THOR's ACH log exposed two differences between what it does on seeing a ring and
what we were doing, and either could explain why the unit never answered us:
| ours | THOR
command | POLL (0x5B) | ReadSerialNumber (0x15)
delay | 8 s (grace window)| 36 ms
We sat silent for the whole grace window and then asked a different question.
The unit may well have given up long before we spoke.
So the grace window now ENDS THE MOMENT a RING is seen, and the ring is answered
with SERIAL first -- which is THOR identifying which unit rang before doing
anything else. The push-vs-pull experiment the window was built for is
unaffected: silence still runs the full duration.
This does not change the bigger finding that mm_ach_server is built on the wrong
model for a PAD-connected unit -- THOR's working path is a POLLER holding an
outbound connection, not a listener. But if a unit whose modem dials out can be
made to answer on the inbound path too, that is worth knowing before the rewrite,
and it costs two small changes to find out.