=None, baud=None) def test_the_lock_key_names_the_physical_link(): assert UnitAddress(host="10.0.0.5", tcp_port=9034, port=None, baud=None).key == "tcp:10.0.0.5:9034" assert UnitAddress(host=None, tcp_port=None, port="/dev/ttyACM0", baud=115200).key == "serial:/dev/ttyACM0" ``` - [ ] **Step 2: Run the tests and watch them fail** Run: `.venv/bin/python -m pytest tests/test_device_access_core.py -q` Expected: collection ERROR, `ModuleNotFoundError: No module named 'sfm.device_access'`. - [ ] **Step 3: Implement** `sfm/device_access/errors.py`: ```python """Typed device errors, each with the HTTP status the endpoints return.""" from __future__ import annotations import micromate.protocol as _mm_proto import minimateplus.protocol as _mmp_proto class DeviceError(Exception): http_status = 500 class BadRequest(DeviceError): http_status = 422 class NotSupported(DeviceError): http_status = 501 class WrongUnit(DeviceError): http_status = 409 class UnitBusy(DeviceError): http_status = 423 class ConnectFailed(DeviceError): http_status = 503 class CallHomeInProgress(DeviceError): http_status = 503 class NoAnswer(DeviceError): http_status = 504 class MalformedReply(DeviceError): http_status = 502 _TIMEOUTS = (_mm_proto.TimeoutError, _mmp_proto.TimeoutError) _PROTOCOL = (_mm_proto.ProtocolError, _mmp_proto.ProtocolError) def translate(exc: BaseException, *, connecting: bool) -> DeviceError: """Map a library exception to a typed error. Order matters: each library's TimeoutError is a ProtocolError subclass, and the builtin TimeoutError (a failed TCP connect) is an OSError. """ if isinstance(exc, DeviceError): return exc if isinstance(exc, _TIMEOUTS): return NoAnswer(f"the unit did not answer: {exc}") if isinstance(exc, _PROTOCOL): return MalformedReply(f"bad reply from the unit: {exc}") if isinstance(exc, OSError): what = "could not connect" if connecting else "connection lost" return ConnectFailed(f"{what}: {exc}") return DeviceError(f"device error: {exc}") ``` `sfm/device_access/series.py`: ```python """Which series a unit is, from its serial prefix (decided with Brian, 2026-10-20).""" from __future__ import annotations from .errors import BadRequest SERIES_BY_PREFIX = {"UM": 4, "BE": 3, "BA": 3} def normalise_serial(serial: str) -> str: return (serial or "").strip().upper() def series_for_serial(serial: str) -> int: s = normalise_serial(serial) for prefix, series in SERIES_BY_PREFIX.items(): if s.startswith(prefix) and len(s) > len(prefix): return series raise BadRequest( f"unknown serial {serial!r}: expected UM... (Series 4) or BE.../BA... (Series 3)" ) ``` `sfm/device_access/models.py`: ```python """Series-neutral models. Every operation returns the same shape for both series; anything only one series has goes under `detail`.""" from __future__ import annotations from dataclasses import dataclass, field from typing import Any, Dict, Optional from .errors import BadRequest @dataclass(frozen=True) class UnitAddress: host: Optional[str] tcp_port: Optional[int] port: Optional[str] baud: Optional[int] def __post_init__(self) -> None: if not self.host and not self.port: raise BadRequest( "specify 'host' (TCP, e.g. ?host=10.0.0.5&tcp_port=9034) " "or 'port' (serial, e.g. ?port=/dev/ttyACM0)" ) @property def key(self) -> str: """One key per physical link -- what the per-unit lock is keyed on.""" if self.host: return f"tcp:{self.host}:{self.tcp_port}" return f"serial:{self.port}" @dataclass class UnitInfo: serial: str series: int model: Optional[str] firmware: Optional[str] monitoring: Optional[bool] active_setup: Optional[str] detail: Dict[str, Any] = field(default_factory=dict) @dataclass class UnitStatus: serial: str series: int monitoring: bool battery_volts: Optional[float] memory_total_bytes: Optional[int] memory_free_bytes: Optional[int] device_time: Optional[str] # ISO, the unit's own local time event_count: Optional[int] # None where it is not cheap (Series 3) detail: Dict[str, Any] = field(default_factory=dict) @dataclass class UnitSettings: serial: str series: int setup_name: Optional[str] record_mode: Optional[str] # the unit's own name for its mode sample_rate: Optional[int] record_time_s: Optional[float] histogram_interval_s: Optional[int] geo_trigger_ips: Optional[float] notes: Dict[str, str] = field(default_factory=dict) detail: Dict[str, Any] = field(default_factory=dict) ``` `sfm/device_access/__init__.py`: ```python """One door for every device request -- see the 2026-10-20 parity spec.""" from .errors import ( BadRequest, CallHomeInProgress, ConnectFailed, DeviceError, MalformedReply, NoAnswer, NotSupported, UnitBusy, WrongUnit, translate, ) from .models import UnitAddress, UnitInfo, UnitSettings, UnitStatus from .series import normalise_serial, series_for_serial ``` - [ ] **Step 4: Run the tests and watch them pass** Run: `.venv/bin/python -m pytest tests/test_device_access_core.py -q` Expected: all pass. - [ ] **Step 5: Commit** ```bash git add sfm/device_access/ tests/test_device_access_core.py git commit -m "feat(sfm): device_access core -- typed errors, series by serial prefix, shared models" -m "Co-Authored-By: Claude Opus 5.5 Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44" ``` --- ### Task 4: One connection per unit — the per-unit lock **Files:** - Create: `sfm/device_access/locks.py` - Test: `tests/test_device_access_core.py` (append) **Interfaces:** - Consumes: `UnitBusy` (Task 3). - Produces: `UnitLocks(timeout: float = 20.0)` with - `hold(key: str, timeout: Optional[float] = None)`, a context manager that raises `UnitBusy` on timeout; - `try_hold(key: str)`, a non-blocking context manager that yields `bool`. - [ ] **Step 1: Write the failing tests** Append to `tests/test_device_access_core.py`: ```python # ── per-unit lock ───────────────────────────────────────────────────────────── import threading # noqa: E402 from sfm.device_access.errors import UnitBusy # noqa: E402 from sfm.device_access.locks import UnitLocks # noqa: E402 def test_a_second_request_for_a_busy_unit_gets_unit_busy(): locks = UnitLocks(timeout=0.2) entered = threading.Event() release = threading.Event() def holder(): with locks.hold("tcp:10.0.0.5:9034"): entered.set() release.wait(2) t = threading.Thread(target=holder) t.start() entered.wait(2) try: with pytest.raises(UnitBusy, match="busy"): with locks.hold("tcp:10.0.0.5:9034"): pass finally: release.set() t.join() def test_different_units_do_not_block_each_other(): locks = UnitLocks(timeout=0.2) with locks.hold("tcp:10.0.0.5:9034"): with locks.hold("tcp:10.0.0.6:9034"): pass def test_try_hold_never_waits(): locks = UnitLocks(timeout=5) with locks.hold("k"): with locks.try_hold("k") as got: assert got is False with locks.try_hold("k") as got: assert got is True def test_the_lock_is_released_after_an_exception(): locks = UnitLocks(timeout=0.2) with pytest.raises(RuntimeError): with locks.hold("k"): raise RuntimeError("boom") with locks.hold("k"): pass ``` - [ ] **Step 2: Run the tests and watch them fail** Run: `.venv/bin/python -m pytest tests/test_device_access_core.py -q` Expected: collection ERROR, `ModuleNotFoundError: No module named 'sfm.device_access.locks'`. - [ ] **Step 3: Implement** `sfm/device_access/locks.py`: ```python """One connection per unit. A modem allows a single TCP session, so two requests must take turns instead of opening a second connection.""" from __future__ import annotations import threading from contextlib import contextmanager from typing import Dict, Iterator, Optional from .errors import UnitBusy class UnitLocks: def __init__(self, timeout: float = 20.0) -> None: self._timeout = timeout self._guard = threading.Lock() self._locks: Dict[str, threading.Lock] = {} def _lock_for(self, key: str) -> threading.Lock: with self._guard: