Files
serversdownandClaude Opus 5.5 c790e20116 fix: bench follow-ups -- the setup-menu warning, observed call-home values, waveform read
From the 2026-11-04 bench:
- A MiniMate settings preview warns that a change is lost if someone is in
  the unit's setup menu: a write sent with the menu open was acknowledged
  and read back, then lost on Cancel or Save -- the menu writes its own
  copy of the whole block back (measured both ways on BE9441).
- The two bytes after the MiniMate settings block went out as 00 00 and
  the unit took them; the preview note says so instead of 'unmeasured'.
- A Micromate call-home plan no longer warns about 0x00 / 0x01: UM20147
  took both, each way, on 11-03 and 11-04, matching its menu.
- read_waveform_data_raw drops the escaped-checksum's stray 0x10, as the
  settings read does (it failed closed: the write's block check refused
  203 bytes).

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-11-04 16:15:28 -05:00

195 lines
8.7 KiB
Python

"""Write plans for a Micromate: the exact frames a write would send, in order.
A plan is what a dry run returns. Building one sends nothing; transmitting it
is `MicromateProtocol.execute(plan)` and nothing else: the connection holds no
write permission of its own (see `micromate.opcodes`).
Every input is the unit's OWN read of the block being written (content, i.e.
response data[11:]), and every plan sends back exactly what was read except
the one thing the operation changes. THOR works the same way, and the
reproduction tests hold the plans to THOR's frames byte for byte.
Offsets are THOR's observed constants. 🔶 Each was seen at one block size
only, so a plan refuses a block of any other size rather than guess.
"""
from __future__ import annotations
from dataclasses import dataclass, field
from typing import FrozenSet, List, Tuple
from .framing import build_request
from .opcodes import CROSS_SERIES_COLLISIONS, WRITE_SUBS, OpcodeRefused
from .setup_block import crc_ok
_CONFIRM = 0xFFFF
_CALL_HOME_OBSERVED = (0x00, 0x01, 0x04, 0x05) # content[5] values units have held
# block content sizes THOR's offsets were observed at (all on UM12947 / 11.0CB)
_PREFS_LEN, _TRIGGER_LEN, _SETUP_LEN, _CALL_HOME_LEN = 90, 28, 2092, 126
_NAME_FIELD = 256
@dataclass(frozen=True)
class WriteStep:
sub: int
offset: int
data: bytes = b""
params: bytes = field(default=bytes(10))
what: str = ""
def __post_init__(self) -> None:
# Freeze the bytes: a caller's bytearray must not change a validated step.
object.__setattr__(self, "data", bytes(self.data))
object.__setattr__(self, "params", bytes(self.params))
if len(self.params) != 10:
raise ValueError(f"params must be 10 bytes, got {len(self.params)}")
if not 0 <= self.offset <= 0xFFFF:
raise ValueError(f"offset 0x{self.offset:X} does not fit a uint16")
if not 0 <= self.sub <= 0xFF:
raise ValueError(f"SUB {self.sub!r} does not fit a byte")
@property
def ack_sub(self) -> int:
return 0xFF - self.sub
@property
def frame(self) -> bytes:
return build_request(self.sub, self.offset, self.params, self.data)
def describe(self) -> dict:
return {"sub": f"0x{self.sub:02X}", "what": self.what,
"offset": f"0x{self.offset:04X}", "data_len": len(self.data),
"expect_ack": f"0x{self.ack_sub:02X}", "frame": self.frame.hex()}
@dataclass(frozen=True)
class WritePlan:
action: str
steps: Tuple[WriteStep, ...]
warnings: Tuple[str, ...] = ()
def __post_init__(self) -> None:
# Copy: a caller's list must not be able to add a step after validation.
object.__setattr__(self, "steps", tuple(self.steps))
object.__setattr__(self, "warnings", tuple(self.warnings))
for s in self.steps:
if not isinstance(s, WriteStep):
raise TypeError(f"a plan holds WriteStep objects, got {type(s).__name__}")
if s.sub in CROSS_SERIES_COLLISIONS:
raise OpcodeRefused(
f"a plan cannot hold SUB 0x{s.sub:02X}: {CROSS_SERIES_COLLISIONS[s.sub]}")
if s.sub not in WRITE_SUBS:
raise ValueError(f"SUB 0x{s.sub:02X} is not a write opcode")
@property
def subs(self) -> FrozenSet[int]:
return frozenset(s.sub for s in self.steps)
def frames(self) -> List[bytes]:
return [s.frame for s in self.steps]
def describe(self) -> dict:
return {"action": self.action, "sends_nothing": True,
"warnings": list(self.warnings),
"steps": [s.describe() for s in self.steps]}
def plan_start_monitoring() -> WritePlan:
return WritePlan("start monitoring", (WriteStep(0x96, _CONFIRM, what="start monitoring"),))
def plan_stop_monitoring() -> WritePlan:
