serversdownandClaude Opus 5.5 ba826dfac6 fix(mlg): final-review fixes
A fresh whole-branch review found four Important issues; three of its
Minors and one item it set aside were re-graded up.  Each has a test that
failed first.

- A windowed timeline 500'd when a file came without its modified time
  (Python 3.10 rejects the 'Z' of received_at).  received_at is now
  +00:00 and timeline times parse 'Z' too.
- On the clock-step day an event-triggered call-in moved the event into
  the next session and lost the step.  An event now joins the 'monitoring
  started' record of its own file.
- A call-in whose records came first in another file (a cable download)
  read 'nothing_new'.  Each file now keeps its own call summary
  (last_stop, no_file_stops) from when it arrived.
- Sessions and call-ins now carry record_ids / file_ids / file_id, the
  shot report's proof (spec 5).
- A non-'started' record with no stop made the unit's timeline 500 for
  good; it now opens a session whose end is unknown.
- A serial from a file's bytes (or a hint) could write outside the store;
  only plain serials are used, and records with no serial are refused, not
  dropped.
- Times with a UTC offset, an empty 'at', or a bad mtimes value gave 500s
  (or stored half a request); they are now 400s, checked first.
- A missing call-in file made the gap after its Modem Exit read 'not
  monitoring' for days.  Files are numbered <serial><counter>; a gap
  across a missing number is now 'records missing' (unknown).  A long gap
  after a call-in with no number missing is 'no restart after a call-in':
  real outages on the DL2 data (BE6907 14 days from 2026-10-07; BE8081
  over Labor Day 2019).  Real fixtures BE6907 #899-#902 added.
- Docs: BE8081 did write one empty file (BE80811.MLG).