seismo-relay/tests/fixtures/decode-checker-10-29-26/R352HFZ7_530H_XML.XML
T
serversdownandClaude Opus 5.5 52809a5310 feat(codec): parse Blastware's _XML.XML event report
The reference for the Series 3 decode checker: scalars and value units,
channels, the job number, the user notes in order under their
operator-edited labels, waveform rows as printed (ragged where channels
end at different lengths) and histogram intervals.  Seven real DL2
events as fixtures, each covering a case the comparison must handle.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01ALX2R8pghDaZuti9U7mEE9
2026-10-29 19:23:43 -04:00

99 lines
3.1 KiB
XML
Executable File

<?xml version="1.0" encoding="UTF-8"?>
<Event>
<FileVersion>8.0</FileVersion>
<EventType>Full Histogram</EventType>
<SerialNumber>BE16352</SerialNumber>
<Version>V 10.72-8.17 MiniMate Plus</Version>
<FileName>R352HFZ7.530H</FileName>
<HistogramStartTime>21:17:27</HistogramStartTime>
<HistogramStartDate>2018-06-04</HistogramStartDate>
<HistogramStopTime>21:17:39</HistogramStopTime>
<HistogramStopDate>2018-06-04</HistogramStopDate>
<Channels>
<Channel>Tran</Channel>
<Channel>Vert</Channel>
<Channel>Long</Channel>
</Channels>
<NumberofIntervals>1.00</NumberofIntervals>
<IntervalSize>1 minute</IntervalSize>
<SampleRate>1024 sps</SampleRate>
<BatteryLevel>6.7 Volts</BatteryLevel>
<Calibration>September 13, 2017 by Instantel</Calibration>
<Units>in/s</Units>
<Project>JV 241 - 1425 Spanlers Mill Rad</Project>
<Client>Walsh Granite JV</Client>
<UserName>Terra-Mechanics Inc- D. Harrison</UserName>
<Seis.Loc>Loc #1 - 1425 Spanlers Mill Rd</Seis.Loc>
<GeoRange>
<Value>10.000</Value>
<Units>in/s</Units>
</GeoRange>
<TranPPV>
<Value>0.355</Value>
<Units>in/s</Units>
</TranPPV>
<VertPPV>
<Value>2.475</Value>
<Units>in/s</Units>
</VertPPV>
<LongPPV>
<Value>0.770</Value>
<Units>in/s</Units>
</LongPPV>
<TranZCFreq>
<Value>73</Value>
<Units>Hz</Units>
</TranZCFreq>
<VertZCFreq>
<Value>30</Value>
<Units>Hz</Units>
</VertZCFreq>
<LongZCFreq>
<Value>24</Value>
<Units>Hz</Units>
</LongZCFreq>
<TranPeakTime>21:17:39</TranPeakTime>
<TranPeakDate>2018-06-04</TranPeakDate>
<VertPeakTime>21:17:39</VertPeakTime>
<VertPeakDate>2018-06-04</VertPeakDate>
<LongPeakTime>21:17:39</LongPeakTime>
<LongPeakDate>2018-06-04</LongPeakDate>
<PeakVectorSum>
<Value>2.552</Value>
<Units>in/s</Units>
</PeakVectorSum>
<PeakVectorSumTime>21:17:39</PeakVectorSumTime>
<PeakVectorSumDate>2018-06-04</PeakVectorSumDate>
<TranTestFreq>7.5 Hz.</TranTestFreq>
<TranTestRatio>3.7</TranTestRatio>
<TranTestResults>Passed</TranTestResults>
<VertTestFreq>7.4 Hz.</VertTestFreq>
<VertTestRatio>3.6</VertTestRatio>
<VertTestResults>Passed</VertTestResults>
<LongTestFreq>7.6 Hz.</LongTestFreq>
<LongTestRatio>3.6</LongTestRatio>
<LongTestResults>Passed</LongTestResults>
<UsbSummaryChannels>
</UsbSummaryChannels>
<MonitorLog>2018-06-04 21:17:26 - 2018-06-04 21:17:39 &quot;Event Recorded Modem Exit&quot;</MonitorLog>
<HistogramData>
<HistogramDataColumnTitle>
<ColumnTitle> Tran Peak in/s </ColumnTitle>
<ColumnTitle> Tran Freq Hz </ColumnTitle>
<ColumnTitle> Vert Peak in/s </ColumnTitle>
<ColumnTitle> Vert Freq Hz </ColumnTitle>
<ColumnTitle> Long Peak in/s </ColumnTitle>
<ColumnTitle> Long Freq Hz </ColumnTitle>
<ColumnTitle> Geo PVS in/s </ColumnTitle>
</HistogramDataColumnTitle>
<HistogramDataIntervals>
<Time>2018-06-04 21:17:39</Time>
<Row>
<Cell>0.355</Cell><Cell>73</Cell><Cell>2.475</Cell><Cell>30</Cell><Cell>0.770</Cell><Cell>24</Cell><Cell>2.552</Cell></Row>
</HistogramDataIntervals>
</HistogramData>
<HistogramDataUsbChannels>
</HistogramDataUsbChannels>
</Event>