# SFM: Series-4 parity and a device safety layer — design **Date:** 2026-10-20 · **Branch:** `feat/series4-sfm-parity` · **Status:** draft for review **Decided with:** Brian, in conversation 2026-10-19/20. ## In plain terms SFM can already *read* a Micromate almost as well as it reads a MiniMate, but only through the Python library and bench scripts. SFM's web endpoints still only speak Series 3. This design does three things: 1. Gives Series 4 the same everyday jobs in SFM that Series 3 has: identify a unit, check its status, read its settings, list and download events, start/stop monitoring, and change its settings. 2. Adds a **safety layer** every device request goes through. It makes sure a command only reaches the unit it was meant for, logs every change, and checks every change by reading the unit back. 3. Lets SFM **stay on the line** with a Micromate. It calls up once, confirms the serial, and keeps the connection open for later commands instead of reconnecting each time. **The guiding principle (Brian): talking to a Series 3 unit and talking to a Series 4 unit is the same for the user.** It is the same screens, the same endpoints, the same way of naming a unit, and the same shape of answer. The only visible difference is the serial (`UM…` vs `BE…`) and the settings each model has. The differences live underneath, in one adapter per series. It does **not** cover the emergency tools (runaway-unit stops, rescue, erase), the call-home receiver, or anything async. Those come later, as features shared by both series. **Production reach, stated honestly:** while THOR is set to stay connected to production Micromates, a modem's single connection is taken. SFM can't reach those units until THOR lets go or SFM takes over call-home. In this phase, Series-4 SFM is for the bench and for units THOR is not holding. --- ## Decisions | decision | why | who | |---|---|---| | **One user experience for both series** | the user's method is identical; only the serial prefix and each model's settings differ; adapters absorb the rest | Brian | | Match **jobs**, not endpoints | some Series-3 endpoints only exist to work around Series-3 quirks | agreed | | **No Series-4 emergency tools** yet (runaway stop, rescue, erase) | Micromates rarely need them | Brian | | The series comes from the **serial prefix**: `UM` = Micromate, `BE` = MiniMate Plus, `BA` = Blastmate | the prefixes are definitive, so there is no probing | Brian | | Before any **write**, confirm the unit that answered is the one named | SFM addresses units by IP; a moved modem or stale IP means a different unit answers | agreed | | **Synchronous** endpoints for now; async later, for both series together | parity first, then shared features | agreed | | **No library of setup files on the PC** (unlike THOR). The unit's own settings are the truth: SFM reads them from the unit, and verifies every push by reading the unit back | THOR keeps one copy of each setup on the PC and another on the unit, linked only by file name. Nothing checks the contents match, so the PC's `test2` and the unit's `test2` can say different things | Brian | | **Sessions for Series 4 now; Series 3 only after a bench test** | THOR holds Micromate lines daily without harm; a MiniMate's hangup/DCD behaviour is untested | Brian | | Audit log in **SFM's database** (new table) | Terra-View can show it; it fits the existing `CREATE TABLE IF NOT EXISTS` pattern | proposed | --- ## Scope: the parity table Rows 8 and 11 of the original inventory (runaway stops, rescue/erase) are out of scope by decision. Row 6 (monitor log) moved to the parking lot: it is its own piece of work, together with call-in monitor-log ingest. | # | job | Series 3 in SFM today | Series 4: protocol status | Series 4 in this phase | |---|---|---|---|---| | 1 | Identify a unit | `/device/info` (walks the whole chain, slow) | implemented: `connect()` | dispatch to the Micromate client | | 2 | Quick status (monitoring, battery, memory, clock) | `monitor/status`, `storage_range`, `events/index` | implemented: `get_state()`; the `0x06` event count is decoded only in the bench tool | same endpoints; move the count decode into the client | | 3 | Read settings | compliance in `/device/info`; `GET /device/call_home` | `get_setup()` implemented and verified on hardware; call-home: enable + dial string observed, rest unmapped | setup in full; call-home returns enable + dial string + raw | | 4 | List events | `/device/events` (downloads every event to list them) | implemented, and cheap: the chain walk returns sizes | the same event-list shape as Series 3, each event carrying an `event_id` | | 5 | Download an event | `/event/{i}`, `/waveform`, `/blastware_file` | implemented: streams the `.IDFW`/`.IDFH` itself, with a decode self-check | the same download and save-to-DB actions as Series 3. Underneath, Series 4 saves through `/db/import/idf_file` | | 7 | Start / stop monitoring | `monitor/start`, `monitor/stop` | mapped, identical to Series 3 (`0x96`/`0x97`, acks `0x69`/`0x68`); never sent | **first write.