return self._locks.setdefault(key, threading.Lock()) @contextmanager def hold(self, key: str, timeout: Optional[float] = None) -> Iterator[None]: lock = self._lock_for(key) wait = self._timeout if timeout is None else timeout if not lock.acquire(timeout=wait): raise UnitBusy(f"the unit at {key} is busy with another request; try again shortly") try: yield finally: lock.release() @contextmanager def try_hold(self, key: str) -> Iterator[bool]: lock = self._lock_for(key) got = lock.acquire(blocking=False) try: yield got finally: if got: lock.release() ``` Add to `sfm/device_access/__init__.py`: `from .locks import UnitLocks` - [ ] **Step 4: Run the tests and watch them pass** Run: `.venv/bin/python -m pytest tests/test_device_access_core.py -q` Expected: all pass. - [ ] **Step 5: Commit** ```bash git add sfm/device_access/locks.py sfm/device_access/__init__.py tests/test_device_access_core.py git commit -m "feat(sfm): per-unit lock -- one connection per unit, 423 when busy" -m "Co-Authored-By: Claude Opus 5.5 Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44" ``` --- ### Task 5: The Series-3 adapter Connect-per-request, as today. The TCP cold-boot retry-once from `server._run_with_retry` is kept, but **narrowed to "no answer"**, the cold-boot symptom. The legacy path retries any protocol error, which here would also retry the adapter's own "no settings block" error. When the serial is already in hand (`connect()` reads it), a mismatch is refused with 409. No extra round trip is added just to check it. **Files:** - Create: `sfm/device_access/s3.py`, `tests/device_access_fakes.py` - Test: `tests/test_device_access_s3.py` **Interfaces:** - Consumes: `UnitAddress`, `UnitInfo`, `UnitStatus`, `UnitSettings`, the errors and `translate` (Task 3). - Produces: - `Series3Adapter(client_factory: Callable[[UnitAddress], Any] = default_s3_client_factory)` with `identify(address, serial) -> UnitInfo`, `status(address, serial) -> UnitStatus` and `settings(address, serial) -> UnitSettings`. `serial` is already normalised. - `default_s3_client_factory(address, timeout=10.0) -> MiniMateClient`. - `tests/device_access_fakes.py`: `FakeMiniMateClient`, `FakeMicromateClient` (the latter is used from Task 6). - [ ] **Step 1: Write the test fakes** Create `tests/device_access_fakes.py`. These are test utilities, never imported by production code. They return the **real** model dataclasses, and the Micromate fake's setup comes from a real fixture read: ```python """Fakes of both device clients for sfm.device_access tests. They return the libraries' real dataclasses, and FakeMicromateClient's setup is decoded from a real UM20147 read. `fail` is a queue of exceptions; each call pops one, if any, and raises it. """ from __future__ import annotations import datetime from pathlib import Path from micromate.models import MicromateDeviceInfo, MicromateState from micromate.setup_block import decode_setup from minimateplus.models import ComplianceConfig, DeviceInfo, MonitorStatus SETUP_FIXTURE = Path(__file__).parent / "fixtures" / "micromate-setup" / "um20147_baseline.bin" class _Base: def __init__(self, fail=None, open_error=None): self.fail = list(fail or []) self.open_error = open_error self.calls: list[str] = [] self.opened = 0 self.closed = 0 self._open = False def _step(self, name): self.calls.append(name) if self.fail: raise self.fail.pop(0) def open(self): self.opened += 1 if self.open_error is not None: raise self.open_error self._open = True def close(self): self.closed += 1 self._open = False class FakeMiniMateClient(_Base): def __init__(self, serial="BE18193", *, monitoring=False, compliance="default", **kw): super().__init__(**kw) self.serial = serial self.monitoring = monitoring if compliance == "default": compliance = ComplianceConfig( recording_mode=0x01, sample_rate=1024, histogram_interval_sec=300, record_time=3.0, trigger_level_geo=0.5, alarm_level_geo=1.0, geo_range=0, setup_name="BRIDGE-A", project="Bridge job", client="Acme", operator="BH", sensor_location="Loc 1", notes=None, ) self.compliance = compliance def connect(self) -> DeviceInfo: self._step("connect") return DeviceInfo( serial=self.serial, firmware_minor=17, firmware_version="S338.17", dsp_version="10.72", manufacturer="Instantel", model="MiniMate Plus", compliance_config=self.compliance, ) def poll(self) -> None: self._step("poll") def get_monitor_status(self) -> MonitorStatus: self._step("get_monitor_status") return MonitorStatus( is_monitoring=self.monitoring, battery_v=6.8, memory_total=983026, memory_free=900000, ) class _FakeProtocol: def __init__(self, owner): self._owner = owner def poll(self): self._owner._step("poll") class FakeMicromateClient(_Base): def __init__(self, serial="UM20147", *, monitoring=False, events=5, unsolicited=b"", **kw): super().__init__(**kw) self.serial = serial self.monitoring = monitoring self.events = events self.unsolicited = unsolicited self.protocol = _FakeProtocol(self) def is_open(self) -> bool: return self._open def connect(self) -> MicromateDeviceInfo: self._step("connect") return MicromateDeviceInfo( serial=self.serial, manufacturer="Instantel", model="MM/ISEE/S", firmware_line="thor", monitoring=self.monitoring, active_setup="test2.MMB", ) def get_state(self) -> MicromateState: self._step("get_state") return MicromateState( monitoring=self.monitoring, device_time=datetime.datetime(2026, 10, 20, 18, 7, 58), battery_volts=3.8, memory_total_bytes=15_000_000, memory_free_bytes=14_799_296, ) def get_event_count(self) -> int: self._step("get_event_count") return self.events def get_setup(self): self._step("get_setup") return decode_setup(SETUP_FIXTURE.read_bytes()[11:]) def read_unsolicited(self) -> bytes: self._step("read_unsolicited") data, self.unsolicited = self.unsolicited, b"" return data ``` - [ ] **Step 2: Write the failing tests** Create `tests/test_device_access_s3.py`: ```python """The Series-3 adapter: connect-per-request, mapped into the shared models.""" from __future__ import annotations import os import sys import pytest sys.path.insert(0, os.path.dirname(os.path.dirname(os.path.abspath(__file__)))) import minimateplus.protocol as mmp_proto # noqa: E402 from device_access_fakes import FakeMiniMateClient # noqa: E402 from sfm.device_access.errors import ( # noqa: E402 ConnectFailed, MalformedReply, NoAnswer, WrongUnit, ) from sfm.device_access.models import UnitAddress # noqa: E402 from sfm.device_access.s3 import Series3Adapter # noqa: E402 TCP = UnitAddress(host="10.0.0.5", tcp_port=12345, port=None, baud=None) SERIAL_LINK = UnitAddress(host=None, tcp_port=None, port="/dev/ttyUSB0", baud=None) def adapter(*clients): queue = list(clients) return Series3Adapter(client_factory=lambda address: queue.pop(0)) def test_identify_maps_device_info(): fake = FakeMiniMateClient() info = adapter(fake).identify(TCP, "BE18193") assert (info.serial, info.series, info.model, info.firmware) == ("BE18193", 3, "MiniMate Plus", "S338.17") assert info.active_setup == "BRIDGE-A" assert info.monitoring is None # connect() does not read it on Series 3 assert fake.closed == 1 def test_a_different_unit_answering_is_refused(): fake = FakeMiniMateClient(serial="BE11529") with pytest.raises(WrongUnit, match="BE18193.