One lost 1F reply made the list return 1 of 3 events as a 200, and on a
download gave a false 404. The list also ran on the 120 s download
timeout, so each lost reply stalled the walk 120 s with the unit locked.
- get_events() strict mode (headers_only, or only_key): a lost 0A reply,
a lost 1F(browse) reply on the success path and on the partial-record
path all re-raise their ProtocolError; a 1F that hands back a key
already walked raises ProtocolError("event chain did not advance ...").
Legacy calls (none of the new options) behave exactly as before --
pinned by tests of the same three faults under get_events().
- Series3Adapter.list_events runs on the default timeout (10 s on TCP);
download_event keeps 120 s.
- FakeProto gains optional lost-reply injection; its default is unchanged.
The repeat-key guard sits at the loop head, which is reached only for a
non-null key -- equivalent to checking each 1F's key, in one place.
Read-only; nothing new on the wire. No codec, store or DB change.
Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
Claude-Session: https://claude.ai/code/session_01SyJ2ip3Krb6dtdv2cXua44
222 lines
10 KiB
Python
222 lines
10 KiB
Python
"""Series-3 adapter. Connect-per-request, as SFM has always done for
|
|
MiniMates -- a held session waits for the bench test in the spec."""
|
|
from __future__ import annotations
|
|
|
|
import datetime
|
|
import logging
|
|
import struct
|
|
from typing import Any, Callable, Optional
|
|
|
|
from minimateplus import MiniMateClient
|
|
from minimateplus.blastware_file import blastware_filename
|
|
from minimateplus.transport import TcpTransport
|
|
|
|
from .errors import DeviceError, EventNotFound, MalformedReply, NoAnswer, StaleEvent, WrongUnit, translate
|
|
from .events import iso_of, make_event_id, stamp_of
|
|
from .models import DownloadedEvent, EventList, EventRef, UnitAddress, UnitInfo, UnitSettings, UnitStatus
|
|
|
|
log = logging.getLogger("sfm.device_access")
|
|
|
|
S3_DEFAULT_BAUD = 38400
|
|
S3_MODES = {0x00: "Single Shot", 0x01: "Continuous", 0x03: "Histogram", 0x04: "Histogram + Continuous"}
|
|
|
|
|
|
S3_EVENT_TIMEOUT = 120.0 # what the legacy event-download routes use
|
|
|
|
|
|
def default_s3_client_factory(address: UnitAddress, timeout: Optional[float] = None) -> MiniMateClient:
|
|
if address.host:
|
|
return MiniMateClient(transport=TcpTransport(address.host, port=address.tcp_port),
|
|
timeout=10.0 if timeout is None else timeout)
|
|
if timeout is None:
|
|
return MiniMateClient(address.port, address.baud or S3_DEFAULT_BAUD)
|
|
return MiniMateClient(address.port, address.baud or S3_DEFAULT_BAUD, timeout=timeout)
|
|
|
|
|
|
def _close(client: Any) -> None:
|
|
try:
|
|
client.close()
|
|
except Exception: # noqa: BLE001
|
|
log.debug("close failed", exc_info=True)
|
|
|
|
|
|
def _s3_dt(ev: Any) -> Optional[datetime.datetime]:
|
|
ts = getattr(ev, "timestamp", None)
|
|
if ts is None or ts.hour is None:
|
|
return None
|
|
try:
|
|
return datetime.datetime(ts.year, ts.month, ts.day, ts.hour, ts.minute, ts.second)
|
|
except (TypeError, ValueError):