** Verify with `0x49` state | | 9 | Change call-home settings | `POST /device/call_home` | write mapped (`0x2C` → `0x7E`/`0x7F`, same as Series 3); field map mostly unknown | enable/disable only; the rest waits for the THOR round | | 10 | Change recording settings | `POST /device/config` | sequence mapped (`0xDA` → `0x68/73` → `0x82/83` → `0x71/72`); no encoder | read-modify-write, stop → push → restart, verify with `get_setup()` | --- ## Architecture ### One door for every device request A new module, `sfm/device_access.py`, sits between the `/device/*` handlers and the two device libraries. No handler opens a transport or picks a library itself any more. ``` /device/* handler │ (serial, address, action, tier) ▼ device_access ── series from serial prefix ── session / per-unit lock │ │ │ │ ▼ ▼ │ minimateplus (S3) or micromate (S4) audit table ▼ read-back verification (changes only) ``` - **Naming a unit is the same for both: `serial` + address.** The prefix picks the adapter: `UM` → Series 4 (`micromate`); `BE` or `BA` → Series 3 (`minimateplus`); any other prefix → 422. A request with no `serial` is treated as Series 3. That is a **legacy path** kept only so existing scripts keep working; the webapp and every new caller always send `serial`. - **One contract.** Same `/device/*` paths, same request parameters, and **the same response models for both series**: - `UnitInfo`, `UnitStatus`, `UnitSettings`, `EventRef`, `ChangeResult` - Anything only one series has goes under a `detail` object inside the same model, never as a different top-level shape. `"series": 3 | 4` is informational. - **Events have one identity.** An opaque `event_id` string from the event list, passed back to download it. Underneath it is Series 3's position or Series 4's device key, plus the serial; the user never handles either. - **Not-yet-supported is uniform.** If one series can't do something yet, the endpoint still exists and answers **501 "not supported for Series N yet"**. It is never a missing route or a different call. - **Work separate from HTTP.** Each operation is a plain function taking the session. The handler is a thin wrapper, so making an operation an async job later means changing the wrapper, not the operation. ### Adapters Each series implements the same operation set behind `device_access`: | operation | Series 3 adapter | Series 4 adapter | |---|---|---| | `identify` | STARTUP + serial + config | `connect()` | | `status` | `0x1C` (+ `0x06`) | `get_state()` + `0x06` count | | `read_settings` | `0x1A` compliance decode | `get_setup()` | | `list_events` | today's walk | chain walk (cheap) | | `download_event` | 5A → Blastware file | 5A → `.IDFW`/`.IDFH` | | `start` / `stop` | `0x96` / `0x97` (exists) | `0x96` / `0x97` (new) | | `read_call_home` / `set_call_home_enabled` | exists | `0x2C` / `0x7E`+`0x7F` | | `push_settings` | `/device/config` path (exists) | setup push (new) | | `call_up` / `hang_up` | connect-per-request underneath, until the bench test | held session | Each adapter maps its native data into the shared models. `UnitSettings` keeps the fields both series have under the same names and units: record mode, sample rate, record time, histogram interval, trigger levels, the notes as label → value. Model-specific fields go under `detail`. **Requests that include `serial` get the shared models; requests without it keep today's Series-3 shapes, unchanged.** Nothing breaks in between: the webapp moves to `serial` in phase 1c, and the old path retires after that and after `watch_unit.sh` moves. Terra-View does not call `/device/*`. The emergency endpoints (`stop_monitoring_*`, `rescue`, `events/erase`) are not touched and stay Series-3 only; a `UM` serial gets 501. ### The webapp The same screens for both series. You name a unit by serial + address (today it takes host/port only), and the series shows as a badge, nothing more. Read panels for both series land in phase 1; each write button appears for Series 4 in the phase that adds that write. ### The safety layer **Tiers.