- minimateplus.protocol: call_home_enabled(raw) reads byte 5 of the UNESCAPED
0x2C payload (0x01 on / 0x00 off, measured 2026-04-20; anything else None --
bench finding #1's lesson: an escaped byte before it would move the raw
index); call_home_image(raw, enabled) is write_image's N + 2 image with byte 5
set and everything else as read, refusing a byte 5 never measured.
- MiniMateClient.read_call_home_raw() / write_call_home_image(image) (0x7E then
0x7F, each ack checked, never retried).
- Series3Adapter.call_home_state (wake, then 0x2C; no serial read, like status)
and change_call_home: the shared change core with a connect() identity check,
state 'enabled' / 'disabled' / 'unknown(0xNN)' (unknown sends nothing), the
plan showing both exact frames, a snapshot of both unescaped images.
- S3_CALL_HOME_FRAME_VERIFIED = False: a live change is refused (501) before any
connection until the frame is reproduced from Blastware's (next commit).
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44