|
|
return None
|
|
|
|
|
|
def _s3_filename(ev: Any, serial: str) -> Optional[str]:
|
|
try:
|
|
return blastware_filename(ev, serial)
|
|
except Exception: # noqa: BLE001
|
|
return None
|
|
|
|
|
|
def _s3_ref(ev: Any, serial: str) -> EventRef:
|
|
dt = _s3_dt(ev)
|
|
pv = ev.peak_values
|
|
peaks = {}
|
|
if pv is not None:
|
|
peaks = {k: v for k, v in (("tran", pv.tran), ("vert", pv.vert), ("long", pv.long))
|
|
if v is not None}
|
|
return EventRef(
|
|
event_id=make_event_id(serial, ev._waveform_key, stamp_of(dt)),
|
|
serial=serial, series=3, index=ev.index, timestamp=iso_of(dt),
|
|
record_type=ev.record_type.lower() if ev.record_type else None,
|
|
peak_vector_sum_ips=pv.peak_vector_sum if pv is not None else None,
|
|
peaks_ips=peaks, filename=_s3_filename(ev, serial),
|
|
detail={"mic_psi": pv.micl if pv is not None else None},
|
|
)
|
|
|
|
|
|
class Series3Adapter:
|
|
def __init__(self, client_factory: Callable[..., Any] = default_s3_client_factory) -> None:
|
|
self._factory = client_factory
|
|
|
|
def _run(self, address: UnitAddress, fn: Callable[[Any], Any], timeout: Optional[float] = None) -> Any:
|
|
def attempt() -> Any:
|
|
client = self._factory(address) if timeout is None else self._factory(address, timeout=timeout)
|
|
try:
|
|
client.open()
|
|
except Exception as exc:
|
|
_close(client)
|
|
raise translate(exc, connecting=True) from exc
|
|
try:
|
|
return fn(client)
|
|
except DeviceError:
|
|
raise
|
|
except Exception as exc:
|
|
raise translate(exc, connecting=False) from exc
|
|
finally:
|
|
_close(client)
|
|
|
|
try:
|
|
return attempt()
|
|
except NoAnswer:
|
|
# A MiniMate that has just had its serial lines asserted can take
|
|
# 5-10 s to boot, and shows it as silence; one retry covers it. TCP
|
|
# only -- on a serial cable a silence is a real fault. Narrower than
|
|
# server._run_with_retry (any protocol error): retrying a
|
|
# MalformedReply would also retry "no settings block", which a
|
|
# reconnect cannot fix.
|
|
if not address.host:
|
|
raise
|
|
log.info("Series 3 at %s: no clean answer, retrying once (unit may be cold)", address.key)
|
|
return attempt()
|
|
|
|
@staticmethod
|
|
def _check(serial_reported: str, serial: str, address: UnitAddress) -> None:
|
|
if (serial_reported or "").strip().upper() != serial:
|
|
raise WrongUnit(f"asked for {serial} but {serial_reported} answered at {address.key}")
|
|
|
|
def identify(self, address: UnitAddress, serial: str) -> UnitInfo:
|
|
def op(client: Any) -> UnitInfo:
|
|
info = client.connect()
|
|
self._check(info.serial, serial, address)
|
|
cc = info.compliance_config
|
|
return UnitInfo(
|
|
serial=info.serial, series=3, model=info.model, firmware=info.firmware_version,
|
|
monitoring=None, active_setup=cc.setup_name if cc else None,
|
|
detail={"manufacturer": info.manufacturer, "dsp_version": info.dsp_version},
|
|
)
|
|
return self._run(address, op)
|
|
|
|
def status(self, address: UnitAddress, serial: str) -> UnitStatus:
|
|
def op(client: Any) -> UnitStatus:
|
|
client.poll()
|
|
ms = client.get_monitor_status()