** Every operation declares one: | tier | examples | what the layer does | |---|---|---| | read | info, status, setup, events, download | runs; no identity check | | change | start/stop, call-home, setup push | identity check → audit → send → **read back** → audit the result | | destructive | delete, erase (none in this phase) | everything above + the caller must send the unit's serial as `confirm` | **Identity check (changes only).** Before the first change in a connection, compare the serial the unit reports with the one requested; on a mismatch, refuse (409) and send nothing. Series 4 already reads the serial in `connect()`. A Series-3 change adds one serial read (`SUB 0x15`), about one round trip. **Opcode guard.** A send-side check that refuses known cross-series collisions. It starts with **`0xA2`**, which is CONFIRM ERASE on Series 3 and "end call-home" on Series 4. This phase never sends `0xA2`; the guard makes that impossible by accident. The table of colliding opcodes lives in one place. **One connection per unit.** A per-unit lock keyed by address (`tcp:host:port` / `serial:port`). A request for a busy unit waits up to **20 s** (configurable; under Terra-View's 60 s proxy timeout), then gets **423 "unit busy"** instead of opening a second connection. This applies to Series 3 as well. The webapp's Diagnostics refresh currently fires three device requests at once against a modem that allows one; under the lock they queue. **Read-back verification.** A zero-data ack has never been proof that a write applied. Every change is followed by a read: - start/stop → `0x49` state: start expects `0x02`, stop expects `0x00`. Record the value either way; `0x03` is the in-call-home state - call-home → re-read `0x2C` and compare the edited bytes - setup push → `get_setup()` and compare every field that was set A mismatch is reported as a failed change (and audited as one), even if the ack was clean. **Errors that say what happened.** Distinct responses for: - 503: couldn't connect - 504: connected but the unit didn't answer - 423: unit busy - 409: wrong unit - 422: bad input - 502: the reply was malformed Today 502 covers both of the first two. **Audit table.** New table `device_commands`, created on startup like the others. It is additive, but still a schema change, so the changelog says so. One row per change attempt: | column | content | |---|---| | `ts`, `serial`, `series`, `address` | who and where | | `action`, `tier` | e.g. `monitor_stop`, `change` | | `request` | parameters, plus hex of what was sent | | `ack` | reply summary | | `verified` | read-back result: `ok` / `mismatch` / `not_checked` | | `outcome`, `error` | final result | | `caller` | best-effort origin (`webapp`, `terra-view`, `script`) | Reads are not audited. ### Sessions 1. **Call up.** Connect, `connect()` (POLL / SERIAL / STATE), identity check against the requested serial. 2. **On the line.** Requests for that unit run in turn on the same connection, behind the per-unit lock. 3. **Keep-alive.** A POLL every 60 s while idle. The ACEmanager TCP idle timeout is 2 min. 4. **Hang up.** On `POST /device/hangup`, after 5 idle minutes, or on any transport error. A reconnect is a new session with a new identity check. 5. **Ring safety.** If `RADIO RING` arrives on an SFM session, log it and hang up **immediately**. Until SFM is the call-home destination, the unit's retry should reach THOR. 🔶 *Inferred:* the unit retries; its `0x2C` retries field reads 3. **Call up and hang up are the same for both series.** Underneath, the Series-3 adapter keeps today's connect-per-request behaviour until the bench test under *Testing*; the user sees the same actions either way. ### Series-4 write path **Encoder.** Extend `micromate/framing.py`: - a request builder that carries a data section - the same escape set `{02,03,04,10}`, applied to data, params and checksum - plain SUM8 of the destuffed payload (*not* Series 3's write format) Rules: `micromate_protocol_reference.md` → *The escape set — exactly four bytes*, *Checksum — plain SUM8 of the de-stuffed payload*, *Write-frame destuffing*. **Dry run.