return WritePlan("stop monitoring", (WriteStep(0x97, _CONFIRM, what="stop monitoring"),))
def is_call_home_content(block: bytes) -> bool:
"""Whether 126 bytes are the 0x2C call-home content: its header is its own
length (00 7C, N = 124 -- 00 7C DC on every read on record, UM12947 and
UM20147). A bit is flipped only in a block that carries it."""
return len(block) == _CALL_HOME_LEN and int.from_bytes(block[0:2], "big") == _CALL_HOME_LEN - 2
def plan_call_home_enabled(call_home: bytes, enabled: bool) -> WritePlan:
"""Read `0x2C`, flip bit 0 of content[5], send the rest back byte for byte.
Bit 0 of `[5]` is the enable. 🔶 UM12947 (THOR's unit) read 0x05 enabled /
0x04 disabled, bit 2 set in both; UM20147 reads 0x01 (measured, phase-2 dry
run). So on UM20147 "off" writes 0x00 -- measured at the bench 2026-11-03
(and again 11-04): 0x01 <-> 0x00 acknowledged, read back, and matched in the
unit's own menu. A value outside those four still carries a warning.
`[118:120]` is unit-maintained and THOR echoes it.
"""
if len(call_home) != _CALL_HOME_LEN:
raise ValueError(f"call-home content must be {_CALL_HOME_LEN} B "
f"(the size THOR's offset was seen at), got {len(call_home)}")
if not is_call_home_content(call_home):
raise ValueError(f"call-home content's header is {call_home[0:2].hex()}, not its own length "
f"(00 {_CALL_HOME_LEN - 2:02x}) -- not the call-home block; nothing built")
b5 = (call_home[5] | 0x01) if enabled else (call_home[5] & 0xFE)
data = call_home[:5] + bytes([b5]) + call_home[6:]
what = "call-home " + ("enable" if enabled else "disable")
start = call_home[5]
warnings = []
if start not in _CALL_HOME_OBSERVED or b5 not in _CALL_HOME_OBSERVED:
warnings.append(f"content[5] 0x{start:02X} -> 0x{b5:02X}: no unit has been seen "
"holding this value (0x04/0x05 UM12947 by THOR, 0x00/0x01 UM20147 "
"by SFM); it is unobserved")
if b5 == start:
warnings.append(f"the unit is already call-home {'enabled' if enabled else 'disabled'}"
" -- this write changes nothing")
return WritePlan(what, (
WriteStep(0x7E, 0x007E, data, what="call-home config write"),
WriteStep(0x7F, _CONFIRM, what="call-home config confirm"),
), tuple(warnings))
def _checked(block: bytes, size: int, label: str) -> bytes:
if len(block) != size:
raise ValueError(f"{label} block size {len(block)} B is not the {size} B "
"THOR's offset was observed at -- refusing to guess")
if int.from_bytes(block[0:2], "big") != size - 2:
raise ValueError(f"{label} block's own header says "
f"{int.from_bytes(block[0:2], 'big')}, expected {size - 2} -- "
"not the block it claims to be")
if not crc_ok(block):
raise ValueError(f"{label} block failed its checksum -- refusing to write a "
"corrupt read back to the unit")
return block
def plan_setup_push(prefs: bytes, trigger: bytes, setup: bytes, name: str) -> WritePlan:
"""Rewrite a setup as THOR does: read 0x08, 0x2E, 0x1A, send each back.
No field editing here (phase 5). Each block goes back with its length echo
[0:3] zeroed; the unit recomputes the CRCs, so 0x68 and 0x71 drop the CRC
slot and 0x82 sends it zeroed -- exactly THOR's frames.
⚠ `0x1A` reads the keypad's edit buffer live. A setup read taken while
someone is in the unit's menu includes their unsaved edits, and pushing
this plan would commit them.
The name goes out exactly as given. `MicromateClient.get_active_setup()`
strips whitespace, so a setup name with leading or trailing spaces would
not round-trip through it; phase 5 decides whether to take the unstripped
name from the 0x41 read.
"""
_checked(prefs, _PREFS_LEN, "preferences (0x08)")
_checked(trigger, _TRIGGER_LEN, "trigger (0x2E)")
_checked(setup, _SETUP_LEN, "setup (0x1A)")
try:
raw = name.encode("ascii")
except UnicodeEncodeError:
raise ValueError(f"setup name must be ASCII: {name!r}") from None
if not raw or b"\x00" in raw or len(raw) >= _NAME_FIELD:
raise ValueError(f"setup name must be 1-{_NAME_FIELD - 1} ASCII bytes "
f"with no NUL: {name!r}")
return WritePlan(f"setup push: {name}", (
WriteStep(0xDA, 0x0100, raw.ljust(_NAME_FIELD, b"\x00"), what="setup file name"),
WriteStep(0x68, 0x005A, bytes(3) + prefs[3:88], what="preferences block"),
WriteStep(0x73, _CONFIRM, what="preferences confirm"),
WriteStep(0x82, 0x001C, bytes(3) + trigger[3:26] + bytes(2), what="trigger block"),
WriteStep(0x83, _CONFIRM, what="trigger confirm"),
WriteStep(0x71, 0x082C, bytes(3) + setup[3:2090], what="setup block"),
WriteStep(0x72, _CONFIRM, what="setup confirm"),
))