Files
seismo-relay/docs
serversdownandClaude Opus 5.5 0a87d85202 fix(sfm): a MiniMate download's peaks come from its file when the unit confirms Normal range
Since the decode checker's histogram-PVS fix (625bc39, merged 6945009) the file
reads a histogram's vector sum as the unit stored it: K441LTON.900 stores
0.200 / 0.385 / 0.255 and a vector sum of 0.3852, as Blastware's report (was
0.503).  The 0C summary, read at fixed offsets, can shift (BE9441 read 0 and
-0.0, bench #4) -- and a shifted value can look plausible and pass the
impossible-value guard.  So the row now takes the file's channel peaks and
vector sum.

Only when the unit's settings confirm Normal range: the file reader computes
every peak as if the range were Normal (_GEO_SENSITIVE_FS_INS is defined but
unused), so a Sensitive unit's file peaks are 8x off (the checker's 33
waveforms).  For Sensitive, or a range not read (a monitoring unit's 1A has no
settings), the unit's own peaks stand, as before.  The mic is always the
unit's: the file still reads it as 0.  The 0C peaks remain the download check.

Store consequence: new live downloads only; no backfill, no migration.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
2026-10-31 00:17:57 -04:00
..
2026-02-24 21:19:40 +00:00