** Every Series-4 write accepts `dry_run=true`. It returns the exact frames it would send and sends nothing. The first live send of each write is reviewed this way first. **Per operation:** | operation | frames | verify | open questions it settles | |---|---|---|---| | start / stop | `0x96` / `0x97`, offset `0xFFFF`, zero params | `0x49` | the ack when already in that state | | call-home enable/disable | read `0x2C` → `0x7E` (126 B content, offset `0x007E`) → `0x7F` | re-read `0x2C` | none new; bit 0 of `write[5]` | | setup push | read `0x08`, `0x2E`, `0x1A` → `0xDA` (name) → `0x68`/`0x73` → `0x82`/`0x83` → `0x71`/`0x72` | `get_setup()` | the offset rule; whether `0x68`/`0x82` are needed | **Setup push, details:** - Read-modify-write of **all three** blocks, as THOR appears to do. 🔶 *Inferred from two captures:* `0x68` = the preferences content with `[0:3]` zeroed; `0x82` = the `0x2E` content with `[0:3]` and the CRC slot zeroed; `0x71` = the `0x1A` content `[0:2090]` with the length echo zeroed. - Offsets come from THOR's observed constants. 🔶 The hypothesis "offset = the read block's length + 2" fits all four, but each has been seen at one size only. - The edited fields come from `MicromateSetup` and are written back at the offsets `setup_block.py` already uses. Only fields graded **measured** may be edited. - Sequence: stop monitoring (if running) → push → restart (if it was running) → verify. THOR's "must be idle" is policy, not the device, but stopping first removes a variable from the first live write. - ⚠ **Edit-buffer hazard.** `0x1A` reads the keypad's unsaved edits, so a read-modify-write taken while someone is in the menu would commit them. This can't be detected from the wire; it is documented in the endpoint and audited. - **Target file:** the active setup, overwritten in place, by default. A named target is allowed, but overwriting a *non-active* setup or `factory.MMB` is untested, so it is refused in this phase. --- ## Testing **Offline (CI-capable):** - **Frame reproduction.** The new encoder must reproduce THOR's captured write frames byte for byte: `0x96`/`0x97`, `0x7E`/`0x7F`, and the full setup push, from the 9-24 / 9-25 / 10-14 captures. This is the same method that proved the reads (218/218). The needed frames are copied into force-added fixtures, since `bridges/captures/` is gitignored. - **Safety layer on fakes:** - series by prefix - identity mismatch → 409, nothing sent - `0xA2` refused - lock → 423 - read-back mismatch → failed change - audit row written for every change attempt - RADIO RING → session ends - **Endpoints** through FastAPI's `TestClient` against the scripted transport already used in `tests/test_micromate_client.py`. - **Contract tests.** The same test, run against both adapters with fakes, asserts that each job returns the same model with the same field names and units. A field present for one series and absent for the other is a test failure unless it lives under `detail`. This is the test that keeps the guiding principle true as the code grows. **Bench (UM20147, with Brian):** each write's first live send follows the same protocol: 1. Dry run. 2. Review the frames. 3. Send once, with a capture running. 4. Read back. 5. Write the result into the reference. Order: stop/start → call-home off/on → setup push of one field → setup push of several fields. **Series-3 session test (before Series-3 sessions are built):** hold a call-up session open to a MiniMate that is monitoring, for several minutes. Record: - does it keep monitoring (does an event still record)? - after hangup, is it monitoring? - does it behave differently on an RV55 with the DCD issue? --- ## Build phases Each safety piece arrives with its first real use, so nothing sits untested. 1. **One contract, reads only.** `device_access.py`, the two adapters, the shared models, series selection, the per-unit lock, the error mapping, and sessions with ring safety. Rows 1–5 for **both** series through the same endpoints. **No writes.** Split into three plans: - 1a. The foundation plus identify / status / settings for both series. - 1b. Event list and download for both series (rows 4–5). Decided with Brian 2026-10-21: - **MiniMate events are listed from their headers** (`0A` + `1E` arm + `0C` + `1F` browse, no `5A`) instead of downloading every event to list it, and one event downloads without the ones before it. It reuses the bypass `skip_waveform_for_events` already takes, so no new command reaches the wire. The legacy serial-less `/device/events` keeps its full-download walk. 🔶 Unproven on a unit: **a MiniMate bench check is owed before this branch merges.