*BE11529"): adapter(fake).identify(TCP, "BE18193") assert fake.closed == 1 def test_status_maps_monitor_status(): fake = FakeMiniMateClient(monitoring=True) st = adapter(fake).status(TCP, "BE18193") assert (st.series, st.monitoring, st.battery_volts) == (3, True, 6.8) assert (st.memory_total_bytes, st.memory_free_bytes) == (983026, 900000) assert st.event_count is None and st.device_time is None assert fake.calls == ["poll", "get_monitor_status"] def test_settings_maps_the_compliance_config(): s = adapter(FakeMiniMateClient()).settings(TCP, "BE18193") assert s.record_mode == "Continuous" assert (s.sample_rate, s.record_time_s, s.histogram_interval_s) == (1024, 3.0, 300) assert s.geo_trigger_ips == 0.5 assert s.setup_name == "BRIDGE-A" assert s.notes == {"Project": "Bridge job", "Client": "Acme", "User Name": "BH", "Seis Loc": "Loc 1"} assert s.detail["record_mode_code"] == 0x01 def test_settings_without_a_compliance_read_is_a_malformed_reply_and_not_retried(): # One fake only: a retry would ask the factory for a second and fail. with pytest.raises(MalformedReply, match="settings"): adapter(FakeMiniMateClient(compliance=None)).settings(TCP, "BE18193") def test_a_cold_unit_over_tcp_gets_one_retry(): first = FakeMiniMateClient(fail=[mmp_proto.TimeoutError("cold")]) second = FakeMiniMateClient() info = adapter(first, second).identify(TCP, "BE18193") assert info.serial == "BE18193" assert first.closed == 1 and second.closed == 1 def test_a_serial_link_is_not_retried(): fake = FakeMiniMateClient(fail=[mmp_proto.TimeoutError("quiet")]) with pytest.raises(NoAnswer): adapter(fake).identify(SERIAL_LINK, "BE18193") def test_a_failed_connect_is_connect_failed_and_not_retried(): fake = FakeMiniMateClient(open_error=ConnectionRefusedError("refused")) with pytest.raises(ConnectFailed, match="could not connect"): adapter(fake).identify(TCP, "BE18193") ``` - [ ] **Step 3: Run the tests and watch them fail** Run: `.venv/bin/python -m pytest tests/test_device_access_s3.py -q` Expected: collection ERROR, `ModuleNotFoundError: No module named 'sfm.device_access.s3'`. - [ ] **Step 4: Implement** `sfm/device_access/s3.py`: ```python """Series-3 adapter. Connect-per-request, as SFM has always done for MiniMates -- a held session waits for the bench test in the spec.""" from __future__ import annotations import logging from typing import Any, Callable from minimateplus import MiniMateClient from minimateplus.transport import TcpTransport from .errors import DeviceError, MalformedReply, NoAnswer, WrongUnit, translate from .models import UnitAddress, UnitInfo, UnitSettings, UnitStatus log = logging.getLogger("sfm.device_access") S3_DEFAULT_BAUD = 38400 S3_MODES = {0x00: "Single Shot", 0x01: "Continuous", 0x03: "Histogram", 0x04: "Histogram + Continuous"} def default_s3_client_factory(address: UnitAddress, timeout: float = 10.0) -> MiniMateClient: if address.host: return MiniMateClient(transport=TcpTransport(address.host, port=address.tcp_port), timeout=timeout) return MiniMateClient(address.port, address.baud or S3_DEFAULT_BAUD) def _close(client: Any) -> None: try: client.close() except Exception: # noqa: BLE001 log.debug("close failed", exc_info=True) class Series3Adapter: def __init__(self, client_factory: Callable[[UnitAddress], Any] = default_s3_client_factory) -> None: self._factory = client_factory def _run(self, address: UnitAddress, fn: Callable[[Any], Any]) -> Any: def attempt() -> Any: client = self._factory(address) try: client.open() except BaseException as exc: _close(client) raise translate(exc, connecting=True) from exc try: return fn(client) except DeviceError: raise except BaseException as exc: raise translate(exc, connecting=False) from exc finally: _close(client) try: return attempt() except NoAnswer: # A MiniMate that has just had its serial lines asserted can take # 5-10 s to boot, and shows it as silence; one retry covers it. TCP # only -- on a serial cable a silence is a real fault. Narrower than # server._run_with_retry (any protocol error): retrying a # MalformedReply would also retry "no settings block", which a # reconnect cannot fix. if not address.host: raise log.info("Series 3 at %s: no clean answer, retrying once (unit may be cold)", address.key) return attempt() @staticmethod def _check(serial_reported: str, serial: str, address: UnitAddress) -> None: if (serial_reported or "").strip().upper() != serial: raise WrongUnit(f"asked for {serial} but {serial_reported} answered at {address.key}") def identify(self, address: UnitAddress, serial: str) -> UnitInfo: def op(client: Any) -> UnitInfo: info = client.connect() self._check(info.serial, serial, address) cc = info.compliance_config return UnitInfo( serial=info.serial, series=3, model=info.model, firmware=info.firmware_version, monitoring=None, active_setup=cc.setup_name if cc else None, detail={"manufacturer": info.manufacturer, "dsp_version": info.dsp_version}, ) return self._run(address, op) def status(self, address: UnitAddress, serial: str) -> UnitStatus: def op(client: Any) -> UnitStatus: client.poll() ms = client.get_monitor_status() return UnitStatus( serial=serial, series=3, monitoring=ms.is_monitoring, battery_volts=round(ms.battery_v, 2) if ms.battery_v is not None else None, memory_total_bytes=ms.memory_total, memory_free_bytes=ms.memory_free, device_time=None, event_count=None, ) return self._run(address, op) def settings(self, address: UnitAddress, serial: str) -> UnitSettings: def op(client: Any) -> UnitSettings: info = client.connect() self._check(info.serial, serial, address) cc = info.compliance_config if cc is None: raise MalformedReply("could not read the unit's settings (SUB 0x1A)") mode = None if cc.recording_mode is not None: mode = S3_MODES.get(cc.recording_mode, f"unknown (0x{cc.recording_mode:02x})") notes = { label: value for label, value in ( ("Project", cc.project), ("Client", cc.client), ("User Name", cc.operator), ("Seis Loc", cc.sensor_location), ("Extended Notes", cc.notes), ) if value is not None } return UnitSettings( serial=info.serial, series=3, setup_name=cc.setup_name, record_mode=mode, sample_rate=cc.sample_rate, record_time_s=cc.record_time, histogram_interval_s=cc.histogram_interval_sec, geo_trigger_ips=cc.trigger_level_geo, notes=notes, detail={"record_mode_code": cc.recording_mode, "alarm_level_geo": cc.alarm_level_geo, "geo_range": cc.geo_range}, ) return self._run(address, op) ``` - [ ] **Step 5: Run the tests and watch them pass** Run: `.venv/bin/python -m pytest tests/test_device_access_s3.py -q` Expected: all pass. - [ ] **Step 6: Commit** ```bash git add sfm/device_access/s3.py tests/device_access_fakes.py tests/test_device_access_s3.py git commit -m "feat(sfm): Series-3 adapter -- identify, status, settings into the shared models" -m "Connect-per-request with the TCP cold-boot retry kept; a different unit answering is refused (409) whenever the serial is already in hand." -m "Co-Authored-By: Claude Opus 5.5 Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44" ``` --- ### Task 6: Series-4 session — stay on the line, ring safety **Files:** - Create: `sfm/device_access/s4.py` (session part) - Test: `tests/test_device_access_s4.py` **Interfaces:** - Consumes: errors and `translate`, `normalise_serial`, `UnitAddress` (Task 3); `MicromateClient.is_open()` (Task 1); `read_unsolicited()` (Task 2); `FakeMicromateClient` (Task 5). - Produces: - `RingDetected(Exception)`. - `RingWatchTransport(inner: BaseTransport)`, a `BaseTransport` whose `read()` raises `RingDetected` on `b"RADIO RING"`, including when it is split across reads. - `Series4Session(address, serial, client_factory, clock=time.monotonic)` with: - `call_up() -> MicromateDeviceInfo` (raises `WrongUnit` and `CallHomeInProgress`); - `run(op: Callable[[client], T]) -> T` (a user request; calls up first if needed); - `keepalive()`, which is a POLL and does not count as use; - `listen()`, which reads only and does not count as use; - `hang_up()`; - properties `is_open`, `last_used`, `last_traffic`. - `default_s4_client_factory(address, recv_timeout=10.0) -> MicromateClient`, with its transport wrapped in `RingWatchTransport`. - [ ] **Step 1: Write the failing tests** Create `tests/test_device_access_s4.py`: ```python """Series-4 sessions: one