|
|
return UnitStatus(
|
|
serial=serial, series=3, monitoring=ms.is_monitoring,
|
|
battery_volts=round(ms.battery_v, 2) if ms.battery_v is not None else None,
|
|
memory_total_bytes=ms.memory_total, memory_free_bytes=ms.memory_free,
|
|
device_time=None, event_count=None,
|
|
# Series 3 status reads no serial, so the serial shown is the one requested, not one the unit reported.
|
|
detail={"serial_verified": False},
|
|
)
|
|
return self._run(address, op)
|
|
|
|
def settings(self, address: UnitAddress, serial: str) -> UnitSettings:
|
|
def op(client: Any) -> UnitSettings:
|
|
info = client.connect()
|
|
self._check(info.serial, serial, address)
|
|
cc = info.compliance_config
|
|
if cc is None:
|
|
raise MalformedReply("could not read the unit's settings (SUB 0x1A)")
|
|
mode = None
|
|
if cc.recording_mode is not None:
|
|
mode = S3_MODES.get(cc.recording_mode, f"unknown (0x{cc.recording_mode:02x})")
|
|
notes = {
|
|
label: value for label, value in (
|
|
("Project", cc.project), ("Client", cc.client), ("User Name", cc.operator),
|
|
("Seis Loc", cc.sensor_location), ("Extended Notes", cc.notes),
|
|
) if value is not None
|
|
}
|
|
return UnitSettings(
|
|
serial=info.serial, series=3, setup_name=cc.setup_name, record_mode=mode,
|
|
sample_rate=cc.sample_rate, record_time_s=cc.record_time,
|
|
histogram_interval_s=cc.histogram_interval_sec, geo_trigger_ips=cc.trigger_level_geo,
|
|
notes=notes,
|
|
detail={"record_mode_code": cc.recording_mode, "alarm_level_geo": cc.alarm_level_geo,
|
|
"geo_range": cc.geo_range},
|
|
)
|
|
return self._run(address, op)
|
|
|
|
def list_events(self, address: UnitAddress, serial: str) -> EventList:
|
|
def op(client: Any) -> EventList:
|
|
info = client.connect()
|
|
self._check(info.serial, serial, address)
|
|
return EventList(serial=serial, series=3,
|
|
events=[_s3_ref(ev, serial) for ev in client.list_event_headers()])
|
|
# The default timeout: a header walk is small replies only, so a lost
|
|
# one costs 10 s (TCP) with the unit locked, not 120 s.
|
|
return self._run(address, op)
|
|
|
|
def download_event(self, address: UnitAddress, serial: str, key: bytes,
|
|
stamp: Optional[str]) -> DownloadedEvent:
|
|
# The walk compares this with the target's 0C and, on a mismatch, sends
|
|
# no 5A: a stale id costs a header walk, not a full download of the
|
|
# wrong event.
|
|
iso = datetime.datetime.strptime(stamp, "%Y%m%d%H%M%S").isoformat() if stamp is not None else None
|
|
|
|
def op(client: Any) -> DownloadedEvent:
|
|
info = client.connect()
|
|
self._check(info.serial, serial, address)
|
|
try:
|
|
ev = client.download_event_by_key(key, expected_timestamp=iso)
|
|
except struct.error as exc:
|
|
# Inferred, not measured here: the known 5A page bug. An event past the unit's
|
|
# first 64 KB drives TERM's offset negative, and struct.pack rejects it
|
|
# (seismo-relay CLAUDE.md, "KNOWN BUG").
|
|
raise MalformedReply(
|
|
f"event {key.hex()}: its download could not be assembled ({exc}) -- most "
|
|
"likely the known bug with events past the unit's first 64 KB; not saved"
|
|
) from exc
|
|
if ev is None:
|
|
raise EventNotFound(f"no event {key.hex()} on {serial} -- list the events again")
|
|
found = stamp_of(_s3_dt(ev))
|
|
if stamp is not None and found is None:
|
|
raise MalformedReply(
|
|
f"could not read event {key.hex()}'s record (0C) to confirm it is the one "
|
|
"listed -- not downloaded; try again")
|
|
if stamp is not None and found != stamp:
|
|
raise StaleEvent(
|
|
f"the event at {key.hex()} on {serial} is from {found}, not {stamp} -- "
|
|
"the unit was erased or wrapped since the list was read; list again")
|
|
if not ev._a5_frames:
|
|
raise MalformedReply(f"event {key.hex()}: no waveform data received (the 5A download failed)")
|
|
filename = _s3_filename(ev, serial)
|
|
if filename is None:
|
|
raise MalformedReply(f"event {key.hex()} has no usable timestamp, so it cannot be named or stored")
|
|
return DownloadedEvent(
|
|
event_id=make_event_id(serial, key, found), serial=serial, series=3,
|
|
filename=filename, verified=None, event=ev, a5_frames=ev._a5_frames,
|
|
compliance=info.compliance_config, timestamp=_s3_dt(ev),
|
|
detail={"a5_frames": len(ev._a5_frames)},
|
|
)
|
|
return self._run(address, op, timeout=S3_EVENT_TIMEOUT)
|