** Its scope (final review, 2026-10-21): - a list of three or more events, confirming `1F(browse)` advances after a `1E(arm)` without `1F(arm)`; - a non-first event; - a histogram-mode event, capturing its `0C` (which would let Series 3's `record_type`, `null` today, be decoded); - an event past 64 KB, expecting the named 502; - a stale-id download, confirming no `5A` goes out; - a download of an event Blastware's call-home already delivered (one waveform, one histogram), expecting `already_stored`. This is the only way to measure that Series 3's (serial, timestamp) agrees between the unit's `0C` and the watcher's import; if it does not, a download silently stores a duplicate row (never a downgrade). Measured for Series 4: 1,016/1,016 watcher imports found by the lookup (2026-10-21). - a dropped reply, via `bridges/mm_link.py`-style fault injection. - **Download = fetch, check, store** in SFM's database, the same as Series 3's `blastware_file` route, and returns the stored row's id. The file and waveform are then served by the existing `/db/events/{id}/…` routes. The database matches on (serial, timestamp), so storing an event already stored, including one THOR's watcher forwarded, ~~refreshes the row instead of duplicating it~~. **Changed by the final review (2026-10-21):** it returns the existing row and writes nothing (`inserted: false`, `detail.already_stored: true`). Never merge: the watcher's copy, with its paired report, is the richer one, and a refresh measurably downgraded it (PVS, project strings and ZC frequencies went NULL). - **`event_id` = `::`.** Both series reuse keys (after an erase, and across Micromates), so a download whose key now holds a different event fails with 409 instead of fetching it. - **Micromate downloads walk to the event first** (the only order captured from THOR), with THOR's 1,024-byte chunks. - 1c. **The webapp:** serial + address, and the same read panels for both series. - ~~**HARD PREREQUISITE:** before any poller or webapp sends `serial`, add a per-address cool-down after a RADIO RING~~ -- **changed 2026-10-23 (Brian): test first, build only if needed.** Before any poller or webapp sends `serial`, run the ring-path bench test under *Open questions this design leaves for the bench*. If Run B shows a poller keeps the call from reaching THOR, add the per-address cool-down: call-ups to that address answer 503 + `Retry-After` until it expires, and `POST /device/hangup` clears it, with its length taken from Run A. If THOR gets the call anyway, no cool-down is needed. 2. **Encoder + opcode guard + dry run + frame-reproduction tests.** Still nothing sent. (2026-10-22) "Dry run" in this phase means the **write plan**: the exact frames, in order, with their expected acks, built from the unit's own reads (`micromate.writes`), plus a bench tool that prints one from a live unit's reads (`bridges/mm_dry_run.py`). Each write endpoint's `dry_run=true` arrives with that write in phases 3-5 and returns the plan. The opcode guard is a **send-side gate** in `MicromateProtocol._send`: every write SUB is refused unless the connection was built with it allowed (none is, in this phase), and `0xA2` is refused always. 3. **Start/stop monitoring** (row 7): the first live write, at the bench. Brings the identity check, the audit table and the read-back framework. - **Preconditions from the phase-2 final review (2026-10-22):** - **Write permission is scoped to one call, not a connection.** `MicromateProtocol.execute(plan)` is the only write path: it transmits exactly that plan's frames and nothing else. The connection's own `allowed_writes` stays empty -- a held `Series4Session` lives for minutes, and a grant made at call-up would outlive the request. - **A code-reviewed ceiling** in `micromate/opcodes.py` lists the write SUBs any code may transmit: `{0x96, 0x97}` in this phase, each later phase adding its own. Delete (`0xA8`/`0xAA`), raw file writes (`0x8D`/`0x8E` -- they could reach the modem settings) and `0xA2` are enabled only by a spec change. - **A write is never retried.** `DeviceAccess._dispatch`'s retry-once refuses change-tier operations structurally, not by comment. - **Build the plan inside the unit lock, on the same line, right before sending.** A plan returned by an earlier dry run is never transmitted; optionally the dry run returns a digest the live call must echo. - **Read state first** (`0x49` for start/stop, `0x2C` for call-home) and decide on purpose whether "already in that state" is skipped or is the experiment. - **Refuse writes unless this connection's responses carried Micromate flags** (0xC5/0x03), alongside the serial identity check. 