call-up, then stay on the line; ring safety.""" from __future__ import annotations import os import sys import pytest sys.path.insert(0, os.path.dirname(os.path.dirname(os.path.abspath(__file__)))) import micromate.protocol as mm_proto # noqa: E402 from device_access_fakes import FakeMicromateClient # noqa: E402 from sfm.device_access.errors import ( # noqa: E402 CallHomeInProgress, ConnectFailed, NoAnswer, WrongUnit, ) from sfm.device_access.models import UnitAddress # noqa: E402 from sfm.device_access.s4 import ( # noqa: E402 RingDetected, RingWatchTransport, Series4Session, ) ADDR = UnitAddress(host="10.0.0.5", tcp_port=9034, port=None, baud=None) class ScriptedInner: """A minimal real-interface transport: is_connected is a PROPERTY.""" def __init__(self, chunks): self.chunks = list(chunks) self.written = [] self._c = False def connect(self): self._c = True def disconnect(self): self._c = False @property def is_connected(self): return self._c def write(self, data): self.written.append(data) def read(self, n): return self.chunks.pop(0) if self.chunks else b"" class Clock: def __init__(self, t=1000.0): self.t = t def __call__(self): return self.t def session(*clients, clock=None): queue = list(clients) return Series4Session(ADDR, "UM20147", lambda address: queue.pop(0), clock=clock or Clock()) # ── RingWatchTransport ──────────────────────────────────────────────────────── def test_ordinary_bytes_pass_through(): t = RingWatchTransport(ScriptedInner([b"\x02abc\x03"])) assert t.read(4096) == b"\x02abc\x03" def test_a_ring_raises(): t = RingWatchTransport(ScriptedInner([b"\r\nRADIO RING\r\n"])) with pytest.raises(RingDetected): t.read(4096) def test_a_ring_split_across_reads_still_raises(): t = RingWatchTransport(ScriptedInner([b"\r\nRADIO R", b"ING\r\n"])) assert t.read(4096) == b"\r\nRADIO R" with pytest.raises(RingDetected): t.read(4096) def test_the_wrapper_keeps_is_connected_a_property(): inner = ScriptedInner([]) t = RingWatchTransport(inner) t.connect() assert t.is_connected is True # ── call-up ─────────────────────────────────────────────────────────────────── def test_call_up_verifies_the_serial_once(): fake = FakeMicromateClient() s = session(fake) s.run(lambda c: c.get_state()) s.run(lambda c: c.get_event_count()) assert fake.calls == ["connect", "get_state", "get_event_count"] assert fake.opened == 1 def test_a_different_unit_answering_is_refused_and_closed(): fake = FakeMicromateClient(serial="UM12947") s = session(fake) with pytest.raises(WrongUnit, match="UM20147.*UM12947"): s.run(lambda c: c.get_state()) assert fake.closed == 1 and not s.is_open assert fake.calls == ["connect"] # nothing after the identity check def test_a_failed_connect_is_connect_failed(): s = session(FakeMicromateClient(open_error=ConnectionRefusedError("no"))) with pytest.raises(ConnectFailed, match="could not connect"): s.run(lambda c: c.get_state()) # ── ring safety ─────────────────────────────────────────────────────────────── def test_a_ring_during_a_request_releases_the_line(): fake = FakeMicromateClient() s = session(fake) s.call_up() fake.fail = [RingDetected("RADIO RING")] with pytest.raises(CallHomeInProgress, match="calling home"): s.run(lambda c: c.get_state()) assert not s.is_open and fake.closed == 1 def test_listen_while_idle_releases_the_line_on_a_ring_and_sends_nothing(): fake = FakeMicromateClient() s = session(fake) s.call_up() fake.fail = [RingDetected("RADIO RING")] with pytest.raises(CallHomeInProgress): s.listen() assert not s.is_open assert fake.calls == ["connect", "read_unsolicited"] def test_the_next_request_after_a_ring_calls_up_fresh(): first, second = FakeMicromateClient(), FakeMicromateClient() s = session(first, second) s.call_up() first.fail = [RingDetected("RADIO RING")] with pytest.raises(CallHomeInProgress): s.run(lambda c: c.get_state()) s.run(lambda c: c.get_state()) assert second.calls == ["connect", "get_state"] # ── what counts as use ──────────────────────────────────────────────────────── def test_keepalive_and_listen_do_not_count_as_use(): clock = Clock(1000.0) fake = FakeMicromateClient() s = session(fake, clock=clock) s.call_up() clock.t = 1060.0 s.keepalive() clock.t = 1065.0 s.listen() assert s.last_used == 1000.0 assert s.last_traffic == 1060.0 assert fake.calls == ["connect", "poll", "read_unsolicited"] def test_a_request_counts_as_use(): clock = Clock(1000.0) s = session(FakeMicromateClient(), clock=clock) s.call_up() clock.t = 1100.0 s.run(lambda c: c.get_state()) assert s.last_used == 1100.0 and s.last_traffic == 1100.0 def test_a_failure_mid_request_hangs_up(): fake = FakeMicromateClient() s = session(fake) s.call_up() fake.fail = [mm_proto.TimeoutError("quiet")] with pytest.raises(NoAnswer): s.run(lambda c: c.get_state()) assert not s.is_open ``` - [ ] **Step 2: Run the tests and watch them fail** Run: `.venv/bin/python -m pytest tests/test_device_access_s4.py -q` Expected: collection ERROR, `ModuleNotFoundError: No module named 'sfm.device_access.s4'`. - [ ] **Step 3: Implement** `sfm/device_access/s4.py` (session part): ```python """Series-4 sessions: call up once, stay on the line, hang up when idle. ⚠ Imports only minimateplus.transport from the Series-3 package. Nothing here may build or send a Series-3 frame -- SESSION_RESET (41 03) has never been sent to a Micromate. """ from __future__ import annotations import logging import time from typing import Any, Callable, Optional, TypeVar from micromate.client import MicromateClient from minimateplus.transport import BaseTransport, SerialTransport, TcpTransport from .errors import CallHomeInProgress, WrongUnit, translate from .models import UnitAddress from .series import normalise_serial log = logging.getLogger("sfm.device_access") T = TypeVar("T") RING = b"RADIO RING" S4_DEFAULT_BAUD = 115200 class RingDetected(Exception): """The unit sent RADIO RING: it is calling home up this connection.""" class RingWatchTransport(BaseTransport): """Passes bytes through; raises RingDetected the moment RADIO RING appears, including when it is split across two reads.""" def __init__(self, inner: BaseTransport) -> None: self._inner = inner self._tail = b"" def connect(self) -> None: self._inner.connect() def disconnect(self) -> None: self._inner.disconnect() @property def is_connected(self) -> bool: return self._inner.is_connected def write(self, data: bytes) -> None: self._inner.write(data) def read(self, n: int) -> bytes: data = self._inner.read(n) if data: window = self._tail + data if RING in window: self._tail = b"" raise RingDetected("RADIO RING") self._tail = window[-(len(RING) - 1):] return data def default_s4_client_factory(address: UnitAddress, recv_timeout: float = 10.0) -> MicromateClient: if address.host: inner: BaseTransport = TcpTransport(address.host, port=address.tcp_port) else: inner = SerialTransport(address.port, address.baud or S4_DEFAULT_BAUD) return MicromateClient(RingWatchTransport(inner), recv_timeout=recv_timeout) def _close(client: Any) -> None: try: client.close() except Exception: # noqa: BLE001 log.debug("close failed", exc_info=True) _RING_MESSAGE = ("the unit started calling home; SFM hung up so the call can " "reach THOR -- try again in a few minutes") class Series4Session: """One held line to one Micromate. `last_used` is the last *user* request: the idle hang-up measures it. `last_traffic` is any exchange, keep-alives included: the keep-alive schedule measures it. If keep-alives counted as use, the line would never go idle. """ def __init__(self, address: UnitAddress, serial: str, client_factory: Callable[[UnitAddress], Any], clock: Callable[[], float] = time.monotonic) -> None: self.address = address self.serial = normalise_serial(serial) self._factory = client_factory self._clock = clock self._client: Optional[Any] = None self.info = None self.last_used = clock() self.last_traffic = self.last_used @property def is_open(self) -> bool: return self._client is not None and self._client.is_open() def call_up(self): client = self._factory(self.address) try: client.open() info = client.connect() except RingDetected as exc: _close(client) log.warning("RADIO RING from %s during call-up -- released the line", self.address.key) raise CallHomeInProgress(_RING_MESSAGE) from exc except BaseException as exc: _close(client) raise translate(exc, connecting=True) from exc if normalise_serial(info.serial) != self.serial: _close(client) raise WrongUnit(f"asked for {self.serial} but {info.serial} answered at {self.address.key}") self._client, self.info = client, info self.last_used = self.last_traffic = self._clock() log.info("call-up: %s at %s, staying on the line", self.serial, self.address.key) return info def _exchange(self, op: Callable[[Any], T]) -> T: try: return op(self._client) except RingDetected as exc: self.hang_up() log.warning("RADIO RING from %s -- released the line so the call reaches THOR", self.address.key) raise CallHomeInProgress(_RING_MESSAGE) from exc except BaseException as exc: self.hang_up() raise translate(exc, connecting=False) from exc def run(self, op: Callable[[Any], T]) -> T: """A user request. Calls up first if the line is not open.""" if not self.is_open: self.call_up() result = self._exchange(op) self.last_used = self.last_traffic = self._clock() return result def keepalive(self) -> None: """A POLL so the modem's idle timer does not drop the line. Not use.""" if not self.is_open: return self._exchange(lambda c: c.protocol.poll()) self.last_traffic = self._clock() def listen(self) -> None: """Read anything the unit sent unprompted; send nothing. Not use.""" if not self.is_open: return self._exchange(lambda c: c.read_unsolicited()) def hang_up(self) -> None: if self._client is not None: _close(self._client) self._client = None log.info("hang-up: %s at %s", self.serial, self.address.key) ``` - [ ] **Step 4: Run the tests and watch them pass** Run: `.venv/bin/python -m pytest tests/test_device_access_s4.py -q` Expected: all pass. - [ ] **Step 5: Commit** ```bash git add sfm/device_access/s4.py tests/test_device_access_s4.py git commit -m "feat(sfm): Series-4 session -- call up once, stay on the line, release on RADIO RING" -m "Co-Authored-By: Claude Opus 5.5 Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44" ``` --- ### Task 7: Series-4 operations — identify, status, settings **Files:** - Modify: `sfm/device_access/s4.py` (append) - Test: `tests/test_device_access_s4.py` (append) **Interfaces:** - Consumes: `UnitInfo`, `UnitStatus`, `UnitSettings` (Task 3); client methods from Tasks 1 and 2 and `get_setup()`. - Produces, each run inside `Series4Session.run`: - `s4_identify(client, serial: str) -> UnitInfo` - `s4_status(client, serial: str) -> UnitStatus` - `s4_settings(client, serial: str) -> UnitSettings` - [ ] **Step 1: Write the failing tests** Append to `tests/test_device_access_s4.py`. The settings values are what the operator read off UM20147's screen for `um20147_baseline` (see `tests/test_micromate_setup.py`): ```python # ── operations ──────────────────────────────────────────────────────────────── from sfm.device_access.s4 import s4_identify, s4_settings, s4_status # noqa: E402 def test_s4_identify(): info = s4_identify(FakeMicromateClient(monitoring=True), "UM20147") assert (info.serial, info.series, info.model, info.monitoring) == ("UM20147", 4, "MM/ISEE/S", True) assert info.active_setup == "test2.MMB" assert info.firmware is None and info.detail["firmware_line"] == "thor" def test_s4_status_includes_the_cheap_event_count(): st = s4_status(FakeMicromateClient(events=5), "UM20147") assert (st.series, st.monitoring, st.battery_volts, st.event_count) == (4, False, 3.8, 5) assert (st.memory_total_bytes, st.memory_free_bytes) == (15_000_000, 14_799_296) assert st.device_time == "2026-10-20T18:07:58" def test_s4_settings_maps_the_decoded_setup(): s = s4_settings(FakeMicromateClient(), "UM20147") assert (s.series, s.setup_name, s.record_mode) == (4, "test2.MMB", "Histogram Combo") assert (s.sample_rate, s.record_time_s, s.histogram_interval_s) == (1024, 10.0, 2) assert s.geo_trigger_ips == pytest.approx(0.5, abs=1e-6) assert list(s.notes) == ["Location", "Client", "Company", "General Notes"] assert s.detail["pretrigger_s"] == 1.0 assert s.detail["mic_type"] == "linear" assert s.detail["mic_trigger_db"] == pytest.approx(131.0, abs=0.01) assert s.detail["geo_trigger_ips_per_channel"] == pytest.approx([0.5, 0.5, 0.5], abs=1e-6) ``` - [ ] **Step 2: Run the tests and watch them fail** Run: `.venv/bin/python -m pytest tests/test_device_access_s4.py -q` Expected: collection ERROR, `ImportError: cannot import name 's4_identify'`. - [ ] **Step 3: Implement** Append to `sfm/device_access/s4.py`, and add `UnitInfo, UnitSettings, UnitStatus` to its `.models` import: ```python # ── Operations (each runs inside Series4Session.run) ────────────────────────── def s4_identify(client: Any, serial: str) -> UnitInfo: info = client.connect() return UnitInfo( serial=info.serial, series=4, model=info.model, firmware=None, # the version string lives in 0x01, undecoded monitoring=info.monitoring, active_setup=info.active_setup, detail={"manufacturer": info.manufacturer, "firmware_line": info.firmware_line}, ) def s4_status(client: Any, serial: str) -> UnitStatus: st = client.get_state() count = client.get_event_count() return UnitStatus( serial=serial, series=4, monitoring=st.monitoring, battery_volts=st.battery_volts, memory_total_bytes=st.memory_total_bytes, memory_free_bytes=st.memory_free_bytes, device_time=st.device_time.isoformat() if st.device_time else None, event_count=count, ) def s4_settings(client: Any, serial: str) -> UnitSettings: s = client.get_setup() return UnitSettings( serial=serial, series=4, setup_name=s.name, record_mode=s.record_mode_name, sample_rate=s.sample_rate, record_time_s=s.record_time_s, histogram_interval_s=s.histogram_interval_s, geo_trigger_ips=s.geo_trigger_ips[0], # the keypad writes all three the same notes=dict(s.notes), detail={ "pretrigger_s": s.pretrigger_s, "auto_record_stop": s.auto_record_stop, "auto_stop_after_s": s.auto_stop_after_s, "geophones_active": s.geophones_active, "mic_active": s.mic_active, "trigger_on_geophones": s.trigger_on_geophones, "trigger_on_mic": s.trigger_on_mic, "geo_trigger_ips_per_channel": list(s.geo_trigger_ips), "mic_type": s.mic_type, "mic_trigger_psi": s.mic_trigger_psi, "mic_trigger_db": s.mic_trigger_db, "job_number_enabled": s.job_number_enabled, "job_number": s.job_number, "scaled_distance_enabled": s.scaled_distance_enabled, "distance_ft": s.distance_ft, "charge_weight_lb": s.charge_weight_lb, "scaled_distance": s.scaled_distance, }, ) ``` - [ ] **Step 4: Run the tests and watch them pass** Run: `.venv/bin/python -m pytest tests/test_device_access_s4.py -q` Expected: all pass. - [ ] **Step 5: Commit** ```bash git add sfm/device_access/s4.py tests/test_device_access_s4.py git commit -m "feat(sfm): Series-4 identify, status and settings into the shared models" -m "Co-Authored-By: Claude Opus 5.5 Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44" ``` --- ### Task 8: `DeviceAccess` — one door, sessions, the reaper **Files:** - Create: `sfm/device_access/access.py` - Test: `tests/test_device_access.py` **Interfaces:** - Consumes: everything from Tasks 3–7. - Produces: `DeviceAccess(*, s3_client_factory=default_s3_client_factory, s4_client_factory=default_s4_client_factory, clock=time.monotonic, lock_timeout=20.0, keepalive_s=60.0, idle_hangup_s=300.0, reaper_interval_s=5.0, start_reaper=True)` with: - `identify(address: UnitAddress, serial: str) -> UnitInfo` - `status(address, serial) -> UnitStatus` - `settings(address, serial) -> UnitSettings` - `hang_up(address) -> bool`, True if a held line was closed - `tick(now: Optional[float] = None) -> None`, for tests; the reaper thread calls it. - [ ] **Step 1: Write the failing tests** Create `tests/test_device_access.py`: ```python """DeviceAccess: dispatch by serial, sessions, the lock, the reaper -- and the contract that both series answer in the same shape.""" from __future__ import annotations import dataclasses import os import sys import threading import pytest sys.path.insert(0, os.path.dirname(os.path.dirname(os.path.abspath(__file__)))) from device_access_fakes import FakeMiniMateClient, FakeMicromateClient # noqa: E402 from sfm.device_access.access import DeviceAccess # noqa: E402 from sfm.device_access.errors import BadRequest, CallHomeInProgress, UnitBusy # noqa: E402 from sfm.device_access.models import UnitAddress # noqa: E402 from sfm.device_access.s4 import RingDetected # noqa: E402 ADDR = UnitAddress(host="10.0.0.5", tcp_port=9034, port=None, baud=None) class Clock: def __init__(self, t=1000.0): self.t = t def __call__(self): return self.t def access(s3=(), s4=(), clock=None, lock_timeout=0.2): s3q, s4q = list(s3), list(s4) return DeviceAccess( s3_client_factory=lambda a: s3q.pop(0), s4_client_factory=lambda a: s4q.pop(0), clock=clock or Clock(), lock_timeout=lock_timeout, start_reaper=False, ) def test_the_serial_prefix_picks_the_adapter(): da = access(s3=[FakeMiniMateClient()], s4=[FakeMicromateClient()]) assert da.identify(ADDR, "be18193").series == 3 assert da.identify(ADDR, " um20147").series == 4 def test_an_unknown_prefix_never_touches_a_unit(): da = access() with pytest.raises(BadRequest): da.identify(ADDR, "XX123") def test_a_micromate_stays_on_the_line_between_requests(): fake = FakeMicromateClient() da = access(s4=[fake]) da.identify(ADDR, "UM20147") da.status(ADDR, "UM20147") da.settings(ADDR, "UM20147") assert fake.opened == 1 # one call-up, three requests assert fake.calls[0] == "connect" def test_a_minimate_reconnects_per_request(): a, b = FakeMiniMateClient(), FakeMiniMateClient() da = access(s3=[a, b]) da.status(ADDR, "BE18193") da.status(ADDR, "BE18193") assert a.closed == 1 and b.closed == 1 def test_a_dropped_line_is_called_up_again_quietly(): first, second = FakeMicromateClient(), FakeMicromateClient() da = access(s4=[first, second]) da.status(ADDR, "UM20147") first._open = False # the modem dropped the idle line st = da.status(ADDR, "UM20147") assert st.series == 4 and second.opened == 1 def test_a_different_serial_at_the_same_address_hangs_up_the_old_line(): first, second = FakeMicromateClient(), FakeMicromateClient(serial="UM12947") da = access(s4=[first, second]) da.status(ADDR, "UM20147") da.status(ADDR, "UM12947") assert first.closed == 1 and second.opened == 1 def test_a_busy_unit_answers_423_without_a_second_connection(): fake = FakeMicromateClient() da = access(s4=[fake], lock_timeout=0.2) entered, release = threading.Event(), threading.Event() def slow_request(): with da._locks.hold(ADDR.key): # simulate a request in flight entered.set() release.wait(2) t = threading.Thread(target=slow_request) t.start() entered.wait(2) try: with pytest.raises(UnitBusy): da.status(ADDR, "UM20147") assert fake.opened == 0 # no second connection was opened finally: release.set() t.join() def test_hang_up_closes_a_held_line(): fake = FakeMicromateClient() da = access(s4=[fake]) da.status(ADDR, "UM20147") assert da.hang_up(ADDR) is True assert fake.closed == 1 assert da.hang_up(ADDR) is False # nothing left to hang up # ── the reaper ──────────────────────────────────────────────────────────────── def test_tick_listens_then_keeps_alive_then_hangs_up_when_idle(): clock = Clock(1000.0) fake = FakeMicromateClient() da = access(s4=[fake], clock=clock) da.status(ADDR, "UM20147") fake.calls.clear() clock.t = 1030.0 da.tick() # quiet: listen only assert fake.calls == ["read_unsolicited"] clock.t = 1061.0 da.tick() # 60 s since traffic: keep-alive assert fake.calls[-1] == "poll" clock.t = 1301.0 da.tick() # 300 s since last USE: hang up assert fake.closed == 1 assert da.hang_up(ADDR) is False def test_tick_releases_the_line_on_a_ring_while_idle(): clock = Clock(1000.0) fake = FakeMicromateClient() da = access(s4=[fake], clock=clock) da.status(ADDR, "UM20147") fake.fail = [RingDetected("RADIO RING")] clock.t = 1010.0 da.tick() assert fake.closed == 1 def test_tick_skips_a_unit_that_is_busy(): clock = Clock(1000.0) fake = FakeMicromateClient() da = access(s4=[fake], clock=clock) da.status(ADDR, "UM20147") fake.calls.clear() clock.t = 1400.0 with da._locks.hold(ADDR.key): da.tick() # must not block or hang up mid-request assert fake.calls == [] and fake.closed == 0 def test_a_ring_mid_request_is_a_clear_error(): fake = FakeMicromateClient() da = access(s4=[fake]) da.status(ADDR, "UM20147") fake.fail = [RingDetected("RADIO RING")] with pytest.raises(CallHomeInProgress): da.status(ADDR, "UM20147") # ── the contract: both series answer in the same shape ──────────────────────── @pytest.mark.parametrize("op", ["identify", "status", "settings"]) def test_both_series_return_the_same_model_with_the_same_fields(op): da = access(s3=[FakeMiniMateClient()], s4=[FakeMicromateClient()]) s3 = getattr(da, op)(ADDR, "BE18193") s4 = getattr(da, op)(ADDR, "UM20147") assert type(s3) is type(s4) assert [f.name for f in dataclasses.fields(s3)] == [f.name for f in dataclasses.fields(s4)] assert (s3.series, s4.series) == (3, 4) for name in (f.name for f in dataclasses.fields(s3)): a, b = getattr(s3, name), getattr(s4, name) if a is not None and b is not None and name != "detail": assert type(a) is type(b) or {type(a), type(b)} <= {int, float}, name ``` - [ ] **Step 2: Run the tests and watch them fail** Run: `.venv/bin/python -m pytest tests/test_device_access.py -q` Expected: collection ERROR, `ModuleNotFoundError: No module named 'sfm.device_access.access'`. - [ ] **Step 3: Implement** `sfm/device_access/access.py`: ```python """DeviceAccess -- the one door every device request passes through. The control surface does not care which series it is talking to; this does. """ from __future__ import annotations import logging import threading import time from typing import Any, Callable, Dict, Optional from .errors import DeviceError from .locks import UnitLocks from .models import UnitAddress, UnitInfo, UnitSettings, UnitStatus from .s3 import Series3Adapter, default_s3_client_factory from .s4 import ( Series4Session, default_s4_client_factory, s4_identify, s4_settings, s4_status, ) from .series import normalise_serial, series_for_serial log = logging.getLogger("sfm.device_access") class DeviceAccess: def __init__( self, *, s3_client_factory: Callable[[UnitAddress], Any] = default_s3_client_factory, s4_client_factory: Callable[[UnitAddress], Any] = default_s4_client_factory, clock: Callable[[], float] = time.monotonic, lock_timeout: float = 20.0, keepalive_s: float = 60.0, idle_hangup_s: float = 300.0, reaper_interval_s: float = 5.0, start_reaper: bool = True, ) -> None: self._locks = UnitLocks(lock_timeout) self._s3 = Series3Adapter(s3_client_factory) self._s4_factory = s4_client_factory self._clock = clock self._keepalive_s = keepalive_s self._idle_hangup_s = idle_hangup_s self._reaper_interval_s = reaper_interval_s self._start_reaper = start_reaper self._reaper: Optional[threading.Thread] = None self._sessions: Dict[str, Series4Session] = {} self._sessions_guard = threading.Lock() # ── public operations ───────────────────────────────────────────────────── def identify(self, address: UnitAddress, serial: str) -> UnitInfo: return