Files
seismo-relay/minimateplus
Brian Harrison 32b9d3050c feat: implement SUB 1A (compliance config) read
Adds full support for reading device compliance configuration (2090-byte E5
response) containing record time, trigger/alarm levels, and project strings.

protocol.py:
- Implement read_compliance_config() two-step read (SUB 1A → E5)
- Fixed length 0x082A (2090 bytes)

models.py:
- Add ComplianceConfig dataclass with fields: record_time, sample_rate,
  trigger_level_geo, alarm_level_geo, max_range_geo, project strings
- Add compliance_config field to DeviceInfo

client.py:
- Implement _decode_compliance_config_into() to extract:
  * Record time float at offset +0x28 
  * Trigger/alarm levels per-channel (heuristic parsing) 🔶
  * Project/setup strings from E5 payload
  * Placeholder for sample_rate (location TBD )
- Update connect() to read SUB 1A after SUB 01, cache in device_info
- Add ComplianceConfig to imports

sfm/server.py:
- Add _serialise_compliance_config() JSON encoder
- Include compliance_config in /device/info response
- Updated _serialise_device_info() to output compliance config

Both record_time (at fixed offset 0x28) and project strings are  CONFIRMED
from protocol reference §7.6. Trigger/alarm extraction uses heuristics
pending more detailed field mapping from captured data.

Sample rate remains undiscovered in the E5 payload — likely in the
mystery flags at offset +0x12 or requires a "fast mode" capture.

Co-Authored-By: Claude Sonnet 4.6 <noreply@anthropic.com>
2026-04-01 12:08:43 -04:00
..