4. **Call-home enable/disable** (row 9). 5. **Setup push** (row 10): one field first, then several. Each phase is its own implementation plan. **All phases land on `feat/series4-sfm-parity` and merge to `dev` once, when everything here is implemented** (Brian, 2026-10-21) — not one merge per phase. --- ## Out of scope (this phase) - Series-4 emergency tools: runaway stops, rescue, per-event delete, erase. (Erase-all is also unmapped.) - Async jobs; auth (Terra-View as jump host); the call-home receiver. These are shared features for later. - Scheduler read/write/enable; clock set; remote sensor check; restart; firmware. - Series-3 sessions, pending the bench test. - Mapping the rest of `0x2C` (the THOR round). ## Fix list (found 2026-10-19, separate small changes) - `bridges/ach_server.py:524`: `seen_keys` is undefined. Series-3 call-home monitor-log collection has failed every session since `9afa348` (2026-05-07). - `bridges/mm_ach_server.py:262`: `_cstring`/`_content` aren't imported, so the ring-answer path would raise `NameError`. From `8f67608` (2026-10-14). - Series-3 `5A` 64 KB page-boundary bug (known; surfaces as HTTP 500). - `POST /device/config` writes a fixed 29-byte `0x82` blob from one 3-11-26 capture, whatever the unit's trigger settings. - `/device/events` runs a full 5A download per event just to list headers. - `0x08` is named `read_event_index` in `micromate/`; it is the preferences block. ## Left open by the phase 1a review (2026-10-21) Minor findings from the whole-branch review, parked here so they outlive the plan's scratch ledger. None blocks 1a; the phase each one matters to is named. - **CORS ordering (1c, if a browser calls SFM directly).** The `/device` guard middleware is registered after CORS, so it sits outside it: its 409/501 responses carry no `access-control-allow-origin`, and an OPTIONS preflight to a guarded URL gets the guard's refusal instead of CORS's 200. Register CORS last, or let OPTIONS through. Terra-View proxies server-side and is not affected. - **Legacy handlers take no unit lock (1c / phase 3).** The guard checks for a held line and then lets the legacy handler run unlocked; a legacy request admitted just before a Series-4 call-up at the same address can overlap it. - **Address keys are not normalised.** `tcp::` is the raw string: a hostname vs an IP, or `/dev/serial/by-id/...` vs `/dev/ttyACM0`, gets two locks for one link. - **A serial-less request to an UNHELD Micromate still runs Series-3 bytes.** The guard only knows about lines SFM holds. ~~This is the phase-2 opcode guard's job.~~ **Measured by the phase-2 final review (2026-10-22):** the phase-2 gate covers `micromate/` only and cannot see this traffic. Only the three blind stop tools (`/device/stop_monitoring_blind`, `_slow_drip`, `_spam`) send a write before any parsed reply. Every other legacy write route needs a parsed `0xA4` POLL reply, and `S3FrameParser` never yields one from Micromate bytes (364 real responses → 29 spurious frames, none `0xA4`). So erase, config and call-home writes cannot reach a Micromate. Worst case (inferred): an unheld Micromate at the address stops monitoring, via the Series-3 `0x97` at offset 0x0000, never sent to one. The hazard is identity (a moved modem or a stale IP), not series. **Brian's decision** (the legacy routes are bound by 'behave exactly as today'): accept until the legacy path retires after 1c, then require `serial` on the blind tools; or, as an interim, refuse a blind tool when SFM's DB last saw a `UM` serial at that host. - **`tcp_port` coercion mismatch.** The guard parses with `int()`, pydantic coerces more loosely (`"9034.0"`), so such a request passes the guard unchecked. Parse with pydantic's own int coercion, or fail closed. - **Test gaps.** The middleware wrapper itself is untested (a raw ASGI call works without httpx); the contract test compares field names of one shared dataclass, which cannot fail, and does not enforce "a field absent for one series lives under `detail`". - **`_ensure_reaper` race.** Two first Series-4 requests at once can start two reaper threads; harmless because `try_hold` keeps them off each other's units. - **Held serial lines share `/dev/ttyACM0` silently.** pyserial's open is not exclusive, so a bench script beside a held line interleaves bytes with the keep-alive; it looks like a dead unit. Open with `exclusive=True`, or don't hold serial links. ## Left open by the phase 1b review (2026-10-21) Parked from the whole-branch review of 1b; none blocks it. The phase each matters to is named. - **Retry re-runs a whole download (1c).