self._dispatch(address, serial, self._s3.identify, s4_identify) def status(self, address: UnitAddress, serial: str) -> UnitStatus: return self._dispatch(address, serial, self._s3.status, s4_status) def settings(self, address: UnitAddress, serial: str) -> UnitSettings: return self._dispatch(address, serial, self._s3.settings, s4_settings) def hang_up(self, address: UnitAddress) -> bool: with self._locks.hold(address.key): with self._sessions_guard: session = self._sessions.pop(address.key, None) if session is None: return False was_open = session.is_open session.hang_up() return was_open # ── dispatch ────────────────────────────────────────────────────────────── def _dispatch(self, address: UnitAddress, serial: str, s3_op: Callable[[UnitAddress, str], Any], s4_op: Callable[[Any, str], Any]) -> Any: serial = normalise_serial(serial) series = series_for_serial(serial) # raises BadRequest before any I/O with self._locks.hold(address.key): if series == 3: return s3_op(address, serial) session = self._session_for(address, serial) try: return session.run(lambda client: s4_op(client, serial)) except DeviceError: if not session.is_open: with self._sessions_guard: if self._sessions.get(address.key) is session: del self._sessions[address.key] raise def _session_for(self, address: UnitAddress, serial: str) -> Series4Session: with self._sessions_guard: session = self._sessions.get(address.key) if session is not None and session.serial != serial: session.hang_up() session = None if session is None: session = Series4Session(address, serial, self._s4_factory, clock=self._clock) self._sessions[address.key] = session self._ensure_reaper() return session # ── the reaper ──────────────────────────────────────────────────────────── def tick(self, now: Optional[float] = None) -> None: """Per held line: hang up if idle, else keep alive, else listen for a ring.""" now = self._clock() if now is None else now with self._sessions_guard: items = list(self._sessions.items()) for key, session in items: with self._locks.try_hold(key) as held: if not held: continue # mid-request: not idle if not session.is_open: self._drop(key, session) continue try: if now - session.last_used >= self._idle_hangup_s: session.hang_up() self._drop(key, session) elif now - session.last_traffic >= self._keepalive_s: session.keepalive() else: session.listen() except DeviceError as exc: log.warning("held line %s closed: %s", key, exc) self._drop(key, session) def _drop(self, key: str, session: Series4Session) -> None: with self._sessions_guard: if self._sessions.get(key) is session: del self._sessions[key] def _ensure_reaper(self) -> None: if not self._start_reaper or self._reaper is not None: return self._reaper = threading.Thread(target=self._reaper_loop, name="sfm-held-lines", daemon=True) self._reaper.start() def _reaper_loop(self) -> None: while True: time.sleep(self._reaper_interval_s) try: self.tick() except Exception: # noqa: BLE001 log.exception("held-line reaper tick failed") ``` Add to `sfm/device_access/__init__.py`: `from .access import DeviceAccess` - [ ] **Step 4: Run the tests and watch them pass** Run: `.venv/bin/python -m pytest tests/test_device_access*.py -q` Expected: all pass. - [ ] **Step 5: Commit** ```bash git add sfm/device_access/access.py sfm/device_access/__init__.py tests/test_device_access.py git commit -m "feat(sfm): DeviceAccess -- one door, held Series-4 lines, a reaper, and the same answer shape for both series" -m "Co-Authored-By: Claude Opus 5.5 Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44" ``` --- ### Task 9: The endpoints `serial` routes a request through `DeviceAccess`. Without it, every handler runs exactly as today. **Files:** - Modify: `sfm/server.py`: - imports; - module docstring; - `device_info` (~line 405), `device_connect` (~line 460) and `device_monitor_status` (~line 1100); - two new handlers after `device_monitor_status`. - Test: `tests/test_server_device_access.py` **Interfaces:** - Consumes: `DeviceAccess`, `UnitAddress`, `DeviceError` (Tasks 3, 8). - Produces: - query parameter `serial` on `GET /device/info`, `POST /device/connect` and `GET /device/monitor/status`; - `GET /device/settings` (`serial` required); - `POST /device/hangup`; - module-level `_device_access() -> DeviceAccess` and the `_device_access_instance` singleton, so tests can monkeypatch them. - [ ] **Step 1: Write the failing tests** Create `tests/test_server_device_access.py`: ```python """Handlers called directly -- every parameter passed explicitly, because FastAPI Query() defaults are FieldInfo objects, not values.""" from __future__ import annotations import os import sys import pytest sys.path.insert(0, os.path.dirname(os.path.dirname(os.path.abspath(__file__)))) from fastapi import HTTPException # noqa: E402 import sfm.server as srv # noqa: E402 from device_access_fakes import FakeMiniMateClient, FakeMicromateClient # noqa: E402 from sfm.device_access.access import DeviceAccess # noqa: E402 from sfm.device_access.errors import ( # noqa: E402 BadRequest, CallHomeInProgress, ConnectFailed, MalformedReply, NoAnswer, NotSupported, UnitBusy, WrongUnit, ) TCP = dict(port=None, baud=None, host="10.0.0.5", tcp_port=9034) @pytest.fixture def da(monkeypatch): s3q = [FakeMiniMateClient() for _ in range(5)] s4q = [FakeMicromateClient() for _ in range(5)] access = DeviceAccess(s3_client_factory=lambda a: s3q.pop(0), s4_client_factory=lambda a: s4q.pop(0), start_reaper=False) monkeypatch.setattr(srv, "_device_access_instance", access) return access def test_info_with_a_serial_returns_the_shared_model(da): out = srv.device_info(force=False, serial="UM20147", **TCP) assert out["series"] == 4 and out["serial"] == "UM20147" assert set(out) == {"serial", "series", "model", "firmware", "monitoring", "active_setup", "detail"} def test_connect_passes_the_serial_through(da): out = srv.device_connect(serial="BE18193", **TCP) assert out["series"] == 3 def test_status_and_settings_with_a_serial(da): assert srv.device_monitor_status(force=False, serial="UM20147", **TCP)["event_count"] == 5 assert srv.device_settings(serial="UM20147", **TCP)["record_mode"] == "Histogram Combo" def test_hangup(da): srv.device_monitor_status(force=False, serial="UM20147", **TCP) assert srv.device_hangup(**TCP) == {"hung_up": True} @pytest.mark.parametrize( "exc, status", [(BadRequest("x"), 422), (NotSupported("x"), 501), (WrongUnit("x"), 409), (UnitBusy("x"), 423), (ConnectFailed("x"), 503), (CallHomeInProgress("x"), 503), (NoAnswer("x"), 504), (MalformedReply("x"), 502)], ) def test_typed_errors_become_their_http_status(monkeypatch, exc, status): class Raising: def identify(self, address, serial): raise exc monkeypatch.setattr(srv, "_device_access_instance", Raising()) with pytest.raises(HTTPException) as ei: srv.device_info(force=False, serial="UM20147", **TCP) assert ei.value.status_code == status def test_a_missing_address_is_a_422(da): with pytest.raises(HTTPException) as ei: srv.device_settings(serial="UM20147", port=None, baud=None, host=None, tcp_port=9034) assert ei.value.status_code == 422 def test_without_a_serial_the_legacy_path_runs_unchanged(monkeypatch): """No serial: today's Series-3 code path, today's response shape. DeviceAccess must not be touched.""" class Untouchable: def __getattr__(self, name): raise AssertionError("DeviceAccess used on the legacy path") class Cache: def get_device_info(self, key): return {"serial": "BE18193", "firmware_version": "S338.17"} monkeypatch.setattr(srv, "_device_access_instance", Untouchable()) monkeypatch.setattr(srv, "get_cache", lambda: Cache()) out = srv.device_info(force=False, serial=None, **TCP) assert out == {"serial": "BE18193", "firmware_version": "S338.17", "_cached": True} ``` - [ ] **Step 2: Run the tests and watch