** The retry-once on a held-line timeout re-runs the full download, roughly doubling time-to-error; narrow it to failures before the first reply. - **`last_used` after a kept-line error (1c).** It is not refreshed when an op's verdict (404/409) keeps the line, so the idle hang-up comes early. - **`verified: null` is ambiguous (1c).** It means both "a histogram" (no check exists) and "a waveform whose check could not run". - **Mic naming and the Series-4 mic decode (1c).** `detail.mic_psi` on Series 3, `detail.mic` on Series 4; Series 4's `0x0C` mic decodes as a denormal (~5e-39) — fix the decode before 1c shows it. - **500 detail leaks paths (1c, before SFM is reachable beyond Terra-View).** The download handler's 500 detail includes raw exception text, filesystem paths included. - **Serial as a directory name (1c).** The serial is never checked against `[A-Z0-9]+` before it names a store directory; only the unit can choose it, but the check is cheap. - **No server-level RADIO RING mid-download test (1c).** Covered structurally (DeviceAccess-level test + the ring transport), not through the handler. - **Series-3 stored `record_type` (MiniMate bench check).** Rows SFM stores for Series 3 still say "Waveform" for histograms — pre-existing, the same as the legacy `blastware_file` route; fix it with the `0C` decode. - **A fresh Series-4 download's gaps (1c).** No `sample_rate` is stored, and the sidecar has no vector sum; the DB row has the unit's PVS (overlaid from `0x0C`). - **Orphan files (SDM).** An event file in the store with no DB row is still overwritten by a download. - **Same-second collisions (SDM).** Two events of one unit in the same second collide on (serial, timestamp) — a DB-wide dedup property, not 1b's. - **423 without `Retry-After` (1c).** Add `Retry-After` to the 423 a request gets while a download holds the unit. - **A lost `0C` during a Series-3 list (1c).** The strict walk raises on a lost `0A` or `1F`, but a lost `0C` still lists the event with no timestamp and an `event_id` ending `:-`. Downloading that id skips the stale check and runs the full `5A`. If the `0C` is lost again it is refused (no timestamp, no filename); if it reads, whatever event now sits at that key is stored with no stale check: self-consistent data, but possibly not the event that was listed. Fix: raise on a lost `0C` in strict mode, or refuse `:-` ids for Series 3. - **A lost reply on a Series-3 TCP walk re-runs it once (1c)** under the adapter's cold-boot retry before the 504, doubling time-to-error on a bad link. - **A Series-3 download of an already-stored event still runs the full `5A`** before the database lookup finds it (the lookup is on the SDM side, after the device layer). Wasted transfer, not bad data (1c). ## Left open by the phase 2 review (2026-10-22) - **`plan_setup_push` takes any name (phase 5).** It is not tied to the `0x41` read, and it does not refuse `factory.MMB` or a non-active target, which the spec requires; the name's case varies (`test2.MMB` vs `test2.mmb`). - **Stripped-name caveat.** `get_active_setup()` strips whitespace, so a name with leading or trailing spaces does not round-trip. - **Bench questions.** Whether a Micromate honours offset 0x0000 on `0x96`/`0x97`, accepts a no-op call-home write, or accepts 0x00 at `[5]`. Settle all three at the bench. - **Phase-5 lead (inferred).** Comparing `0x1A` against the active `.MMB` read through `0x94`/`0x48` may detect unsaved keypad edits, which would undercut "can't be detected from the wire". One bench check. ## Table 2: to be added later (both series) | area | item | |---|---| | infrastructure | async jobs; auth via Terra-View | | THOR has it, SFM doesn't | clock set; remote sensor check; scheduler; one setup to many units; restart | | call-home receiver | hold lines open (S4); "already downloaded" tracking; rules by serial prefix (copy events, monitor log, delete, set clock); detect "Monitor While Calling Home" blocking deletes (⚠ one unexplained 21 → 5 count drop in THOR's log); hand off to `/db/import/*` instead of the watchers | | settings, the no-PC-files way | intended settings per deployment; drift report (intended vs actual); push then verify | | notifications | email/SMS by event type and PPV (THOR does it; may belong in Terra-View) | | emergency tools for S4 | if a Micromate ever needs them | ## Parking lot **Monitor logs.