them fail** Run: `.venv/bin/python -m pytest tests/test_server_device_access.py -q` Expected: FAIL. `device_info() got an unexpected keyword argument 'serial'`, and `module 'sfm.server' has no attribute 'device_settings'`. - [ ] **Step 3: Implement** In `sfm/server.py`, after the existing `from sfm import db_snapshot` import: ```python import dataclasses from sfm.device_access import DeviceAccess, DeviceError, UnitAddress ``` After `_run_with_retry` (the "Transport factory" section): ```python # ── Device access (serial-named requests) ───────────────────────────────────── # A request that names the unit by `serial` goes through sfm.device_access: # same contract for Series 3 and 4. Without `serial`, handlers run their # legacy Series-3 path unchanged (spec 2026-10-20). _device_access_instance: Optional[DeviceAccess] = None def _device_access() -> DeviceAccess: global _device_access_instance if _device_access_instance is None: _device_access_instance = DeviceAccess() return _device_access_instance def _unit_address(port: Optional[str], baud: Optional[int], host: Optional[str], tcp_port: int) -> UnitAddress: return UnitAddress(host=host, tcp_port=tcp_port if host else None, port=None if host else port, baud=baud) def _via_device_access(fn) -> dict: try: result = fn() except DeviceError as exc: raise HTTPException(status_code=exc.http_status, detail=str(exc)) from exc return dataclasses.asdict(result) if dataclasses.is_dataclass(result) else result _SERIAL_DOC = "Unit serial -- UM... (Series 4) or BE.../BA... (Series 3). Returns the shared model." ``` `device_info`: - change `baud: int = Query(38400, ...)` to `baud: Optional[int] = Query(None, description="Serial baud (default 38400; 115200 for a Micromate)")`; - add `serial: Optional[str] = Query(None, description=_SERIAL_DOC)` as the last parameter; - make these the first lines of the body, before the existing `log.info`: ```python if serial: return _via_device_access( lambda: _device_access().identify(_unit_address(port, baud, host, tcp_port), serial)) baud = 38400 if baud is None else baud ``` `device_connect`: the same `baud` change, add the same `serial` parameter, and replace its body with: ```python # force=True PRESERVES today's behaviour: the old call omitted `force`, so it # received FastAPI's Query(False) object, which is truthy -- /device/connect # has always bypassed the cache. Passing False here would quietly change that. return device_info(port=port, baud=baud, host=host, tcp_port=tcp_port, force=True, serial=serial) ``` `device_monitor_status`: the same `baud` change, add `serial` as the last parameter, and make these the first lines of the body: ```python if serial: return _via_device_access( lambda: _device_access().status(_unit_address(port, baud, host, tcp_port), serial)) baud = 38400 if baud is None else baud ``` Add after `device_monitor_status`: ```python @app.get("/device/settings") def device_settings( serial: str = Query(..., description=_SERIAL_DOC), port: Optional[str] = Query(None, description="Serial port (e.g. /dev/ttyACM0)"), baud: Optional[int] = Query(None, description="Serial baud (default by series)"), host: Optional[str] = Query(None, description="TCP host -- modem IP"), tcp_port: int = Query(DEFAULT_TCP_PORT, description=f"TCP port (default {DEFAULT_TCP_PORT})"), ) -> dict: """The unit's recording settings, in the shared shape for either series.""" return _via_device_access( lambda: _device_access().settings(_unit_address(port, baud, host, tcp_port), serial)) @app.post("/device/hangup") def device_hangup( port: Optional[str] = Query(None, description="Serial port"), baud: Optional[int] = Query(None, description="Serial baud"), host: Optional[str] = Query(None, description="TCP host -- modem IP"), tcp_port: int = Query(DEFAULT_TCP_PORT, description=f"TCP port (default {DEFAULT_TCP_PORT})"), ) -> dict: """Hang up a held line now instead of waiting for the idle timeout. `hung_up` is false if nothing was being held.""" return _via_device_access( lambda: {"hung_up": _device_access().hang_up(_unit_address(port, baud, host, tcp_port))}) ``` In the module docstring's endpoint list, add: ``` GET /device/settings Recording settings (requires serial) POST /device/hangup Hang up a held Series-4 line `serial` on /device/info, /device/connect, /device/monitor/status and /device/settings names the unit (UM... = Series 4, BE.../BA... = Series 3) and returns the shared model. Without it, the legacy Series-3 behaviour is unchanged. Series-4 lines are held open between requests and hung up after 5 idle minutes, on POST /device/hangup, or the moment the unit calls home. ``` - [ ] **Step 4: Run the tests and watch them pass** Run: `.venv/bin/python -m pytest tests/test_server_device_access.py -q` Expected: all pass. - [ ] **Step 5: Run the full suite** Run: `.venv/bin/python -m pytest tests -q` Expected: the baseline plus the new tests. Still exactly **16 failed**, the same two files (`test_bw_ascii_report.py` 15, `test_event_file_io.py` 1). More passed. - [ ] **Step 6: Commit** ```bash git add sfm/server.py tests/test_server_device_access.py git commit -m "feat(sfm): serial-named /device/info, /status, /settings and /hangup for both series" -m "With serial: one contract for Series 3 and 4 through sfm.device_access. Without it: the legacy Series-3 path, unchanged." -m "Co-Authored-By: Claude Opus 5.5 Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44" ``` --- ### Task 10: Bench check on UM20147, and the record Read-only, on the real unit, through the real server. **Files:** - Modify: `CLAUDE.md` (the Series-4 config bullet in "Where things stand") - [ ] **Step 1: Start SFM with access to the unit's port** ```bash sg dialout -c ".venv/bin/python -m uvicorn sfm.server:app --port 8299" & sleep 3 ``` - [ ] **Step 2: Identify, status, settings by serial, then hang up** ```bash Q="port=/dev/ttyACM0&serial=UM20147" curl -s "localhost:8299/device/info?$Q" | python3 -m json.tool curl -s "localhost:8299/device/monitor/status?$Q" | python3 -m json.tool curl -s "localhost:8299/device/settings?$Q" | python3 -m json.tool curl -s -X POST "localhost:8299/device/hangup?port=/dev/ttyACM0" ; echo ``` Expected: - `series: 4`, `serial: "UM20147"`. - The settings match `bridges/mm_client_check.py`'s output and the unit's screen. On 2026-10-20: Histogram Combo, 2048 sps, record time 11 s, pre-trigger 0.25 s, geophone trigger 0.6 in/s, mic 140 dB, job number 1234 (off), Location BENCH01. - `event_count` equals the chain-walk count from Task 2. - The server log shows **one** call-up for the three requests, then a hang-up. - The hang-up response is `{"hung_up": true}`. - [ ] **Step 3: Ask for the wrong serial** ```bash curl -s -w "\n%{http_code}\n" "localhost:8299/device/info?port=/dev/ttyACM0&serial=UM12947" ``` Expected: `409`, with "asked for UM12947 but UM20147 answered". - [ ] **Step 4: Stop the server** ```bash kill %1 ``` - [ ] **Step 5: Record it in CLAUDE.md** In "Where things stand", in the Series-4 config bullet, add this after the `get_setup()` line: ``` ✅ **SFM speaks Series 4 by serial (phase 1a, 2026-10-20):** `/device/info`, `/device/monitor/status` and `/device/settings` take `serial` and return one shared shape for both series through `sfm/device_access/`. Micromate lines are held open (one call-up, keep-alive 60 s, idle hang-up 5 min, released on RADIO RING); MiniMates still reconnect per request. Without `serial` the legacy Series-3 path is unchanged. Next: 1b (events), 1c (webapp). ``` - [ ] **Step 6: Commit** ```bash git add CLAUDE.md git commit -m "docs(claude): SFM speaks Series 4 by serial -- phase 1a done, bench-checked on UM20147" -m "Co-Authored-By: Claude Opus 5.5 Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44" ```