** Its own piece of work, data side as much as device side. A unit calls in at least once or twice a day. With no events (e.g. waveform mode, no blast that day) it still delivers a **monitor log**: "monitoring from X to Y". The watchers (one for BW-ACH / Series 3, one for THOR-ACH / Series 4) use the newest file per unit, event or `.MLG`, as SFM's "last heard from" age. They forward waveform and histogram files but **not** monitor logs. To decide: - Ingest call-in monitor logs into SFM. SFM's DB **already has** a `monitor_log` table (one row per interval, deduped by serial + start time), and `minimateplus/blastware_file.py` already parses Series-3 `.MLG`. Missing: anything that takes `.MLG` in from the watchers, and knowledge of THOR's Series-4 monitor-log file format. - A live monitor-log read over a connection (Series 4: `0x0A` exists, no wrapper or decoder; Series 3 in SFM: none). - What it is for: proof of coverage ("was it monitoring when they blasted?") and visible gaps. - Related fix-list item: `ach_server.py`'s `seen_keys`. **How SFM handles setup files and schedules.** This phase only reads and pushes the unit's *active* setup, with no PC-side library (the `.mmb` same-name/different-contents gotcha). Still to decide, as one question because the two are coupled: - The unit stores up to 25 named `.MMB` files. Should SFM manage them (list, select, rename, delete, push to a named file), or only ever touch the active one? - **Schedules name setup files.** A schedule entry switches the unit to a setup by name, so a schedule is only as reliable as the files it points to. What if it points to a file that isn't there? That is untested. - How "intended settings per deployment" (Table 2) fits with files and schedules. - Scheduler read/write is mostly mapped (file transfer + `0x47`); **disable has never been captured**. **A modem-side agent on the RX55.** AirLink OS on the RX55 has "Container Applications (Early Adopter)", and Brian already runs `slmm-proxy` there. A small program owning the unit's serial port could: - let THOR and SFM share the line - dial out to SFM, avoiding the IP whitelist - handle `RADIO RING` locally - **Brian's hunch:** make RX55s work with Series 3 by driving DTR/DCD itself Open questions: - Can a container open the RS-232 port? - Can it set the control lines? - How is it deployed to a fleet, and does it Autostart? - Will a firmware update keep the beta feature? ## Open questions this design leaves for the bench - **Ring path and retries: does a Micromate's call-home reach THOR when SFM holds its line?** (Test designed 2026-10-23; decides whether 1c needs a cool-down.) - *Already measured (10-14):* with THOR holding the line, the ring arrived on THOR's own outbound connection (`TcpClientSystemNet ... RADIO RING IS RECEIVED FROM IP:...:9034`), so the modem did not divert it to the destination. Unmeasured: the same with SFM as the holder, and what the unit does after the holder releases. - *Known from the firmware strings:* "three attempts and it's over". 🔶 Inferred: 60 s between attempts (`0x2C` content `[120:122]` = `00 3c`, Series III's "time between retries" offset), and about 21 s of ringing per attempt (10-14 capture). - *Setup:* a bench Micromate on a modem whose destination is the office THOR-ACH server, and a unit THOR is not otherwise watching. SFM runs on a test port with a scratch DB. Keep THOR's ACH log open. - **Run A, one call-up:** SFM calls the unit up and holds the line (any serial-named read). Trigger a call-home on the unit. Record: - whether SFM logs the RADIO RING and hangs up, with the time; - whether and when THOR starts a session (its ACH log); - the number and spacing of rings and attempts. - **Run B, a poller:** as A, but a script requests the unit's status every ~10 s throughout. If THOR still gets the call, no cool-down is needed; if the poller keeps the call from reaching THOR, build it, sized from Run A. - *Also settles:* whether the modem routes a call-home to its destination on its own, in which case SFM never sees a ring and THOR gets the call while SFM is still connected. - The ack for start/stop when the unit is already in that state. - The offset rule, and whether `0x68`/`0x82` are required, for the setup push. - Whether the device ever refuses a write while monitoring. Only THOR's policy has been seen. - How a failed write is signalled. It has never been observed. - MiniMate behaviour with a held session (above).